Socket Versus Bone-Anchored Trans-Femoral Prostheses: Hip Range of Motion and Sitting Comfort

Open access
Hagberg, K., Häggström, E., Uden, M., Brånemark, R. · 2005 · Prosthetics & Orthotics International
Cited by 187

The DOI matches its Crossref record; 19 of the 19 references it cites were found in a registry or an index.

Abstract

This is the first study to report on hip range of motion (ROM) among active prosthesis users, when wearing and not wearing a trans-femoral socket prosthesis and to compare with individuals rehabilitated with an osseointegrated bone-anchored prosthesis. In addition, discomfort when sitting with the prosthesis is reported in both groups. The study group all had a non-vascular amputation and were divided into those supplied with a socket prosthesis (S group) (n = 43, mean age 51 years, 74% men) or a bone-anchored prosthesis (OI group) (n = 20, mean age 46 years, 75% men). Active hip ROM was measured with a goniometer, and self-reported problems with discomfort when sitting were recorded. The hip motion decreased in all directions when wearing the socket prosthesis compared to without it (P < 0.001 for all directions), and 37% of the subjects had less than 90 degrees of hip flexion when wearing their prosthesis. Discomfort when sitting was reported among 44% (n = 19) in the S group and was more common among individuals with less than 90 degrees of hip flexion motion (P= 0.025). In the OI group, no restriction in hip motion was measured with the prosthesis, and no subject had less than 90 degrees of flexion and 5% (n = 1) reported discomfort when sitting. This study shows that a trans-femoral prosthetic socket significantly reduces the ROM of the hip and that discomfort when sitting is common among individuals wearing such prostheses. Further, the study confirms that individuals using a bone-anchored prosthesis have no restricted hip motion with the prosthesis and report very few problems with discomfort when sitting.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1080/03093640500238014

Cites

19 of 19 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Research works printed but not linked: 8

  1. Gottschalk, 1999, Transfemoral amputation: biomechanics and surgery, Clin Orthop, 361, 15, 10.1097/00003086-199904000-00003 · doi:10.1097/00003086-199904000-00003
  2. Hachisuka, 1999, Subjective evaluations and objective measurements of the ischial-ramal containment prosthesis, J Uoeh, 21, 107, 10.7888/juoeh.21.107 · doi:10.7888/juoeh.21.107
  3. Hoaglund, 1983, Evaluation of problems and needs of veteran lower-limb amputees in the San Francisco Bay area during the period 1977 – 1980, J Rehabil Res Dev, 20, 57
  4. Hollman, 2003, Passive hip rotation range of motion: effects of testing position and age in runners and non-runners, Physiotherapy Theory Pract, 19, 77, 10.1080/09593980307954 · DOI
  5. Jaegers, 1995, Changes in hip muscles after above-knee amputation, Clin Orthop, 319, 276
  6. Johnston, 1970, Hip motion measurements for selected activities of daily living, Clin Orthop, 72, 205
  7. Kapp, 2000, Transfemoral socket design and suspension options, Phys Med Rehabil Clin N Am, 11, 569, 10.1016/S1047-9651(18)30119-0 · doi:10.1016/s1047-9651(18)30119-0
  8. Schuch, 1999, Current transfemoral sockets, Clin Orthop, 361, 48, 10.1097/00003086-199904000-00007 · doi:10.1097/00003086-199904000-00007

Cited by

See all 187

Metadata

Authors
Hagberg, K., Häggström, E., Uden, M., & Brånemark, R.
Venue
Prosthetics & Orthotics International
Published
2005-08
Volume
29
Issue
2
Pages
153-163
ISSN
0309-3646 (ISSN-L)
OpenAlex
W2109075391
Cited by
187
References
19
FWCI
2.17
Type
journal article
Language
en
Open access
hybrid
Licence
journals.sagepub.com/page/policies/text-and-data-mining-license (tdm)

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.