Fluorescence Particle Counter for Detecting Airborne Bacteria and Other Biological Particles
Open accessThe DOI matches its Crossref record.
Abstract
We have constructed a laser-based particle counter that detects the fluorescence, as well as the elastic scattering, from individual airborne particles as they traverse a laser beam. This fluorescence particle counter (FPC) can detect fluorescence from μm-sized Bacillus subtilis spore agglomerates when illuminated with intense light at 488 nm from an argon ion laser, either ∼ 0.7 kW cm−2 extracavity or ∼ 50 kW cm−2 intracavity. We suspect that flavins in the spores are the molecules primarily responsible for the fluorescence, because the peak fluorescence emission of the biological materials at this excitation wavelength is in the range 530–550 nm, which is characteristic of flavins. Fluorescence from kaolin, hematite, and polystyrene particles was not detectable; the lack of fluorescence indicates that the FPC may be able to differentiate between biological and nonbiological aerosols. The FPC samples aerosol-laden air at a rate of ∼ 1 mL s−1, and is capable of measuring aerosol concentrations up to several thousand per milliliter. The FPC may be helpful in detecting and characterizing airborne bacteria and other airborne particles of biological origin.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Bioaerosols in the Earth system: Climate, health, and ecosystem interactions
Fröhlich-Nowoisky, J., Kampf, C. J., Weber, B., Huffman, J. A., Pöhlker, C., Andreae, M. O., Lang-Yona, N., Burrows, S. M., Gunthe, S. S., Elbert, W., et al. (2016) · Atmospheric Research · doi:10.1016/j.atmosres.2016.07.018 · Cited by 1,007
Autofluorescence of atmospheric bioaerosols – fluorescent biomolecules and potential interferences
Pöhlker, C., Huffman, J. A., & Pöschl, U. (2012) · Atmospheric Measurement Techniques · doi:10.5194/amt-5-37-2012 · Cited by 394
“Within the last two decades, especially, the detection of bioaerosols used as biological warfare agents (BWA) has also become important, both on the battlefield and with respect to domestic terrorism (e.g. Hill et al., 1995; Pinnick et al., 1995; Primmerman, 2000; Ho, 2002; Lim et al., 2005; Manninen et al., 2008).”
BackgroundMethodReal-time sensing of bioaerosols: Review and current perspectives
Huffman, J. A., Perring, A. E., Savage, N. J., Clot, B., Crouzy, B., Tummon, F., Shoshanim, O., Damit, B., Schneider, J., Sivaprakasam, V., et al. (2020) · Aerosol Science and Technology · doi:10.1080/02786826.2019.1664724 · Cited by 299
Self-citationHairston, P. P., Ho, J., & Quant, F. R. (1997) · Journal of Aerosol Science · doi:10.1016/s0021-8502(96)00448-x · Cited by 231
Single particle multichannel bio-aerosol fluorescence sensor
Kaye, P. H., Stanley, W. R., Hirst, E., Foot, E. V., Baxter, K. L., & Barrington, S. J. (2005) · Optics Express · doi:10.1364/opex.13.003583 · Cited by 213
Metadata
- Authors
- Pinnick, R. G., Hill, S. C., Nachman, P., Pendleton, J. D., Fernandez, G. L., Mayo, M. W., & Bruno, J. G.
- Venue
- Aerosol Science and Technology
- Publisher
- Informa UK Limited
- Published
- 1995-01
- Volume
- 23
- Issue
- 4
- Pages
- 653-664
- ISSN
- 0278-6826 (ISSN-L)
- 1521-7388
- OpenAlex
- W1977378656
- Cited by
- 111
- References
- 0
- FWCI
- 3.52
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Fluorescence Particle Counter for Detecting Airborne Bacteria and Other Biological Particles. https://app.cochat.ai/papers/10.1080/02786829508965345
- The paper
- Pinnick, R. G., Hill, S. C., Nachman, P., Pendleton, J. D., Fernandez, G. L., Mayo, M. W., & Bruno, J. G. (1995). Fluorescence Particle Counter for Detecting Airborne Bacteria and Other Biological Particles. Aerosol Science and Technology. https://doi.org/10.1080/02786829508965345
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.