Transmission Efficiency of an Aerodynamic Focusing Lens System: Comparison of Model Calculations and Laboratory Measurements for the Aerodyne Aerosol Mass Spectrometer
Open accessThe DOI matches its Crossref record; 19 of the 19 references it cites were found in a registry or an index.
Abstract
The size-dependent particle transmission efficiency of the aerodynamic lens system used in the Aerodyne Aerosol Mass Spectrometer (AMS) was investigated with computational fluid dynamics (CFD) calculations and experimental measurements. The CFD calculations revealed that the entire lens system, including the aerodynamic lens itself, the critical orifice which defines the operating lens pressure, and a valve assembly, needs to be considered. Previous calculations considered only the aerodynamic lens. The calculations also investigated the effect of operating the lens system at two different sampling pressures, 7.8 × 104 Pa (585 torr) and 1.0 × 105 Pa (760 torr). Experimental measurements of transmission efficiency were performed with size-selected diethyl hexyl sebacate (DEHS), NH4NO3, and NaNO3 particles on three different AMS instruments at two different ambient sampling pressures (7.8 × 104 Pa, 585 torr and 1.0 × 105 Pa, 760 torr). Comparisons of the measurements and the calculations show qualitative agreement, but there are significant deviations which are as yet unexplained. On the small size end (30 nm to 150 nm vacuum aerodynamic diameter), the measured transmission efficiency is lower than predicted. On the large size end (> 350 nm vacuum aerodynamic diameter) the measured transmission efficiency is greater than predicted at 7.8 × 104 Pa (585 torr) and in good agreement with the prediction at 1.0 × 105 Pa (760 torr).
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Atmospheric Chemistry and Physics: From Air Pollution to Climate Change
Seinfeld, J. H., Pandis, S. N., & Noone, K. (1998) · Physics Today · doi:10.1063/1.882420 · Cited by 8,731
Atmospheric chemistry and physics: from air pollution to climate change
(1998) · Choice Reviews Online · doi:10.5860/choice.35-5721 · Cited by 4,944
Canagaratna, M. R., Jayne, J. T., Jimenez, J. L., Allan, J. D., Alfarra, M. R., Zhang, Q., Onasch, T. B., Drewnick, F., Coe, H., Middlebrook, A., et al. (2007) · Mass Spectrometry Reviews · doi:10.1002/mas.20115 · Cited by 1,846
Self-citationDevelopment of an Aerosol Mass Spectrometer for Size and Composition Analysis of Submicron Particles
Jayne, J. T., Leard, D. C., Zhang, X., Davidovits, P., Smith, K. A., Kolb, C. E., & Worsnop, D. R. (2000) · Aerosol Science and Technology · doi:10.1080/027868200410840 · Cited by 1,604
Self-citationDeCarlo, P., Slowik, J., Worsnop, D., Davidovits, P., & Jimenez, J. (2004) · Aerosol Science and Technology · doi:10.1080/02786826.2004.10399461 · Cited by 1,239
Self-citationDispersion and Deposition of Spherical Particles from Point Sources in a Turbulent Channel Flow
Li, A., & Ahmadi, G. (1992) · Aerosol Science and Technology · doi:10.1080/02786829208959550 · Cited by 1,002
An approximation of the bipolar charge distribution for particles in the submicron size range
Wiedensohler, A. (1988) · Journal of Aerosol Science · doi:10.1016/0021-8502(88)90278-9 · Cited by 947
Ambient aerosol sampling using the Aerodyne Aerosol Mass Spectrometer
Jimenez, J. L., Jayne, J. T., Shi, Q., Kolb, C. E., Worsnop, D. R., Yourshaw, I., Seinfeld, J. H., Flagan, R. C., Zhang, X., Smith, K. A., et al. (2003) · Journal of Geophysical Research: Atmospheres · doi:10.1029/2001jd001213 · Cited by 942
Self-citationA review of atmospheric aerosol measurements
McMurry, P. (2000) · Atmospheric Environment · doi:10.1016/s1352-2310(99)00455-0 · Cited by 832
Allan, J. D., Jimenez, J. L., Williams, P. I., Alfarra, M. R., Bower, K. N., Jayne, J. T., Coe, H., & Worsnop, D. R. (2003) · Journal of Geophysical Research: Atmospheres · doi:10.1029/2002jd002358 · Cited by 564
Self-citationGard, E., Mayer, J. E., Morrical, B. D., Dienes, T., Fergenson, D. P., & Prather, K. A. (1997) · Analytical Chemistry · doi:10.1021/ac970540n · Cited by 533
Aerosol mass spectrometer for size and composition analysis of submicron particles
Jayne, J. T., Worsnop, D. R., Kolb, C. E., Leard, D., Davidovits, P., Zhang, X., & Smith, K. A. (1998) · Journal of Aerosol Science · doi:10.1016/s0021-8502(98)00158-x · Cited by 375
Self-citationZhang, Q., Canagaratna, M. R., Jayne, J. T., Worsnop, D. R., & Jimenez, J. (2005) · Journal of Geophysical Research: Atmospheres · doi:10.1029/2004jd004649 · Cited by 331
Self-citationAllan, J. D., Alfarra, M. R., Bower, K. N., Williams, P. I., Gallagher, M. W., Jimenez, J. L., McDonald, A. G., Nemitz, E., Canagaratna, M. R., Jayne, J. T., et al. (2003) · Journal of Geophysical Research: Atmospheres · doi:10.1029/2002jd002359 · Cited by 204
Self-citationSingle Particle Laser Ablation Time-of-Flight Mass Spectrometer: An Introduction to SPLAT
Zelenyuk, A., & Imre, D. G. (2005) · Aerosol Science and Technology · doi:10.1080/027868291009242 · Cited by 173
Allan, J. D., Bower, K. N., Coe, H., Boudries, H., Jayne, J. T., Canagaratna, M. R., Millet, D. B., Goldstein, A. H., Quinn, P. K., Weber, R. J., et al. (2004) · Journal of Geophysical Research Atmospheres · doi:10.1029/2003jd004208 · Cited by 163
Self-citationQuinn, P. K., Bates, T. S., Coffman, D., Onasch, T. B., Worsnop, D. R., Baynard, T., de Gouw, J. A., Goldan, P. D., Kuster, W. C., Williams, E. J., et al. (2006) · Journal of Geophysical Research Atmospheres · doi:10.1029/2006jd007582 · Cited by 127
Self-citationParticle size analysis utilizing grouped data and the log-normal distribution
Raabe, O. G. (1971) · Journal of Aerosol Science · doi:10.1016/0021-8502(71)90054-1 · Cited by 97
Allan, R. P., Ramaswamy, V., & Slingo, A. (2003) · Journal of Geophysical Research Atmospheres · doi:10.1029/2002jd002948 · Cited by 29
Cited by
Canagaratna, M. R., Jayne, J. T., Jimenez, J. L., Allan, J. D., Alfarra, M. R., Zhang, Q., Onasch, T. B., Drewnick, F., Coe, H., Middlebrook, A., et al. (2007) · Mass Spectrometry Reviews · doi:10.1002/mas.20115 · Cited by 1,846
Self-citationMiddlebrook, A. M., Bahreini, R., Jimenez, J. L., & Canagaratna, M. R. (2012) · Aerosol Science and Technology · doi:10.1080/02786826.2011.620041 · Cited by 975
Self-citationNg, N. L., Herndon, S. C., Trimborn, A., Canagaratna, M. R., Croteau, P. L., Onasch, T. B., Sueper, D., Worsnop, D. R., Zhang, Q., Sun, Y. L., et al. (2011) · Aerosol Science and Technology · doi:10.1080/02786826.2011.560211 · Cited by 970
Self-citationElser, M., Huang, R.-J., Wolf, R., Slowik, J. G., Wang, Q., Canonaco, F., Li, G., Bozzetti, C., Daellenbach, K. R., Huang, Y., et al. (2016) · Atmospheric Chemistry and Physics · doi:10.5194/acp-16-3207-2016 · Cited by 389
Matthew, B. M., Middlebrook, A. M., & Onasch, T. B. (2008) · Aerosol Science and Technology · doi:10.1080/02786820802356797 · Cited by 357
Self-citation
Metadata
- Authors
- Liu, P. S. K., Deng, R., Smith, K. A., Williams, L. R., Jayne, J. T., Canagaratna, M. R., Moore, K., Onasch, T. B., Worsnop, D. R., & Deshler, T.
- Venue
- Aerosol Science and Technology
- Publisher
- Informa UK Limited
- Published
- 2007-07-05
- Volume
- 41
- Issue
- 8
- Pages
- 721-733
- ISSN
- 0278-6826 (ISSN-L)
- 1521-7388
- OpenAlex
- W2164557084
- Cited by
- 376
- References
- 19
- FWCI
- 8.67
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.