Filtration Efficiency of Aerosol Particles Below 20 Nanometers
Open accessThe DOI matches its Crossref record.
Abstract
The current work examines the filtration of both charged and uncharged NaCl nanoparticles in the size range of 2.5–20 nm on grounded metal filters and meshes, and on plastic mesh. The methodology thus allows electrostatic and other effects to be differentiated from true thermal rebound effects (Wang and Kasper 1991). The work also compares measurements under identical conditions made with a number of different condensation particle counters, and a number of different experimental methodologies, in order to allow exclusion of certain measurement errors from the results. It was found that even for particle sizes as small as 2.5 nm there was no measurable deviation from the classical single-fiber-efficiency theory. This conflicts with recently published work (Balazy et al. 2004) which claimed that the thermal bounce of nanometer sized aerosol particles begins to occur at a much larger particle size than previously thought. However, peculiarities or artifacts in CPC counting efficiency at small particle sizes were found during experiments which could account for such observations reported in previous work.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Nanoparticle filtration by electrospun polymer fibers
Yun, K. M., Hogan, C. J., Matsubayashi, Y., Kawabe, M., Iskandar, F., & Okuyama, K. (2007) · Chemical Engineering Science · doi:10.1016/j.ces.2007.06.007 · Cited by 293
Occupational Risk Management of Engineered Nanoparticles
Schulte, P., Geraci, C., Zumwalde, R., Hoover, M., & Kuempel, E. (2008) · Journal of Occupational and Environmental Hygiene · doi:10.1080/15459620801907840 · Cited by 247
“(35) Scientific studies, to date, on the aerosol behavior of nanoparticles in filtration systems have shown that nanoparticles follow these established laws.(36,37) Nanoparticles have low inertia and will generally follow the surrounding airflow.”
BackgroundEnvironmental and Human Health Risks of Aerosolized Silver Nanoparticles
Quadros, M. E., & Marr, L. C. (2010) · Journal of the Air & Waste Management Association · doi:10.3155/1047-3289.60.7.770 · Cited by 233
Penetration of 4.5nm to aerosol particles through fibrous filters
Huang, S.-H., Chen, C.-W., Chang, C.-P., Lai, C.-Y., & Chen, C.-C. (2007) · Journal of Aerosol Science · doi:10.1016/j.jaerosci.2007.05.007 · Cited by 108
MOSTOFI, R., WANG, B., HAGHIGHAT, F., BAHLOUL, A., & JAIME, L. (2010) · Industrial Health · doi:10.2486/indhealth.48.296 · Cited by 58
Metadata
- Authors
- Heim, M., Mullins, B. J., Wild, M., Meyer, J., & Kasper, G.
- Venue
- Aerosol Science and Technology
- Publisher
- Informa UK Limited
- Published
- 2005-08
- Volume
- 39
- Issue
- 8
- Pages
- 782-789
- ISSN
- 0278-6826 (ISSN-L)
- 1521-7388
- OpenAlex
- W2020136441
- Cited by
- 88
- References
- 0
- FWCI
- 5.40
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Filtration Efficiency of Aerosol Particles Below 20 Nanometers. https://app.cochat.ai/papers/10.1080/02786820500227373
- The paper
- Heim, M., Mullins, B. J., Wild, M., Meyer, J., & Kasper, G. (2005). Filtration Efficiency of Aerosol Particles Below 20 Nanometers. Aerosol Science and Technology. https://doi.org/10.1080/02786820500227373
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.