The Relationships Among Critical Power Determined From a 3-Min All-Out Test, Respiratory Compensation Point, Gas Exchange Threshold, and Ventilatory Threshold
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
PURPOSE: Critical power (CP) from the 3-min test was compared to the power outputs associated with thresholds determined from gas exchange parameters that have been used to demarcate the exercise-intensity domains including the respiratory compensation point (RCP), gas exchange threshold (GET), and ventilatory threshold (VT). METHOD: Twenty-eight participants performed an incremental-cycle ergometer test to exhaustion. The VT was determined from the relationship between the ventilatory equivalent for oxygen uptake (VE/VO2) versus VO2 and the GET was determined using the V-slope method (VCO2 vs. VO2). The RCP was identified from the VE-versus-VCO2 relationship. CP was the average power output during the last 30 s of the 3-min all-out test. Linear regression was used to determine the power outputs associated with the RCP, GET, and VT, as well as the VO2 associated with CP. Mean differences among the associated power outputs, percent VO2 peak, and percent peak power output for the GET, VT, RCP, and CP were analyzed using separate one-way repeated-measures analyses of variance. RESULTS: There were no significant differences between CP (187 +/- 47W) and the power output associated with RCP (190 +/- 49W) or between the power outputs associated with GET (139 +/- 37W) and VT (145 +/- 37W). The power outputs associated with GET and VT, however, were significantly less than were those at CP and associated with RCRP. CONCLUSIONS: These findings suggest CP and RCP demarcate the heavy from severe exercise-intensity domain and result from a different mechanism of fatigue than that of GET and VT, possibly hyperkalemia.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A new method for detecting anaerobic threshold by gas exchange
Beaver, W. L., Wasserman, K., & Whipp, B. J. (1986) · Journal of Applied Physiology · doi:10.1152/jappl.1986.60.6.2020 · Cited by 4,103
Eckerson, J. M., Stout, J. R., Moore, G. A., Stone, N. J., Iwan, K. A., Gebauer, A. N., & Ginsberg, R. (2005) · The Journal of Strength and Conditioning Research · doi:10.1519/r-16924.1 · Cited by 50
Cited by
An Examination and Critique of Current Methods to Determine Exercise Intensity
Jamnick, N. A., Pettitt, R. W., Granata, C., Pyne, D. B., & Bishop, D. J. (2020) · Sports Medicine · doi:10.1007/s40279-020-01322-8 · Cited by 424
Exercise Intensity Thresholds: Identifying the Boundaries of Sustainable Performance
KEIR, D. A., FONTANA, F. Y., ROBERTSON, T. C., MURIAS, J. M., PATERSON, D. H., KOWALCHUK, J. M., & POGLIAGHI, S. (2015) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0000000000000613 · Cited by 205
Exercise Thresholds on Trial: Are They Really Equivalent?
CAEN, K., VERMEIRE, K., BOURGOIS, J. G., & BOONE, J. (2018) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0000000000001547 · Cited by 42
Metadata
- Authors
- Bergstrom, H. C., Housh, T. J., Zuniga, J. M., Traylor, D. A., Camic, C. L., Lewis, R. W., Schmidt, R. J., & Johnson, G. O.
- Venue
- Research Quarterly for Exercise and Sport
- Publisher
- Informa UK Limited
- Published
- 2013-06
- Volume
- 84
- Issue
- 2
- Pages
- 232-238
- ISSN
- 0034-5377 (ISSN-L)
- 0270-1367
- 2168-3824
- OpenAlex
- W2038950917
- Cited by
- 54
- References
- 2
- FWCI
- 10.20
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: The Relationships Among Critical Power Determined From a 3-Min All-Out Test, Respiratory Compensation Point, Gas Exchange Threshold, and Ventilatory Threshold. https://app.cochat.ai/papers/10.1080/02701367.2013.784723
- The paper
- Bergstrom, H. C., Housh, T. J., Zuniga, J. M., Traylor, D. A., Camic, C. L., Lewis, R. W., Schmidt, R. J., & Johnson, G. O. (2013). The Relationships Among Critical Power Determined From a 3-Min All-Out Test, Respiratory Compensation Point, Gas Exchange Threshold, and Ventilatory Threshold. Research Quarterly for Exercise and Sport. https://doi.org/10.1080/02701367.2013.784723
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.