The DOI matches its Crossref record.
A reappraisal of the use of infrared thermal image analysis in medicine
Abstract
Infrared thermal imaging of the skin has been used for several decades to monitor the temperature distribution of human skin. Abnormalities such as malignancies, inflammation, and infection cause localized increases in temperature which show as hot spots or as asymmetrical patterns in an infrared thermogram. Even though it is nonspecific, infrared thermology is a powerful detector of problems that affect a patient's physiology. While the use of infrared imaging is increasing in many industrial and security applications, it has declined in medicine probably because of the continued reliance on first generation cameras. The transfer of military technology for medical use has prompted this reappraisal of infrared thermology in medicine. Digital infrared cameras have much improved spatial and thermal resolutions, and libraries of image processing routines are available to analyze images captured both statically and dynamically. If thermographs are captured under controlled conditions, they may be interpreted readily to diagnose certain conditions and to monitor the reaction of a patient's physiology to thermal and other stresses. Some of the major areas where infrared thermography is being used successfully are neurology, vascular disorders, rheumatic diseases, tissue viability, oncology (especially breast cancer), dermatological disorders, neonatal, ophthalmology, and surgery.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Terahertz Technology in Biology and Medicine
Siegel, P. H. (2004) · IEEE Transactions on Microwave Theory and Techniques · doi:10.1109/tmtt.2004.835916 · Cited by 1,378
Classification of factors influencing the use of infrared thermography in humans: A review
Fernández-Cuevas, I., Bouzas Marins, J. C., Arnáiz Lastras, J., Gómez Carmona, P. M., Piñonosa Cano, S., García-Concepción, M. Á., & Sillero-Quintana, M. (2015) · Infrared Physics & Technology · doi:10.1016/j.infrared.2015.02.007 · Cited by 586
Khandakar, A., Chowdhury, M. E. H., Reaz, M. B. I., Ali, S. H. M., Kiranyaz, S., Rahman, T., Chowdhury, M. H., Ayari, M. A., Alfkey, R., Bakar, A. A. A., et al. (2022) · Sensors · doi:10.3390/s22114249 · Cited by 74
The experiment study on infrared radiation spectrum of human body
Yu, W. L., Wang, Z., & Jin, L. (2012) · Proceedings of 2012 IEEE-EMBS International Conference on Biomedical and Health Informatics · doi:10.1109/bhi.2012.6211692 · Cited by 9
Metadata
- Authors
- Jones, B. F.
- Venue
- IEEE Transactions on Medical Imaging
- Published
- 1998
- Volume
- 17
- Issue
- 6
- Pages
- 1019-1027
- ISSN
- 0278-0062 (ISSN-L)
- OpenAlex
- W2133643452
- Cited by
- 572
- References
- 0
- FWCI
- 1.09
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A reappraisal of the use of infrared thermal image analysis in medicine. https://app.cochat.ai/papers/10.1109/42.746635
- The paper
- Jones, B. F. (1998). A reappraisal of the use of infrared thermal image analysis in medicine. IEEE Transactions on Medical Imaging. https://doi.org/10.1109/42.746635
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.