The DOI matches its Crossref record.
High intensity focused ultrasound: Physical principles and devices
Open accessAbstract
High intensity focused ultrasound (HIFU) is gaining rapid clinical acceptance as a treatment modality enabling non-invasive tissue heating and ablation for numerous applications. HIFU treatments are usually carried out in a single session, often as a day case procedure, with the patient either fully conscious, lightly sedated or under light general anaesthesia. A major advantage of HIFU over other thermal ablation techniques is that there is no necessity for the transcutaneous insertion of probes into the target tissue. The high powered focused beams employed are generated from sources placed either outside the body (for treatment of tumours of the liver, kidney, breast, uterus, pancreas and bone) or in the rectum (for treatment of the prostate), and are designed to enable rapid heating of a target tissue volume, while leaving tissue in the ultrasound propagation path relatively unaffected. Given the wide-ranging applicability of HIFU, numerous extra-corporeal, transrectal and interstitial devices have been designed to optimise application-specific treatment delivery. Their principle of operation is described here, alongside an overview of the physical mechanisms governing HIFU propagation and HIFU-induced heating. Present methods of characterising HIFU fields and of quantifying HIFU exposure and its associated effects are also addressed.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Medical ultrasound: imaging of soft tissue strain and elasticity
Wells, P. N. T., & Liang, H.-D. (2011) · Journal of The Royal Society Interface · doi:10.1098/rsif.2011.0054 · Cited by 538
Applications of Acoustics and Cavitation to Noninvasive Therapy and Drug Delivery
Coussios, C. C., & Roy, R. A. (2008) · Annual Review of Fluid Mechanics · doi:10.1146/annurev.fluid.40.111406.102116 · Cited by 532
Self-citationIzadifar, Z., Izadifar, Z., Chapman, D., & Babyn, P. (2020) · Journal of Clinical Medicine · doi:10.3390/jcm9020460 · Cited by 457
Bai, Y., Luo, X., Li, Q., Yin, N., Fu, X., Zhang, H., & Qi, H. (2016) · Ultrasound in Obstetrics & Gynecology · doi:10.1002/uog.14867 · Cited by 33
Metadata
- Authors
- ter Haar, >., & Coussios, C.
- Venue
- International Journal of Hyperthermia
- Publisher
- Informa UK Limited
- Published
- 2007-01-01
- Volume
- 23
- Issue
- 2
- Pages
- 89-104
- ISSN
- 0265-6736 (ISSN-L)
- 1464-5157
- OpenAlex
- W2048944905
- Cited by
- 805
- References
- 0
- FWCI
- 15.77
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: High intensity focused ultrasound: Physical principles and devices. https://app.cochat.ai/papers/10.1080/02656730601186138
- The paper
- ter Haar, >., & Coussios, C. (2007). High intensity focused ultrasound: Physical principles and devices. International Journal of Hyperthermia. https://doi.org/10.1080/02656730601186138
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.