A perspective on medical infrared imaging
The DOI matches its Crossref record; 24 of the 24 references it cites were found in a registry or an index.
Abstract
Since the early days of thermography in the 1950s, image processing techniques, sensitivity of thermal sensors and spatial resolution have progressed greatly, holding out fresh promise for infrared (IR) imaging techniques. Applications in civil, industrial and healthcare fields are thus reaching a high level of technical performance. The relationship between body temperature and disease was documented since 400 bc. In many diseases there are variations in blood flow, and these in turn affect the skin temperature. IR imaging offers a useful and non-invasive approach to the diagnosis and treatment (as therapeutic aids) of many disorders, in particular in the areas of rheumatology, dermatology, orthopaedics and circulatory abnormalities. This paper reviews many usages (and hence the limitations) of thermography in biomedical fields.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Analysis of Tissue and Arterial Blood Temperatures in the Resting Human Forearm
Pennes, H. H. (1948) · Journal of Applied Physiology · doi:10.1152/jappl.1948.1.2.93 · Cited by 4,646
Analysis of Tissue and Arterial Blood Temperatures in the Resting Human Forearm
Pennes, H. H. (1998) · Journal of Applied Physiology · doi:10.1152/jappl.1998.85.1.5 · Cited by 3,982
A reappraisal of the use of infrared thermal image analysis in medicine
Jones, B. F. (1998) · IEEE Transactions on Medical Imaging · doi:10.1109/42.746635 · Cited by 572
Recent developments in modeling heat transfer in blood perfused tissues
Arkin, H., Xu, L. X., & Holmes, K. R. (1994) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.284920 · Cited by 431
A mathematical model of the human thermal system
Wissler, E. H. (1964) · The Bulletin of Mathematical Biophysics · doi:10.1007/bf02476835 · Cited by 196
IEEE Engineering in Medicine and Biology Magazine
(1982) · IEEE Engineering in Medicine and Biology Magazine · doi:10.1109/emb-m.1982.5005794 · Cited by 192
Analysis of IR thermal imager for mass blind fever screening
Ng, E. Y. K., Kawb, G. J. L., & Chang, W. M. (2004) · Microvascular Research · doi:10.1016/j.mvr.2004.05.003 · Cited by 182
Self-citationSahiner, B., Petrick, N., Chan, H.-P., Hadjiiski, L. M., Paramagul, C., Helvie, M. A., & Gurcan, M. N. (2001) · IEEE Transactions on Medical Imaging · doi:10.1109/42.974922 · Cited by 174
Comparison of visible and infra-red imagery for face recognition
Wilder, J., Phillips, P. J., Jiang, C., & Wiener, S. (2002) · Proceedings of the Second International Conference on Automatic Face and Gesture Recognition · doi:10.1109/afgr.1996.557262 · Cited by 161
Collins, A. J., Ring, E. F. J., Cosh, J., & BACON, P. A. (1974) · Annals of the Rheumatic Diseases · doi:10.1136/ard.33.2.113 · Cited by 151
Cited by
Medical applications of infrared thermography: A review
Lahiri, B. B., Bagavathiappan, S., Jayakumar, T., & Philip, J. (2012) · Infrared Physics & Technology · doi:10.1016/j.infrared.2012.03.007 · Cited by 1,333
Classification of factors influencing the use of infrared thermography in humans: A review
Fernández-Cuevas, I., Bouzas Marins, J. C., Arnáiz Lastras, J., Gómez Carmona, P. M., Piñonosa Cano, S., García-Concepción, M. Á., & Sillero-Quintana, M. (2015) · Infrared Physics & Technology · doi:10.1016/j.infrared.2015.02.007 · Cited by 586
A review of thermography as promising non-invasive detection modality for breast tumor
Ng, E. Y.-K. (2009) · International Journal of Thermal Sciences · doi:10.1016/j.ijthermalsci.2008.06.015 · Cited by 448
Self-citationAn Overview of Recent Application of Medical Infrared Thermography in Sports Medicine in Austria
Hildebrandt, C., Raschner, C., & Ammer, K. (2010) · Sensors · doi:10.3390/s100504700 · Cited by 419
A Survey on Computer Vision for Assistive Medical Diagnosis From Faces
Thevenot, J., Lopez, M. B., & Hadid, A. (2018) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2017.2754861 · Cited by 168
Bitar, D., Goubar, A., & Desenclos, J. C. (2009) · Eurosurveillance · doi:10.2807/ese.14.06.19115-en · Cited by 150
“While ribavirin has been shown to be effective in early-stage arenavirus infections, particularly Lassa virus [ 2 ], in the absence of proven effectiveness for prophylaxis [3], oral ribavirin was not recommended for persons who might have been exposed to the case described here.”
BackgroundMethodInfluentialKosus, N., Kosus, A., Duran, M., Simavli, S., & Turhan, N. (2010) · Journal of the Turkish-German Gynecological Association · doi:10.5152/jtgga.2010.24 · Cited by 49
Mottling score and skin temperature in septic shock: Relation and impact on prognosis in ICU
Ferraris, A., Bouisse, C., Mottard, N., Thiollière, F., Anselin, S., Piriou, V., & Allaouchiche, B. (2018) · PLOS ONE · doi:10.1371/journal.pone.0202329 · Cited by 45
Weigert, M., Nitzsche, N., Kunert, F., Lösch, C., Baumgärtel, L., & Schulz, H. (2018) · International Journal of Kinesiology and Sports Science · doi:10.7575/aiac.ijkss.v.6n.1p.12 · Cited by 28
Metadata
- Authors
- Jiang, L. J., Ng, E. Y. K., Yeo, A. C. B., Wu, S., Pan, F., Yau, W. Y., Chen, J. H., & Yang, Y.
- Venue
- Journal of Medical Engineering & Technology
- Publisher
- Informa UK Limited
- Published
- 2005-01
- Volume
- 29
- Issue
- 6
- Pages
- 257-267
- ISSN
- 0309-1902 (ISSN-L)
- 1464-522X
- OpenAlex
- W1972868773
- Cited by
- 283
- References
- 24
- FWCI
- 4.05
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.