Usefulness of computed tomography linear measurements in diagnosing alzheimer's disease
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Background: Medial temporal lobe atrophy (MTA) is an early sign of Alzheimer's disease (AD). The current method of choice for measuring MTA is volumetric measurement based on 3D magnetic resonance imaging (MRI), but this complicated method has not been implemented clinically. Purpose: To investigate whether simple computed tomography (CT) linear measurements of the brain could be of value in AD workup. Material and Methods: Fifty-nine healthy control subjects and 248 AD subjects were recruited. They were evaluated using a comprehensive clinical workup. A series of linear CT measurements were obtained from brain CT. Results: In discriminant analysis, the temporal horn ratio and the suprasellar cistern ratio were the atrophy factors that contributed most significantly to the diagnoses. Combined with other clinical factors (apolipoprotein E4 genotype), a correct AD classification of 90.2% was achieved. Conclusion: CT linear measurements could be of value in the workup of AD patients, considering the inexpensiveness and availability of CT as well as the simplicity of linear measurements.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Quantitative NMR measurements of hippocampal atrophy in Alzheimer's disease
Seab, J. P., Jagust, W. J., Wong, S. T. S., Roos, M. S., Reed, B. R., & Budinger, T. F. (1988) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910080210 · Cited by 364
Cited by
Cerebrospinal fluid and plasma biomarkers in Alzheimer disease
Blennow, K., Hampel, H., Weiner, M., & Zetterberg, H. (2010) · Nature Reviews Neurology · doi:10.1038/nrneurol.2010.4 · Cited by 1,863
Schweizer, T. A., Ware, J., Fischer, C. E., Craik, F. I. M., & Bialystok, E. (2012) · Cortex · doi:10.1016/j.cortex.2011.04.009 · Cited by 363
“Linearmeasurementswere taken as described by Zhang et al. (2008, 2009) (see Fig.”
BackgroundMethodInfluentialClassification of CT brain images based on deep learning networks
Gao, X. W., Hui, R., & Tian, Z. (2017) · Computer Methods and Programs in Biomedicine · doi:10.1016/j.cmpb.2016.10.007 · Cited by 351
Fluid Biomarkers in Alzheimer Disease
Blennow, K., Zetterberg, H., & Fagan, A. M. (2012) · Cold Spring Harbor Perspectives in Medicine · doi:10.1101/cshperspect.a006221 · Cited by 208
“Positive CSF biomarkers combined with either CTor MRI measurements of medial temporal lobe atrophy have been found to increase the accuracy of an AD diagnosis (Schoonenboom et al. 2008; Zhang et al. 2008; Brys et al. 2009b).”
Background
Metadata
- Authors
- Zhang, Y., Londos, E., Minthon, L., Wattmo, C., Liu, H., Aspelin, P., & Wahlund, L. O.
- Venue
- Acta Radiologica
- Publisher
- SAGE Publications
- Published
- 2008-02
- Volume
- 49
- Issue
- 1
- Pages
- 91-97
- ISSN
- 0284-1851 (ISSN-L)
- 1600-0455
- OpenAlex
- W2115656718
- Cited by
- 68
- References
- 1
- FWCI
- 2.72
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Usefulness of computed tomography linear measurements in diagnosing alzheimer's disease. https://app.cochat.ai/papers/10.1080/02841850701753706
- The paper
- Zhang, Y., Londos, E., Minthon, L., Wattmo, C., Liu, H., Aspelin, P., & Wahlund, L. O. (2008). Usefulness of computed tomography linear measurements in diagnosing alzheimer's disease. Acta Radiologica. https://doi.org/10.1080/02841850701753706
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.