Ionic liquids versus ionic liquid-based surfactants in dispersive liquid–liquid microextraction for determining copper in water by flame atomic absorption spectrometry
The DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.
Abstract
Juan F. Ayala-Cabreraa, María J. Trujillo-Rodrígueza, Verónica Pinoa*, Óscar M. Hernández-Torresa, Ana M. Afonsoa & Juliette Sirieix-Plénetba Departamento de Química, Unidad Departamental de Química Analítica, Universidad de La Laguna (ULL), La Laguna (Tenerife), Spainb CNRS, Laboratoire PHENIX, Sorbonne Universités, UPMC Univ Paris 06, Paris, FranceCONTACT Verónica Pino veropino@ull.edu.esABSTRACTThis work compares the performance of dispersive liquid–liquid method (DLLME) as a prior step for determining copper by flame atomic absorption spectrometry (FAAS), when using the ionic liquid (IL) 1-butyl-3-methylimidazolium hexafluorophosphate (C4MIm-PF6) or the IL-based surfactant 1-hexadecyl-3-butylimidazolium bromide (C16C4Im-Br) as extractant solvents. For the water-insoluble C4MIm-PF6, the most conventional DLLME mode using acetonitrile as dispersive solvent was employed. For the water-soluble C16C4Im-Br, the in situ DLLME mode with lithium bis[(trifluoromethane)sulfonyl]imide (Li-NTf2) as metathesis reagent was employed. In both approaches, some effective parameters such as volumes of extractant and dispersive solvents, concentration of complexing agent, pH of sample solution, salting-out effect and final diluting solvent to ensure compatibility with FAAS, were properly optimised. The optimum conditions for the IL-DLLME method using C4MIm-PF6 were: 100 μL of neat C4MIm-PF6, 1 mL of acetonitrile, 10 mL of water, no control of pH for environmental waters, NaCl content of 23 g L−1, diethyl dithiocarbamate (DDTC) as complexing agent at 10 mg L−1 and final dilution of the micro-droplet with acetonitrile up to 70 µL. The optimum conditions for the in situ IL-DLLME method using C16C4Im-Br were: 0.8 mL of acetonitrile, 10 mL of water containing C16C4Im-Br at 25.2 mmol L−1, final dilution step of the micro-droplet with 200 µL of acetonitrile and remaining conditions as those of C4MIm-PF6. The analytical performance of both methods was similar, being slightly better for the IL-DLLME method using C4MIm-PF6, with limits of detection (LOD) of 3.3 µg L−1 (versus 5.1 µg L−1 when using C16C4Im-Br), precision values as intraday relative standard deviation (RSD in %) lower than 8.8% (being of 10% for the C16C4Im-Br method) and an enrichment factor of 54 (being 27 when using C16C4Im-Br). The DLLME-FAAS method with C4MIm-PF6 was used in the analysis of environmental waters with successful performance, with relative recoveries of 110% and 105%, and interday precision with RSD values of 21% and 7.4% for spiked levels of 60 and 160 µg L−1, respectively. The results obtained when analysing an urban wastewater sample coming from an inter-laboratory exercise was comparable to those obtained for other 93 laboratories. The method was also valid for the determination of Cu2+ in presence of foreign ions commonly found in natural waters.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Gałuszka, A., Migaszewski, Z., & Namieśnik, J. (2013) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2013.04.010 · Cited by 2,461
H. Davis, J. (2004) · Chemistry Letters · doi:10.1246/cl.2004.1072 · Cited by 1,053
The role of green extraction techniques in Green Analytical Chemistry
Armenta, S., Garrigues, S., & de la Guardia, M. (2015) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2014.12.011 · Cited by 329
Ionic liquids in dispersive liquid-liquid microextraction
Trujillo-Rodríguez, M. J., Rocío-Bautista, P., Pino, V., & Afonso, A. M. (2013) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2013.06.008 · Cited by 276
Self-citationRecent development and applications of dispersive liquid–liquid microextraction
Yan, H., & Wang, H. (2013) · Journal of Chromatography A · doi:10.1016/j.chroma.2013.04.053 · Cited by 256
Beyond dispersive liquid–liquid microextraction
Leong, M.-I., Fuh, M.-R., & Huang, S.-D. (2014) · Journal of Chromatography A · doi:10.1016/j.chroma.2014.02.021 · Cited by 241
Yao, C., & Anderson, J. L. (2009) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-009-3078-0 · Cited by 204
Stanisz, E., Werner, J., & Zgoła-Grześkowiak, A. (2014) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2014.06.008 · Cited by 116
Research works printed but not linked: 35
- 10.1016/j.watres.2014.08.013 · DOI · Paper page
- 10.1007/s00604-010-0402-5 · DOI
- 10.1016/0048-9697(75)90029-7 · DOI
- National Research Council,Dietary Reference Intakes for Vitamin A, Vitamin K, Arsenic, Boron, Chromium, Copper, Iodine, Iron, Manganese, Molybdenum, Nickel, Silicon, Vanadium and Zinc(National Academy Press, Washington, DC, 2001), p. 224.
- United States Environmental Protection Agency (US-EPA), 2014, National Primary Drinking Water Regulations, List of Contaminants and Their Maximum Contaminant Levels
- World Health Organization (WHO), 2004, Copper in Drinking-Water, Background Document for Development of WHO Guidelines for Drinking-Water Quality
- 10.1039/c3ay41112e · DOI
- 10.1002/jms.1216 · DOI · Paper page
- 10.1016/j.jenvman.2014.11.030 · DOI · Paper page
- 10.1016/j.aca.2008.02.034 · DOI
- 10.1016/j.saa.2011.05.095 · DOI
- 10.1016/j.talanta.2014.05.048 · DOI
- 10.1016/j.saa.2015.03.129 · DOI
- 10.1016/j.trac.2012.10.011 · DOI
- 10.1016/j.sab.2012.05.003 · DOI
- 10.1016/j.talanta.2010.10.052 · DOI
- 10.1126/science.1090313 · DOI · Paper page
- 10.1021/ac4035554 · DOI · Paper page
- 10.1080/01496395.2011.620589 · DOI · Paper page
- 10.1002/9781118854501.ch23 · DOI
- 10.1016/j.talanta.2012.07.073 · DOI
- 10.1016/j.talanta.2011.04.054 · DOI
- 10.1016/j.chroma.2011.12.097 · DOI
- 10.1016/j.desal.2010.08.032 · DOI
- 10.1016/j.molliq.2014.01.026 · DOI
- 10.1016/j.foodchem.2014.07.015 · DOI
- 10.1080/00032719.2014.999276 · DOI · Paper page
- 10.1007/s00604-014-1434-z · DOI
- 10.1007/s00604-011-0757-2 · DOI
- 10.1039/b615406a · DOI · Paper page
- 10.1016/j.fct.2010.03.005 · DOI
- 10.1016/j.aca.2008.12.017 · DOI · Paper page
- 10.1016/j.chroma.2013.05.009 · DOI
- 10.1016/j.talanta.2009.12.038 · DOI
- 10.1016/j.aca.2014.04.057 · DOI · Paper page
Cited by
Rykowska, I., Ziemblińska, J., & Nowak, I. (2018) · Journal of Molecular Liquids · doi:10.1016/j.molliq.2018.03.043 · Cited by 353
Surface-active ionic liquids: A review
Buettner, C. S., Cognigni, A., Schröder, C., & Bica-Schröder, K. (2022) · Journal of Molecular Liquids · doi:10.1016/j.molliq.2021.118160 · Cited by 268
Herce-Sesa, B., López-López, J. A., & Moreno, C. (2021) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2021.116398 · Cited by 86
State-of-the-art on the technique of dispersive liquid-liquid microextraction
Wang, Q., Chen, R., Shatner, W., Cao, Y., & Bai, Y. (2019) · Ultrasonics Sonochemistry · doi:10.1016/j.ultsonch.2018.08.010 · Cited by 86
Shishov, A., Volodina, N., Semenova, E., Navolotskaya, D., Ermakov, S., & Bulatov, A. (2022) · Food Chemistry · doi:10.1016/j.foodchem.2021.131456 · Cited by 60
Metadata
- Authors
- Ayala-Cabrera, J. F., Trujillo-Rodríguez, M. J., Pino, V., Hernández-Torres, Ó. M., Afonso, A. M., & Sirieix-Plénet, J.
- Venue
- International Journal of Environmental Analytical Chemistry
- Publisher
- Informa UK Limited
- Published
- 2015-12-29
- Volume
- 96
- Issue
- 2
- Pages
- 101-118
- ISSN
- 0306-7319 (ISSN-L)
- 1029-0397
- OpenAlex
- W2203434971
- Cited by
- 39
- References
- 8
- FWCI
- 3.50
- Type
- journal article
- Language
- en
- Open access
- closed
- Funders
- Fundación CajaCanarias (Project ref. SPDs–AGUA05)
- Spanish Ministry of Economy and Competitiveness (MINECO) (Project Ref. MAT2014–57465–R, Project ref. MAT2013-43101-R, Ramón y Cajal contract)
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.