Penetration of Ambient Fine Particles into the Indoor Environment
Open accessThe DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
Several recent studies have indicated significant health risks associated with exposure to fine particles as measured outdoors. However, much of the exposure is believed to have occurred indoors. Consequently, there is considerable interest in the relationship between indoor and outdoor fine particles. This paper describes some results from a study in which the processes of particle removal from infiltrating air by building envelopes are simulated in a chamber. The chamber consists of two compartments, each having a volume of 19 m3. Particles with aerodynamic diameters in the range of 0.05 to 5
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Fuchs, N. A., Daisley, R. E., Fuchs, M., & Davies, C. N. (1964) · Cited by 2,278
Deposition, resuspension, and penetration of particles within a residence
Thatcher, T. (1995) · Atmospheric Environment · doi:10.1016/1352-2310(95)00016-r · Cited by 859 · cited 3×
“While the Thatcher and Layton study did focus on penetration, it is a study of about two weeks in only one house and, consequently, is not de nitive. While it seems counterintuitive that all particles, especially the large and very small ones, would readily pass through the small openings in a building shell, little…”
BackgroundÖzkaynak, H., Xue, J., Spengler, J. D., Wallace, L. A., Pellizzari, E. D., & Jenkins, P. (1996) · PubMed · Cited by 476
Simplified calculation of aerosol penetration through channels and tubes
Lee, K. W., & Gieseke, J. A. (1980) · Atmospheric Environment (1967) · doi:10.1016/0004-6981(80)90039-6 · Cited by 31 · cited 1×
“Lee and Gieseke (1980) developed the following simple expression to describe the penetration of particles through a parallel plate channel when deposition is dominated by diffusion: Pd D exp ³ ¡ 1:967DL h2u ´ ; [8] where Pd is the penetration associated with particle diffusion, D D (kT C )=(3¼¹d )…”
Background
Cited by
Chen, C., & Zhao, B. (2011) · Atmospheric Environment · doi:10.1016/j.atmosenv.2010.09.048 · Cited by 972
Nazaroff, W. W. (2004) · Indoor Air · doi:10.1111/j.1600-0668.2004.00286.x · Cited by 639
Indoor particulate matter of outdoor origin: Importance of size-dependent removal mechanisms
Riley, W. J., McKone, T. E., Lai, A. C. K., & Nazaroff, W. W. (2002) · Environmental Science & Technology · doi:10.1021/es010723y · Cited by 417
Effects of room furnishings and air speed on particle deposition rates indoors
Thatcher, T. L., Lai, A. C. K., Moreno-Jackson, R., Sextro, R. G., & Nazaroff, W. W. (2002) · Atmospheric Environment · doi:10.1016/s1352-2310(02)00157-7 · Cited by 416
Source Strengths for Indoor Human Activities that Resuspend Particulate Matter
Ferro, A. R., Kopperud, R. J., & Hildemann, L. M. (2004) · Environmental Science & Technology · doi:10.1021/es0263893 · Cited by 378
Metadata
- Authors
- Mosley, R. B., Greenwell, D. J., Sparks, L. E., Guo, Z., Tucker, W. G., Fortmann, R., & Whitfield, C.
- Venue
- Aerosol Science and Technology
- Publisher
- Informa UK Limited
- Published
- 2001-01
- Volume
- 34
- Issue
- 1
- Pages
- 127-136
- ISSN
- 0278-6826 (ISSN-L)
- 1521-7388
- OpenAlex
- W2144661273
- Cited by
- 174
- References
- 4
- FWCI
- 9.20
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.