Asbestos in Buildings: The Difficulties of a Reliable Exposure Assessment
The DOI matches its Crossref record; 27 of the 27 references it cites were found in a registry or an index.
Abstract
Based on careful investigations carried out in 12 different buildings with and without friable asbestos containing insulation materials, different ways of exposure assessment are compared. Methods used are visual inspection algorithm, phase-contrast microscopy (PCM), direct reading instruments (FAM, fibrous aerosol monitor), scanning electron microscopy (SEM), and transmission electron microscopy (TEM). This last method was considered as a reference, because the complete size distribution of every type of mineral fiber can be assessed. The advantages and limitations of each method are discussed in the light of the results obtained. Among many others a few relevant findings may be cited: 1) In buildings where no known source of asbestos fibers exists high levels of fibers from unsuspected sources can be found. 2) The resuspension of settled fibers is one of the main sources of exposure and is related to the presence or activities of people in the concerned area. 3) The common belief that a ventilation system in contact with friable asbestos containing material is a major source of indoor pollution was not confirmed here. 4) In some situations all the chrysotile fibers longer than 5 μm were too thin to be seen either by PCM or SEM. 5) The size distribution varies according to the fiber type and the situation. The risk assessment based on a limited number of epidemiologic studies is strongly related to the method by which asbestos exposure is measured and to the relationship between the “old” methods used in the occupational environment and those presently used in nonoccupational situations.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“These results are consistent with published exposure data in indoor air obtained by TEM, indicating a high proportion of SAF; 90 to 100% in most studies [5-9].”
From Quantification of short and long asbestos fibers to assess asbestos exposure: A review of fiber size toxicity (2014) · cites this paper as [7]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Health implications of environmental exposure to asbestos.
McDonald, J. C. (1985) · Environmental Health Perspectives · doi:10.1289/ehp.8562319 · Cited by 143
Biological effects of mineral fibres
(1982) · Environmental Pollution Series A Ecological and Biological · doi:10.1016/0143-1471(82)90110-6 · Cited by 111
Asbestos Exposure —Quantitative Assessment of Risk 1– 3
Hughes, J. M., & Weill, H. (1986) · American Review of Respiratory Disease · doi:10.1164/arrd.1986.133.1.5 · Cited by 109
Exposures and mortality among chrysotile asbestos workers. Part I: Exposure estimates
Dement, J. M., Harris, R. L., Symons, M. J., & Shy, C. M. (1983) · American Journal of Industrial Medicine · doi:10.1002/ajim.4700040303 · Cited by 104
Churg, A., & Wiggs, B. (1986) · American Journal of Industrial Medicine · doi:10.1002/ajim.4700090205 · Cited by 75
Asbestos exposure in a Yale building
Sawyer, R. N. (1977) · Environmental Research · doi:10.1016/0013-9351(77)90013-5 · Cited by 59
Animal experiments on biological effects of mineral fibres.
POTT, F. (1980) · PubMed · Cited by 43
Dust-Fiber Relationships in the Quebec Chrysotile Industry
Gibbs, G. W., & LaChance, M. (1974) · Archives of Environmental Health An International Journal · doi:10.1080/00039896.1974.10666439 · Cited by 35
Development of a prototype fibrous aerosol monitor
LILIENFELD, P., ELTERMAN, P. B., & BARON, P. (1979) · American Industrial Hygiene Association Journal · doi:10.1080/15298667991429598 · Cited by 35
AIRBORNE ASBESTOS CONCENTRATIONS IN BUILDINGS
(1986) · The Annals of Occupational Hygiene · doi:10.1093/annhyg/30.2.185 · Cited by 34
LEVELS OF ASBESTOS AIR POLLUTION IN SOME ENVIRONMENTAL SITUATIONS
Sebastien, P., Billon‐Galland, M., Dufour, G., Gaudichet, A., Bonnaud, G., & Bignon, J. (1979) · Annals of the New York Academy of Sciences · doi:10.1111/j.1749-6632.1979.tb18742.x · Cited by 25
Topographic and size distribution of asbestos bodies in exposed human lungs
Gylseth, B., & Baunan, R. (1981) · Scandinavian Journal of Work Environment & Health · doi:10.5271/sjweh.3111 · Cited by 25
Boehm, G., & Leuschner, R. M. (1987) · Proceedings of the Fourth International Symposium on Polarization Phenomena in Nuclear Reactions · doi:10.1007/978-3-0348-7491-5 · Cited by 25
Snyder, J. G., Virta, R. L., & Segreti, J. M. (1987) · American Industrial Hygiene Association Journal · doi:10.1080/15298668791385066 · Cited by 19
ASBESTOS AND OTHER FIBRE LEVELS IN BUILDINGS
Altree-Williams, S., & PRESTON, J. S. (1985) · The Annals of Occupational Hygiene · doi:10.1093/annhyg/29.3.357 · Cited by 16
Asbestos exposures in Massachusetts public schools
IRVING, K. F., Alexander, R. G., & Bavley, H. (1980) · American Industrial Hygiene Association Journal · doi:10.1080/15298668091424735 · Cited by 16
(1984) · The Annals of Occupational Hygiene · doi:10.1093/annhyg/28.3.333 · Cited by 16
THE EFFECT OF ASPECT RATIO ON FIBER COUNTS: A PRELIMINARY STUDY
Winer, A. A., & Cossette, M. (1979) · Annals of the New York Academy of Sciences · doi:10.1111/j.1749-6632.1979.tb18770.x · Cited by 15
Determination of asbestos fibres in air transmission electron microscopy as a reference method
Steen, D., Guillemin, M. P., Buffat, P., & Litzistorf, G. (1983) · Atmospheric Environment (1967) · doi:10.1016/0004-6981(83)90227-5 · Cited by 14
Self-citationComparison of Methods of Assessing Asbestos Fiber Concentrations
Hwang, C. Y., & Wang, Z. M. (1983) · Archives of Environmental Health An International Journal · doi:10.1080/00039896.1983.10543972 · Cited by 12
RATE OF DECLINE OF ASBESTOS FIBRE CONCENTRATION IN ROOM AIR
Moorcroft, J. S., & Duggan, M. (1984) · The Annals of Occupational Hygiene · doi:10.1093/annhyg/28.4.453 · Cited by 11
(1984) · The Annals of Occupational Hygiene · doi:10.1093/annhyg/28.3.321 · Cited by 8
Iles, P. J., & SHENTON-TAYLOR, T. (1986) · The Annals of Occupational Hygiene · doi:10.1093/annhyg/30.1.77 · Cited by 8
Airborne asbestos in Colorado public schools
Chadwick, D. A., Buchan, R. M., & Beaulieu, H. J. (1985) · Environmental Research · doi:10.1016/0013-9351(85)90002-7 · Cited by 7
An assessment of the Environmental Protection Agency's asbestos hazard evaluation algorithm.
Findley, M., Rose, V. E., Cutter, G., & Windsor, R. A. (1983) · American Journal of Public Health · doi:10.2105/ajph.73.10.1179 · Cited by 7
The Indoor Asbestos Problem: Facts and Questions
Guillemin, M. P., Litzistorf, G., Madelaine, P., Iselin, F., & Buffat, P. (1987) · Proceedings of the Fourth International Symposium on Polarization Phenomena in Nuclear Reactions · doi:10.1007/978-3-0348-7491-5_37 · Cited by 3
Self-citationDoes the Danger from Asbestos in Buildings Warrant the Cost of Taking it Out
Dewees, D. N. (1987) · American Scientist · Cited by 1
Research works printed but not linked: 34
- Bousbaine, A. (1986). Personal communcation. Bundesgesundheitsamt (1981). Gesundheitliche Risiken uon Ashest. Eine Stellungnahme des Bundesgesund- heitsumtes. ( K . Aurland and W. S. Kierslu, eds.). Dietrich Reimer Verlag, Berlin, p. 51. Burdett, G. J. (1986). In Asbestos Fibres Measurements in Building Atmospheres. Proceedings (E. J. Chatfield, ed.). Ontario Research Foundation, Mis- sissauga, ON, pp. 87-110.
- Bundesgesundheitsamt ( 1981 ).Gesundheitliche Risiken von Asbest. Eine Stellungnahme des Bundesgesundheitsamtes.( K. Aurland and W. S. Kierski , eds.). Dietrich Reimer Verlag , Berlin , p. 51 .
- Burdett , G. J. ( 1986 ). InAsbestos Fibres Measurements in Building Atmospheres.Proceedings ( E. J. Chatfield , ed.). Ontario Research Foundation , Mississauga , ON , pp. 87 – 110 .
- Chase, G. R. (1979). In Dusts and Disease. Occupational and Enuironmental Exposures to selected Fihrous and Particulate Dusts. (R. Lemren and J. M. Dement, eds.). Pathotox Publications, Park Forest South, IL, pp. 181-183.
- Chatfield, E. J. (1985). In Fifth International Colloquium on Dust Measuring Technique and Strategy. ( F . Baunach, ed.). Asbestos International Association, London, pp. 269-296.
- Chatfield, E. J. (1986). In Asbestos Fibre Measurements in Building Atmospheres. Proceedings. (E. J. Chatfield, cd.). Ontario Research Foundation, Mississauga, ON, pp. 87-110.
- Cherrie, J. W., Dodgson, H. J., Groat, S., and Carson, M. (1987). TM/87/01. Institute of Occupational Medicine, Edinburg, p. 48. Churg, A., and Warnock, M. L. (1979). Am. Reu. Respir. Dis. 120:781-786.
- Dewees, D. N. (1987). Am. Sci. 75:285-288.
- Iselin, F., and Madelaine, P. (1984). Chantiers/Suisse 15:815-818.
- Kaufer, E., Carton, B., Vigneron, J. C., and Collignon, P. (1981). Enuiron-Mer 79:l-43.
- Krantz S., 1987, Newslett. Nord. Board. Occup. Saf. Health Sweden, 1
- Lanting , R. W. ( 1982 ). InProceedings of the World Symposium on Asbestos, Montreal, Canada, p. 295 – 305 .
- Le Bouffant L., 1985, Cah. Notes. Doc., 118, 83
- Lohrer W., 1983, Staub Reinhalt. Luft, 43, 434
- Lohrer W., 1986, Staub Reinhalt. Luft, 46, 519
- Marfels H., 1984, Staub Reinhalt. Luft, 44, 512
- 10.2307/3430132 · DOI
- National Research Countil. ( 1984 ).Asbestiform Fibers. Non-occupational Health Risks.National Academy Press, Washington, DC, p. 334 .
- Nicholson , W. J. ( 1983 ). InVDI Berichte 475( D. Reinisch , W. H. Sachneider , and K. F. Birkner , eds.). VDI Verlag , Düsseldorf , pp. 161 – 177 .
- NIOSH ( 1985 ). InManual of Analytical Methods.3rd ed. ( P. Eller , ed.). US-DHEW National Institute of Occupational Safety and Health , Cincinnati , OH , p. 9 .
- Ontario Research Foundation. ( 1986 ).Asbestos Fiber Measurements in Building Atmospheres.Proceedings. ( E. J. Chatfield , ed.). ORF , Mississauga , ON , Canada , p. 298 .
- Pinchin , D. J. ( 1983 ).Asbestos in Buildings. Royal Commission on Asbestos Study Series, no. 8 in the report of the Royal Commission on Matters of Health and Safety Arising from the Use of Asbestos in Ontario. ( J. S. Dupr é, J. F. Mustard , and R. J. Uffen , eds.). Queens' Printer for Ontario , Toronto , ON , Canada , p. 573 .
- Pott F., 1978, Staub Reinhalt. Luft, 38, 486
- Rendall , R. E. G. , and Skine , M. I. ( 1980 ). InBiological Effects of Mineral Fibres.Vol. 2 . ( J. C. Wagner , ed.). WHO IARC Scientific Publication No. 30 : 837 – 844 .
- Robock K., 1984, Environmental Health Criteria No., 53
- Rood , A. P. , and Jaffreey , S. A. M. T. ( 1986 ). InAsbestos Fibre Measurements in Building Atmospheres.Proceedings. ORF , Mississauga , ON , Canada , pp. 159 – 167 .
- Royal Commission on Matters of Health and Safety Arising from the Use of Asbestos in Ontario. ( 1984 ). ( J. P. Dupré , J. F. Mustard , and R. J. H. Uften , eds.). Queens' Printer for Ontario , Toronto , ON , Canada , p. 920 .
- Sawyer , R. N. ( 1979 ). InDusts and Disease. Occupational and Environmental Exposures to Selected Fibrous and Particulate Dusts.( R. Lemen , and J. M. Dement , eds.). Pathotox Publications , Park Forest South , IL , pp. 175 – 179 .
- Schneiderman , M. S. , Nisbet , I. C. T. , and Brett , S. M. ( 1981 ). InBGA Berichte4/1981Gesundheitlicht Risiken von Asbest.( K. Amond , and W. S. Kierski , eds.). Dietrich Reimei Verlag , Berlin , pp. 3/1 - 3/28 .
- Sébastien P., 1976, Rev. Fr. Mal. Respir., 4, 51
- Sébastien , P. ( 1980 ). InReport of the Royal Commission on Matters of Health and Safety Arising from the Use of Asbestos in Ontario.( J. S. Dupr é, J. F. Mustard , and R. J. Uffen , eds.). Queens' Printer for Ontario , Toronto , ON , Canada , p. 573 .
- Sengbusch, G. von, and Hannibal-Friedrich, 0 . (1979). Staub Reinhalt. Luft 39:457-456.
- Spumy, K. (1984). Sruub Reinhalt. Luft 44:456-458.
- Verein Deutsche Ingenieure. (1985). Richtlinie 3492. Messen anorganischer, guserfimiger Partikeln in der Aussenluft: Rasterelektiontronmikroskopisches Ver- fahren. VDI Verlag, Diisseldorf.
Cited by
Boulanger, G., Andujar, P., Pairon, J.-C., Billon-Galland, M.-A., Dion, C., Dumortier, P., Brochard, P., Sobaszek, A., Bartsch, P., Paris, C., et al. (2014) · Environmental Health · doi:10.1186/1476-069x-13-59 · Cited by 176
“These results are consistent with published exposure data in indoor air obtained by TEM, indicating a high proportion of SAF; 90 to 100% in most studies [5-9].”
ResultAirborne Asbestos Exposures from Warm Air Heating Systems in Schools
Burdett, G. J., Dewberry, K., & Staff, J. (2015) · Annals of Occupational Hygiene · doi:10.1093/annhyg/mev062 · Cited by 10
“…be minimal, even on friable sprayed surfaces in return-air plenums (Nicholson et al., 1975; Sebastien et al., 1980; Burdett and Jaffrey, 1986), at ventilation outlets directed across friable sprayed ACM (Guillemin et al., 1989) and in specific experiments (Burdett, 1986; Keyes and Chesson, 1990)’.”
Background
Metadata
- Authors
- Guillemin, M. P., Madelaine, P., Litzistorf, G., Buffat, P., & Iselin, F.
- Venue
- Aerosol Science and Technology
- Publisher
- Informa UK Limited
- Published
- 1989-01
- Volume
- 11
- Issue
- 3
- Pages
- 221-243
- ISSN
- 0278-6826
- 1521-7388
- Semantic Scholar
- 8892447d8cb2acdcfa37d80dc12c3801cae94796
- Cited by
- 7
- References
- 27
- Language
- en
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.