An Optical Profilometer for Surface Characterization of Magnetic Media
The DOI matches its Crossref record; 10 of the 10 references it cites were found in a registry or an index.
Abstract
Conventional surface-characterization techniques either are not sophisticated enough to provide complete surface-topographical data or cannot be employed because of the relatively low hardness of magnetic media. An optical profilometer has been developed which provides a noncontact method of obtaining surface characteristics from a magnetic medium. The system consists of a standard Leitz reflection microscope, a Mirau interferometer controlled by a piezoelectric transducer, a linear array of photodiode detectors, and a microcomputer. The combination yields a system that measures the optical-height variations of surfaces to a high degree of precision. This height variation is processed by a computer to provide surface-topographical statistical parameters, which are useful to predict tribological and magnetic performances of the head-media interface. Sample data of magnetic media (tape, floppy disk, and rigid disk) are presented.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Nonparametric Statistics for the Behavioral Sciences
Guitton, H., & Siegel, S. (1958) · Revue économique · doi:10.2307/3498751 · Cited by 35,245
The Kolmogorov-Smirnov Test for Goodness of Fit
Massey, F. J. (1951) · Journal of the American Statistical Association · doi:10.1080/01621459.1951.10500769 · Cited by 7,210
The Friction and Lubrication of Solids
Bowden, F. P., Tabor, D., & Palmer, F. (1951) · American Journal of Physics · doi:10.1119/1.1933017 · Cited by 5,890
Contact of nominally flat surfaces
Greenwood, J. A., & Williamson, J. B. P. (1966) · Proceedings of the Royal Society of London. Series A. Mathematical and Physical Sciences · doi:10.1098/rspa.1966.0242 · Cited by 5,692
NONPARAMETRIC STATISTICS FOR THE BEHAVIORAL SCIENCES
Sidney, S. (1957) · The Journal of Nervous and Mental Disease · doi:10.1097/00005053-195707000-00032 · Cited by 2,230
Table for Estimating the Goodness of Fit of Empirical Distributions
Smirnov, N. (1948) · The Annals of Mathematical Statistics · doi:10.1214/aoms/1177730256 · Cited by 1,723
Relation Between Surface Roughness and Specular Reflectance at Normal Incidence
Bennett, H. E., & Porteus, J. O. (1961) · Journal of the Optical Society of America · doi:10.1364/josa.51.000123 · Cited by 1,121
Random Process Model of Rough Surfaces
Nayak, P. R. (1971) · Journal of Lubrication Technology · doi:10.1115/1.3451608 · Cited by 904
Optical heterodyne profilometry
Sommargren, G. E. (1981) · Applied Optics · doi:10.1364/ao.20.000610 · Cited by 244
Discrete properties of random surfaces
Whitehouse, D. J., & Phillips, M. J. (1978) · Philosophical Transactions of the Royal Society of London Series A Mathematical and Physical Sciences · doi:10.1098/rsta.1978.0084 · Cited by 105
Cited by
Recent trends in surface metrology
Mathia, T. G., Pawlus, P., & Wieczorowski, M. (2011) · Wear · doi:10.1016/j.wear.2010.06.001 · Cited by 307
Xing, H. Z., Zhang, Q. B., Braithwaite, C. H., Pan, B., & Zhao, J. (2017) · Rock Mechanics and Rock Engineering · doi:10.1007/s00603-016-1164-0 · Cited by 174
“AND THEIR APPLICATIONS TO GEOMATERIALS Digital optical measurement techniques are varied in their scope and application, and include such diverse techniques as profilometry (Wyant et al. 1984), optical fibre sensors (Grattan and Meggitt 1995) and optical coherence tomography (Fercher et al. 2003).”
Method
Metadata
- Authors
- Wyant, J. C., Koliopoulos, C. L., Bhushan, B., & George, O. E.
- Venue
- A S L E Transactions
- Publisher
- Informa UK Limited
- Published
- 1984-01
- Volume
- 27
- Issue
- 2
- Pages
- 101-113
- ISSN
- 0569-8197 (ISSN-L)
- OpenAlex
- W2034278122
- Cited by
- 179
- References
- 10
- FWCI
- 8.39
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.