Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 228

The DOI matches its Crossref record.

Non-invasive estimation of hyperthermia temperatures with ultrasound

Open access
Arthur, R. M., Straube, W. L., Trobaugh, J. W., Moros, E. G. · 2005 · International Journal of Hyperthermia

Abstract

Ultrasound is an attractive modality for temperature monitoring because it is non-ionizing, convenient, inexpensive and has relatively simple signal processing requirements. This modality may be useful for temperature estimation if a temperature-dependent ultrasonic parameter can be identified, measured and calibrated. The most prominent methods for using ultrasound as a non-invasive thermometer exploit either (1) echo shifts due to changes in tissue thermal expansion and speed of sound (SOS), (2) variation in the attenuation coefficient or (3) change in backscattered energy from tissue inhomogeneities. The use of echo shifts has received the most attention in the last decade. By tracking scattering volumes and measuring the time shift of received echoes, investigators have been able to predict the temperature from a region of interest both theoretically and experimentally in phantoms, in isolated tissue regions in vitro and preliminary in vivo studies. A limitation of this method for general temperature monitoring is that prior knowledge of both SOS and thermal-expansion coefficients is necessary. Acoustic attenuation is dependent on temperature, but with significant changes occurring only at temperatures above 50 degrees C, which may lead to its use in thermal ablation therapies. Minimal change in attenuation, however, below this temperature range reduces its attractiveness for use in clinical hyperthermia. Models and measurements of the change in backscattered energy suggest that, over the clinical hyperthermia temperature range, changes in backscattered energy are dependent on the properties of individual scatterers or scattering regions. Calibration of the backscattered energy from different tissue regions is an important goal of this approach. All methods must be able to cope with motion of the image features on which temperature estimates are based. A crucial step in identifying a viable ultrasonic approach to temperature estimation is its performance during in vivo tests.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1080/02656730500159103

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 228

Metadata

Authors
Arthur, R. M., Straube, W. L., Trobaugh, J. W., & Moros, E. G.
Venue
International Journal of Hyperthermia
Published
2005-09-01
Volume
21
Issue
6
Pages
589-600
ISSN
  • 0265-6736 (ISSN-L)
  • 1464-5157
OpenAlex
W2159456079
Cited by
228
References
0
FWCI
6.75
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Non-invasive estimation of hyperthermia temperatures with ultrasound. https://app.cochat.ai/papers/10.1080/02656730500159103
The paper
Arthur, R. M., Straube, W. L., Trobaugh, J. W., & Moros, E. G. (2005). Non-invasive estimation of hyperthermia temperatures with ultrasound. International Journal of Hyperthermia. https://doi.org/10.1080/02656730500159103

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.