Based on careful investigations carried out in 12 different buildings with and without friable asbestos containing insulation materials, different ways of exposure assessment are compared. Methods used are visual inspection algorithm, phase-contrast microscopy (PCM), direct reading instruments (FAM, fibrous aerosol monitor), scanning electron microscopy (SEM), and transmission electron microscopy (TEM). This last method was considered as a reference, because the complete size distribution of every type of mineral fiber can be assessed. The advantages and limitations of each method are discussed in the light of the results obtained. Among many others a few relevant findings may be cited: 1) In buildings where no known source of asbestos fibers exists high levels of fibers from unsuspected sources can be found. 2) The resuspension of settled fibers is one of the main sources of exposure and is related to the presence or activities of people in the concerned area. 3) The common belief that a ventilation system in contact with friable asbestos containing material is a major source of indoor pollution was not confirmed here. 4) In some situations all the chrysotile fibers longer than 5 μm were too thin to be seen either by PCM or SEM. 5) The size distribution varies according to the fiber type and the situation. The risk assessment based on a limited number of epidemiologic studies is strongly related to the method by which asbestos exposure is measured and to the relationship between the “old” methods used in the occupational environment and those presently used in nonoccupational situations.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1080/02786828908959315

Cites

27 of 27 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Research works printed but not linked: 34

  1. Bousbaine, A. (1986). Personal communcation. Bundesgesundheitsamt (1981). Gesundheitliche Risiken uon Ashest. Eine Stellungnahme des Bundesgesund- heitsumtes. ( K . Aurland and W. S. Kierslu, eds.). Dietrich Reimer Verlag, Berlin, p. 51. Burdett, G. J. (1986). In Asbestos Fibres Measurements in Building Atmospheres. Proceedings (E. J. Chatfield, ed.). Ontario Research Foundation, Mis- sissauga, ON, pp. 87-110.
  2. Bundesgesundheitsamt ( 1981 ).Gesundheitliche Risiken von Asbest. Eine Stellungnahme des Bundesgesundheitsamtes.( K. Aurland and W. S. Kierski , eds.). Dietrich Reimer Verlag , Berlin , p. 51 .
  3. Burdett , G. J. ( 1986 ). InAsbestos Fibres Measurements in Building Atmospheres.Proceedings ( E. J. Chatfield , ed.). Ontario Research Foundation , Mississauga , ON , pp. 87 – 110 .
  4. Chase, G. R. (1979). In Dusts and Disease. Occupational and Enuironmental Exposures to selected Fihrous and Particulate Dusts. (R. Lemren and J. M. Dement, eds.). Pathotox Publications, Park Forest South, IL, pp. 181-183.
  5. Chatfield, E. J. (1985). In Fifth International Colloquium on Dust Measuring Technique and Strategy. ( F . Baunach, ed.). Asbestos International Association, London, pp. 269-296.
  6. Chatfield, E. J. (1986). In Asbestos Fibre Measurements in Building Atmospheres. Proceedings. (E. J. Chatfield, cd.). Ontario Research Foundation, Mississauga, ON, pp. 87-110.
  7. Cherrie, J. W., Dodgson, H. J., Groat, S., and Carson, M. (1987). TM/87/01. Institute of Occupational Medicine, Edinburg, p. 48. Churg, A., and Warnock, M. L. (1979). Am. Reu. Respir. Dis. 120:781-786.
  8. Dewees, D. N. (1987). Am. Sci. 75:285-288.
  9. Iselin, F., and Madelaine, P. (1984). Chantiers/Suisse 15:815-818.
  10. Kaufer, E., Carton, B., Vigneron, J. C., and Collignon, P. (1981). Enuiron-Mer 79:l-43.
  11. Krantz S., 1987, Newslett. Nord. Board. Occup. Saf. Health Sweden, 1
  12. Lanting , R. W. ( 1982 ). InProceedings of the World Symposium on Asbestos, Montreal, Canada, p. 295 – 305 .
  13. Le Bouffant L., 1985, Cah. Notes. Doc., 118, 83
  14. Lohrer W., 1983, Staub Reinhalt. Luft, 43, 434
  15. Lohrer W., 1986, Staub Reinhalt. Luft, 46, 519
  16. Marfels H., 1984, Staub Reinhalt. Luft, 44, 512
  17. 10.2307/3430132 · DOI
  18. National Research Countil. ( 1984 ).Asbestiform Fibers. Non-occupational Health Risks.National Academy Press, Washington, DC, p. 334 .
  19. Nicholson , W. J. ( 1983 ). InVDI Berichte 475( D. Reinisch , W. H. Sachneider , and K. F. Birkner , eds.). VDI Verlag , Düsseldorf , pp. 161 – 177 .
  20. NIOSH ( 1985 ). InManual of Analytical Methods.3rd ed. ( P. Eller , ed.). US-DHEW National Institute of Occupational Safety and Health , Cincinnati , OH , p. 9 .
  21. Ontario Research Foundation. ( 1986 ).Asbestos Fiber Measurements in Building Atmospheres.Proceedings. ( E. J. Chatfield , ed.). ORF , Mississauga , ON , Canada , p. 298 .
  22. Pinchin , D. J. ( 1983 ).Asbestos in Buildings. Royal Commission on Asbestos Study Series, no. 8 in the report of the Royal Commission on Matters of Health and Safety Arising from the Use of Asbestos in Ontario. ( J. S. Dupr é, J. F. Mustard , and R. J. Uffen , eds.). Queens' Printer for Ontario , Toronto , ON , Canada , p. 573 .
  23. Pott F., 1978, Staub Reinhalt. Luft, 38, 486
  24. Rendall , R. E. G. , and Skine , M. I. ( 1980 ). InBiological Effects of Mineral Fibres.Vol. 2 . ( J. C. Wagner , ed.). WHO IARC Scientific Publication No. 30 : 837 – 844 .
  25. Robock K., 1984, Environmental Health Criteria No., 53
  26. Rood , A. P. , and Jaffreey , S. A. M. T. ( 1986 ). InAsbestos Fibre Measurements in Building Atmospheres.Proceedings. ORF , Mississauga , ON , Canada , pp. 159 – 167 .
  27. Royal Commission on Matters of Health and Safety Arising from the Use of Asbestos in Ontario. ( 1984 ). ( J. P. Dupré , J. F. Mustard , and R. J. H. Uften , eds.). Queens' Printer for Ontario , Toronto , ON , Canada , p. 920 .
  28. Sawyer , R. N. ( 1979 ). InDusts and Disease. Occupational and Environmental Exposures to Selected Fibrous and Particulate Dusts.( R. Lemen , and J. M. Dement , eds.). Pathotox Publications , Park Forest South , IL , pp. 175 – 179 .
  29. Schneiderman , M. S. , Nisbet , I. C. T. , and Brett , S. M. ( 1981 ). InBGA Berichte4/1981Gesundheitlicht Risiken von Asbest.( K. Amond , and W. S. Kierski , eds.). Dietrich Reimei Verlag , Berlin , pp. 3/1 - 3/28 .
  30. Sébastien P., 1976, Rev. Fr. Mal. Respir., 4, 51
  31. Sébastien , P. ( 1980 ). InReport of the Royal Commission on Matters of Health and Safety Arising from the Use of Asbestos in Ontario.( J. S. Dupr é, J. F. Mustard , and R. J. Uffen , eds.). Queens' Printer for Ontario , Toronto , ON , Canada , p. 573 .
  32. Sengbusch, G. von, and Hannibal-Friedrich, 0 . (1979). Staub Reinhalt. Luft 39:457-456.
  33. Spumy, K. (1984). Sruub Reinhalt. Luft 44:456-458.
  34. Verein Deutsche Ingenieure. (1985). Richtlinie 3492. Messen anorganischer, guserfimiger Partikeln in der Aussenluft: Rasterelektiontronmikroskopisches Ver- fahren. VDI Verlag, Diisseldorf.

Cited by

See all 7

Metadata

Authors
Guillemin, M. P., Madelaine, P., Litzistorf, G., Buffat, P., & Iselin, F.
Venue
Aerosol Science and Technology
Published
1989-01
Volume
11
Issue
3
Pages
221-243
ISSN
  • 0278-6826
  • 1521-7388
Cited by
7
References
27
Language
en

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.