Penetration of 4.5nm to aerosol particles through fibrous filters
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The increase in PF with flow rate agrees with previous studies and can be explained by greater effect of impaction and interception at higher air velocities.
“This also agrees with previous studies and can be explained by greater effect of impaction and interception that occurs at higher air velocities (Chen et al., 1990;Huang et al., 2007).”
From Large Particle Penetration through N95 Respirator Filters and Facepiece Leaks with Cyclic Flow (2009) · cites this paper as Huang et al., 2007
The trend of decreasing faceseal penetration with increasing particle size and air velocity should be expected as impaction and interception mechanisms dominate, particularly in the supermicrometer size range.
“This trend should be expected as impaction and interception mechanisms dominate with increasing particle size and air velocity, particularly in the supermicrometer size range (Huang et al., 2007).”
From Large Particle Penetration through N95 Respirator Filters and Facepiece Leaks with Cyclic Flow (2009) · cites this paper as Huang et al., 2007
Cites
Electrostatic forces in fibrous filters—a review
Wang, C.-S. (2001) · Powder Technology · doi:10.1016/s0032-5910(01)00307-2 · Cited by 236 · see citing works
Electrostatic Respirator Filter Media: Filter Efficiency and Most Penetrating Particle Size Effects
Martin, S. B., & Moyer, E. S. (2000) · Applied Occupational and Environmental Hygiene · doi:10.1080/10473220050075617 · Cited by 156 · see citing works
Flagged first, then by citations
Cited by
Sorted by citations
Evaluating the Efficacy of Cloth Facemasks in Reducing Particulate Matter Exposure
Shakya, K. M., Noyes, A., Kallin, R., & Peltier, R. E. (2017) · Journal of Exposure Science & Environmental Epidemiology · doi:10.1038/jes.2016.42 · Cited by 202 · see citing works
(2012) · The Annals of Occupational Hygiene · doi:10.1093/annhyg/mer122 · Cited by 75 · see citing works
He, X., Reponen, T., McKay, R. T., & Grinshpun, S. A. (2013) · Aerosol Science and Technology · doi:10.1080/02786826.2013.829209 · Cited by 64 · see citing works
MOSTOFI, R., WANG, B., HAGHIGHAT, F., BAHLOUL, A., & JAIME, L. (2010) · Industrial Health · doi:10.2486/indhealth.48.296 · Cited by 58 · see citing works
Large Particle Penetration through N95 Respirator Filters and Facepiece Leaks with Cyclic Flow
(2009) · The Annals of Occupational Hygiene · doi:10.1093/annhyg/mep062 · Cited by 42 · see citing works
- Authors
- Huang, S.-H., Chen, C.-W., Chang, C.-P., Lai, C.-Y., & Chen, C.-C.
- Affiliations
- Institute of Labor, Occupational Safety And Health, Ministry of Labor (TW)
- National Taiwan University (TW)
- Corresponding author
- Chen, Chih-Chieh
- Venue
- Journal of Aerosol Science
- Publisher
- Elsevier BV
- Published
- 2007-07
- Volume
- 38
- Issue
- 7
- Pages
- 719-727
- ISSN
- 0021-8502 (ISSN-L)
- OpenAlex
- W1978708196
- Cited by
- 108
- References
- 2
- Citations by year
- 2026: 1 · 2025: 2 · 2024: 3 · 2023: 1 · 2022: 5 · 2021: 6 · 2020: 8 · 2019: 9 · 2018: 4 · 2017: 8 · 2016: 8 · 2015: 9 · 2014: 5 · 2013: 10 · 2012: 8
- FWCI
- 4.46
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Journal of Aerosol Science (publishedVersion)
- Topics
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Aerosol Filtration and Electrostatic Precipitation
- Physical Sciences › Engineering › Computational Mechanics › Cyclone Separators and Fluid Dynamics
- Physical Sciences › Engineering › Ocean Engineering › Particle Dynamics in Fluid Flows
- Keywords
- aerosol penetration, fibrous filters, nanoparticles, submicron particles, particle size distribution, NaCl aerosol, spray drying, differential mobility analyzer, aerodynamic particle sizer
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review