Size and Fluorescence Measurements for Field Detection of Biological Aerosols
Open accessThe DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
This paper describes an instrument developed to monitor the biological fraction of an aerosol. The instrument simultaneously sizes individual particles in a flowing air stream and measures their total fluorescence following excitation at 266 nm. Laboratory data show that these two parameters enable discrimination between individuals of certain bacterial species. Field measurements are presented in which bacterial samples were aerosolized and subsequently detected 800 m downwind.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Hairston, P. P., Ho, J., & Quant, F. R. (1997) · Journal of Aerosol Science · doi:10.1016/s0021-8502(96)00448-x · Cited by 231
Cited by
Primary biological aerosol particles in the atmosphere: a review
Després, V. R., Huffman, J. A., Burrows, S. M., Hoose, C., Safatov, A. S., Buryak, G., Fröhlich-Nowoisky, J., Elbert, W., Andreae, M. O., Pöschl, U., et al. (2012) · Tellus B: Chemical and Physical Meteorology · doi:10.3402/tellusb.v64i0.15598 · Cited by 1,500
“However, these technical and scientific developments have been significant contributions to the scientific community (e.g. Hill et al., 1995; Cheng et al., 1999; Reyes et al., 1999; Seaver et al., 1999; Kopczynski et al., 2005; Cabredo et al., 2007; Campbell et al., 2007; Manninen et al., 2008; Pan et al., 2009; Sivap…”
BackgroundAutofluorescence of atmospheric bioaerosols – fluorescent biomolecules and potential interferences
Pöhlker, C., Huffman, J. A., & Pöschl, U. (2012) · Atmospheric Measurement Techniques · doi:10.5194/amt-5-37-2012 · Cited by 394
“BWA sensors are designed to detect suspicious agents reliably, even in low concentrations, with a low falsepositive rate and with short response.”
BackgroundInfluentialReal-time sensing of bioaerosols: Review and current perspectives
Huffman, J. A., Perring, A. E., Savage, N. J., Clot, B., Crouzy, B., Tummon, F., Shoshanim, O., Damit, B., Schneider, J., Sivaprakasam, V., et al. (2020) · Aerosol Science and Technology · doi:10.1080/02786826.2019.1664724 · Cited by 299
Prospects for point-of-care pathogen diagnostics using surface-enhanced Raman scattering (SERS)
Granger, J. H., Schlotter, N. E., Crawford, A. C., & Porter, M. D. (2016) · Chemical Society Reviews · doi:10.1039/c5cs00828j · Cited by 269
FAST CARS: Engineering a laser spectroscopic technique for rapid identification of bacterial spores
Scully, M. O., Kattawar, G. W., Lucht, R. P., Opatrný, T., Pilloff, H., Rebane, A., Sokolov, A. V., & Zubairy, M. S. (2002) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.172290899 · Cited by 222
Single particle multichannel bio-aerosol fluorescence sensor
Kaye, P. H., Stanley, W. R., Hirst, E., Foot, E. V., Baxter, K. L., & Barrington, S. J. (2005) · Optics Express · doi:10.1364/opex.13.003583 · Cited by 213
Huffman, J. A., Treutlein, B., & Pöschl, U. (2010) · Atmospheric Chemistry and Physics · doi:10.5194/acp-10-3215-2010 · Cited by 212
“Within the last decades and motivated by need to detect bioaerosols as possible Bio-Warfare Agents (BWA), the application of ultraviolet Laser-Induced Fluorescence (LIF) to online aerosol analysis has enabled the detection of PBAPs in real-time, with time resolution of minutes or less (Hill et al., 1995; Pinnick et al…”
BackgroundHuffman, J. A., Sinha, B., Garland, R. M., Snee-Pollmann, A., Gunthe, S. S., Artaxo, P., Martin, S. T., Andreae, M. O., & Pöschl, U. (2012) · Atmospheric Chemistry and Physics · doi:10.5194/acp-12-11997-2012 · Cited by 207
“…science community by enabling real-time analyses with much higher time and particle size resolution than had been previously attainable (e.g., Pinnick et al., 1995; Hairston et al., 1997; Seaver et al., 1999; Sivaprakasam et al., 2004; Kaye et al., 2005; Pan et al., 2011; Healy et al., 2012).”
MethodReal-time measurement of fluorescence spectra from single airborne biological particles
Hill, S. C., Pinnick, R. G., Niles, S., Pan, Y.-L., Holler, S., Chang, R. K., Bottiger, J., Chen, B. T., Orr, C.-S., & Feather, G. (1999) · Field Analytical Chemistry & Technology · doi:10.1002/(sici)1520-6521(1999)3:4/5<221::aid-fact2>3.0.co;2-7 · Cited by 205
Pan, Y.-L., Holler, S., Chang, R. K., Hill, S. C., Pinnick, R. G., Niles, S., & Bottiger, J. R. (1999) · Optics Letters · doi:10.1364/ol.24.000116 · Cited by 111
Metadata
- Authors
- Seaver, M., Eversole, J. D., Hardgrove, J. J., Cary, W. K., & Roselle, D. C.
- Venue
- Aerosol Science and Technology
- Publisher
- Informa UK Limited
- Published
- 1999-02
- Volume
- 30
- Issue
- 2
- Pages
- 174-185
- ISSN
- 0278-6826 (ISSN-L)
- 1521-7388
- OpenAlex
- W1977517847
- Cited by
- 92
- References
- 1
- FWCI
- 5.53
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.