Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 343

The DOI matches its Crossref record; 31 of the 31 references it cites were found in a registry or an index.

Fine particle mass monitoring with low-cost sensors: Corrections and long-term performance evaluation

Open access
Malings, Carl, Tanzer, Rebecca, Hauryliuk, Aliaksei, Saha, Provat K., Robinson, Allen L., Presto, Albert A., Subramanian, R · 2020 · Aerosol Science and Technology

Abstract

Low-cost fine particle mass (PM2.5) sensors enable dense networks to increase the spatial resolution of air quality monitoring. However, these sensors are affected by environmental factors such as temperature and humidity, which must be accounted for to improve their in-field accuracy. We conduct long-term tests of two low-cost PM2.5 sensors: Met-One NPM and PurpleAir PA-II units. We find a high level of self-consistency within each sensor type after testing 25 NPM and 9 PurpleAir units. We develop corrections for the low-cost sensor measurements to better match regulatory-grade data through collocation with Beta Attenuation Monitors (BAM). The first correction based on a physical model accounts for hygroscopic growth using particle composition and corrects for particle mass below the optical sensor detection limit by collocation with a BAM. A second fully-empirical correction uses linear or quadratic functions of environmental variables. Either model yields comparable improvements over raw measurements. Sensor performance is assessed for two use cases: improving community awareness of air quality with short-term qualitative comparisons of sites and providing long-term quantitative information for health impact studies. For the short-term case, either sensor can provide reasonably accurate concentration information (mean absolute error of ~4 µg/m3) in near-real time. For the long-term case, tested using year-long collocations at one urban background and one near-source site, error in the annual average is reduced below 1 µg/m3. These sensors are thus suitable for supplementing regulatory-grade instruments in sparsely monitored regions and for conducting hotspot mapping to understand air quality variability in urban areas.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1080/02786826.2019.1623863

Cites

31 of 31 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 31 references

Cited by

See all 343

Metadata

Authors
Malings, C., Tanzer, R., Hauryliuk, A., Saha, P. K., Robinson, A. L., Presto, A. A., & Subramanian, R.
Venue
Aerosol Science and Technology
Published
2019-06-10
Volume
54
Issue
2
Pages
160-174
ISSN
  • 0278-6826 (ISSN-L)
  • 1521-7388
OpenAlex
W2906135971
Cited by
343
References
31
FWCI
14.72
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Fine particle mass monitoring with low-cost sensors: Corrections and long-term performance evaluation. https://app.cochat.ai/papers/10.1080/02786826.2019.1623863
The paper
Malings, C., Tanzer, R., Hauryliuk, A., Saha, P. K., Robinson, A. L., Presto, A. A., & Subramanian, R. (2020). Fine particle mass monitoring with low-cost sensors: Corrections and long-term performance evaluation. Aerosol Science and Technology. https://doi.org/10.1080/02786826.2019.1623863

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.