Optical heterodyne profilometry
The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Abstract
A noncontact optical technique for the measurement of surface profile is described, which has a height sensitivity of the order of 1 A. It is based on a common path heterodyne interferometer in which two orthogonally polarized beams of slightly different frequency are focused on the surface to be measured. One focal point acts as a reference as the other point circularly scans the surface. The phase of the beat frequency of the interfering return beams is directly proportional to the surface height. The results of a surface measurement include graphical displays of the surface profile, autocovariance function, spectral density function, stability, and repeatability. Comparison with other instruments is also discussed.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A New Calculus for the Treatment of Optical SystemsI Description and Discussion of the Calculus
Jones, R. C. (1941) · Journal of the Optical Society of America · doi:10.1364/josa.31.000488 · Cited by 1,907
Relation Between Surface Roughness and Specular Reflectance at Normal Incidence
Bennett, H. E., & Porteus, J. O. (1961) · Journal of the Optical Society of America · doi:10.1364/josa.51.000123 · Cited by 1,121
A New Calculus for the Treatment of Optical Systems IV
Clark Jones, R. (1942) · Journal of the Optical Society of America · doi:10.1364/josa.32.000486 · Cited by 1,019
Elson, J. M., & Bennett, J. M. (1979) · Journal of the Optical Society of America · doi:10.1364/josa.69.000031 · Cited by 258
Bennett, H. E. (1963) · Journal of the Optical Society of America · doi:10.1364/josa.53.001389 · Cited by 195
Roughness characterization of smooth machined surfaces by light scattering
Stover, J. C. (1975) · Applied Optics · doi:10.1364/ao.14.001796 · Cited by 78
Instrument for Measuring the Roughness of Supersmooth Surfaces
Hildebrand, B. P., Gordon, R., & Allen, E. V. (1974) · Applied Optics · doi:10.1364/ao.13.000177 · Cited by 34
Cited by
A review of interferometry for geometric measurement
Yang, S., & Zhang, G. (2018) · Measurement Science and Technology · doi:10.1088/1361-6501/aad732 · Cited by 190
“The earliest interferometric profiler, proposed by Sommargren [204], adopted single point data acquisition and a mechanical scanner to achieve surface profilometry.”
MethodAn Optical Profilometer for Surface Characterization of Magnetic Media
Wyant, J. C., Koliopoulos, C. L., Bhushan, B., & George, O. E. (1984) · A S L E Transactions · doi:10.1080/05698198408981550 · Cited by 179
Effects on optical systems from interactions with oxygen atoms in low earth orbits
Peters, P. N., Gregory, J. C., & Swann, J. T. (1986) · Applied Optics · doi:10.1364/ao.25.001290 · Cited by 55
Image scanning ellipsometry for measuring nonuniform film thickness profiles
Liu, A.-H., Wayner, P. C., & Plawsky, J. L. (1994) · Applied Optics · doi:10.1364/ao.33.001223 · Cited by 46
Metadata
- Authors
- Sommargren, G. E.
- Venue
- Applied Optics
- Publisher
- Optica Publishing Group
- Published
- 1981-02-15
- Volume
- 20
- Issue
- 4
- Pages
- 610
- ISSN
- 0003-6935 (ISSN-L)
- 1539-4522
- OpenAlex
- W1996778195
- Cited by
- 244
- References
- 7
- FWCI
- 10.16
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Optical heterodyne profilometry. https://app.cochat.ai/papers/10.1364/ao.20.000610
- The paper
- Sommargren, G. E. (1981). Optical heterodyne profilometry. Applied Optics. https://doi.org/10.1364/ao.20.000610
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.