The DOI matches its Crossref record.
Adjoint-based constrained topology optimization for viscous flows, including heat transfer
Abstract
In fluid mechanics, topology optimization is used for designing flow passages, connecting predefined inlets and outlets, with optimal performance based on selected criteria. In this article, the continuous adjoint approach to topology optimization in incompressible ducted flows with heat transfer is presented. A variable porosity field, to be determined during the optimization, is the means to define the optimal topology. The objective functions take into account viscous losses and the amount of heat transfer. Turbulent flows are handled using the Spalart–Allmaras model and the proposed adjoint is exact, i.e. the adjoint to the turbulence model equation is formulated and solved, too. This is an important novelty in this article which extends the porosity-based method to account for heat transfer flow problems in turbulent flows. In problems such as the design of manifolds, constraints on the outlet flow direction, rates and mean outlet temperatures are imposed.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
A review about the engineering design of optimal heat transfer systems using topology optimization
Dbouk, T. (2017) · Applied Thermal Engineering · doi:10.1016/j.applthermaleng.2016.10.134 · Cited by 469
Topology optimization of heat exchangers: A review
Fawaz, A., Hua, Y., Le Corre, S., Fan, Y., & Luo, L. (2022) · Energy · doi:10.1016/j.energy.2022.124053 · Cited by 273
Topology optimization of turbulent flows
Dilgen, C. B., Dilgen, S. B., Fuhrman, D. R., Sigmund, O., & Lazarov, B. S. (2018) · Computer Methods in Applied Mechanics and Engineering · doi:10.1016/j.cma.2017.11.029 · Cited by 270
Design and evaluation of an additively manufactured aircraft heat exchanger
Saltzman, D., Bichnevicius, M., Lynch, S., Simpson, T. W., Reutzel, E. W., Dickman, C., & Martukanitz, R. (2018) · Applied Thermal Engineering · doi:10.1016/j.applthermaleng.2018.04.032 · Cited by 169
Topology optimisation of biphasic adsorbent beds for gas storage
Amigo, R. C. R., Prado, D. S., Paiva, J. L., Hewson, R. W., & Silva, E. C. N. (2018) · Structural and Multidisciplinary Optimization · doi:10.1007/s00158-018-2117-x · Cited by 13
Metadata
- Authors
- Kontoleontos, E. A., Papoutsis-Kiachagias, E. M., Zymaris, A. S., Papadimitriou, D. I., & Giannakoglou, K. C.
- Venue
- Engineering Optimization
- Publisher
- Informa UK Limited
- Published
- 2013-08
- Volume
- 45
- Issue
- 8
- Pages
- 941-961
- ISSN
- 0305-215X (ISSN-L)
- 1029-0273
- OpenAlex
- W1987665324
- Cited by
- 162
- References
- 0
- FWCI
- 10.97
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Adjoint-based constrained topology optimization for viscous flows, including heat transfer. https://app.cochat.ai/papers/10.1080/0305215x.2012.717074
- The paper
- Kontoleontos, E. A., Papoutsis-Kiachagias, E. M., Zymaris, A. S., Papadimitriou, D. I., & Giannakoglou, K. C. (2013). Adjoint-based constrained topology optimization for viscous flows, including heat transfer. Engineering Optimization. https://doi.org/10.1080/0305215x.2012.717074
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.