A new procedure for testing equivalence in comparative bioavailability and other clinical trials
The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Abstract
The problem of testing for equivalence in clinical trials is restated here in terms of the proper clinical hypotheses and a simple classical frequentist significance test based on the central t distribution is derived. This method is then shown to be more powerful than the methods based on usual (shortest) and symmetric confidence intervals. We begin by considering a noncentral t statistic and then consider three approximations to it. A simulation is used to compare actual test sizes to the nominal values in crossover and completely randomized designs. A central t approximation was the best. The power calculation is then shown to be based on a central t distribution, and a method is developed for obtaining the sample size required to obtain a specified power. For the approximations, a simulation compares actual powers to those obtained for the t distribution and confirms that the theoretical results are close to the actual powers.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Dunnett, C. W., & Gent, M. (1977) · Biometrics · doi:10.2307/2529457 · Cited by 389
A pseudo-random number generator for the System/360
Lewis, P. A. W., Goodman, A. S., & Miller, J. M. (1969) · IBM Systems Journal · doi:10.1147/sj.82.0136 · Cited by 370
Symmetrical Confidence Intervals for Bioequivalence Trials
Westlake, W. J. (1976) · Biometrics · doi:10.2307/2529259 · Cited by 336
Use of Confidence Intervals in Analysis of Comparative Bioavailability Trials
Westlake, W. J. (1972) · Journal of Pharmaceutical Sciences · doi:10.1002/jps.2600610845 · Cited by 281
Bioequivalence Testing -- A Need to Rethink
Kirkwood, T. B. L., & Westlake, W. J. (1981) · Biometrics · doi:10.2307/2530573 · Cited by 221
Comparison of Different Methods for Decision-Making in Bioequivalence Assessment
Mandallaz, D., & Mau, J. (1981) · Biometrics · doi:10.2307/2530412 · Cited by 138
A Bayesian Approach to Bioequivalence for the 2 x 2 Changeover Design
Selwyn, M. R., Dempster, A. P., & Hall, N. (1981) · Biometrics · doi:10.2307/2530518 · Cited by 83
Cited by
Schuirmann, D. J. (1987) · Journal of Pharmacokinetics and Biopharmaceutics · doi:10.1007/bf01068419 · Cited by 2,696
Bioequivalence trials, intersection-union tests and equivalence confidence sets
Berger, R. L., & Hsu, J. C. (1996) · Statistical Science · doi:10.1214/ss/1032280304 · Cited by 620
Using significance tests to evaluate equivalence between two experimental groups.
Rogers, J. L., Howard, K. I., & Vessey, J. T. (1993) · Psychological Bulletin · doi:10.1037//0033-2909.113.3.553 · Cited by 566
Tryon, W. W. (2001) · Psychological Methods · doi:10.1037/1082-989x.6.4.371 · Cited by 391
Consideration of individual bioequivalence
Anderson, S., & Hauck, W. W. (1990) · Journal of Pharmacokinetics and Biopharmaceutics · doi:10.1007/bf01062202 · Cited by 248
“a = Pr[ Y or more bioequivalent subjects[ PE = PLB] (6)”
BackgroundSelf-citation
Metadata
- Authors
- Anderson, S., & Hauck, W. W.
- Venue
- Communications in Statistics - Theory and Methods
- Publisher
- Informa UK Limited
- Published
- 1983-01
- Volume
- 12
- Issue
- 23
- Pages
- 2663-2692
- ISSN
- 0361-0926 (ISSN-L)
- 1532-415X
- OpenAlex
- W2056430771
- Cited by
- 247
- References
- 7
- FWCI
- 1.46
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.