Capture of Viral Particles in Soft X-Ray–Enhanced Corona Systems: Charge Distribution and Transport Characteristics
Open accessThe DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
The charge distribution of airborne MS2 bacteriophage nanoparticles and the efficiency of electrical-mobility–based capture mechanisms with bipolar charging were studied. MS2 virions form large agglomerated particles in a suspension. The average charge on airborne MS2 virions can be as high as one unit charge (negatively charged). The application of both soft X-ray irradiation and alpha rays from a Po-210 bipolar charger was shown to not only reduce the average charge on MS2 virion particles but also partially fragment the larger MS2 virion agglomerates, thereby increasing the number of ultrafine MS2 virion particles. A cylindrical electrostatic precipitator with a mounted soft X-ray emitter was used to determine the effectiveness of electrical capture methods for virus particles. At low applied voltages, it was found that the capture efficiency of ultrafine virus particles can be increased by applying in situ soft X-ray irradiation with electrostatic precipitation. It has also been shown that in the presence of both a positive and negative corona, virus particles are readily captured with log removal values exceeding 4. The unit developed and demonstrated in this work is a compact, low-pressure drop system that can be readily mounted in ventilation ducts or air supply systems to remove ultrafine particles such as viruses.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The Refined Structure of Bacteriophage MS2 at 2·8 Å Resolution
Golmohammadi, R., Valegård, K., Fridborg, K., & Liljas, L. (1993) · Journal of Molecular Biology · doi:10.1006/jmbi.1993.1616 · Cited by 303
Cited by
Nanoparticles and the Environment
Biswas, P., & Wu, C.-Y. (2005) · Journal of the Air & Waste Management Association · doi:10.1080/10473289.2005.10464656 · Cited by 793
Self-citationBałazy, A., Toivola, M., Adhikari, A., Sivasubramani, S. K., Reponen, T., & Grinshpun, S. A. (2006) · American Journal of Infection Control · doi:10.1016/j.ajic.2005.08.018 · Cited by 376
“For instance, Hogan et al referred to the agglomerates larger than 200 nm seen on the SEM images obtained from a liquid viral suspension.(26) It should be acknowledged, however, Fig 2.”
BackgroundBioaerosol sampling: Classical approaches, advances, and perspectives
Mainelis, G. (2020) · Aerosol Science and Technology · doi:10.1080/02786826.2019.1671950 · Cited by 229
“Efficient capture of viruses was achieved using ESPs with a novel charging system (Hogan, Lee, and Biswas 2004; Kettleson et al. 2009), including for the use of plaque assays and qPCR.”
MethodHogan, C. J., Kettleson, E. M., Lee, M.-H., Ramaswami, B., Angenent, L. T., & Biswas, P. (2005) · Journal of Applied Microbiology · doi:10.1111/j.1365-2672.2005.02720.x · Cited by 223
Self-citationAssessment of iodine-treated filter media for removal and inactivation of MS2 bacteriophage aerosols
Lee, J.-H., Wu, C.-Y., Lee, C. N., Anwar, D., Wysocki, K. M., Lundgren, D. A., Farrah, S., Wander, J., & Heimbuch, B. K. (2009) · Journal of Applied Microbiology · doi:10.1111/j.1365-2672.2009.04375.x · Cited by 33
“MS2 aggregation generated from the nebulizer, which is caused by hydrophobic interactions between neighbouring protein capsids, has been observed by previous studies (Hogan et al. 2004; Balazy et al. 2006).”
Result
Metadata
- Authors
- Hogan, C. J., Lee, M.-H., & Biswas, P.
- Venue
- Aerosol Science and Technology
- Publisher
- Informa UK Limited
- Published
- 2004-05
- Volume
- 38
- Issue
- 5
- Pages
- 475-486
- ISSN
- 0278-6826 (ISSN-L)
- 1521-7388
- OpenAlex
- W2011771648
- Cited by
- 73
- References
- 1
- FWCI
- 3.92
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.