Laser absorption spectroscopy for combustion diagnosis in reactive flows: A review
Open accessThe DOI matches its Crossref record; 73 of the 73 references it cites were found in a registry or an index.
Abstract
Laser absorption spectroscopy (LAS) has been rapidly developed and widely applied to combustion diagnosis in recent decades. As a cost-effective tool for measuring multiple combustion parameters, LAS provides unique properties in terms of accuracy and sensitivity for understanding the reactions and kinetics in reactive flows. Line-of-sight and tomographic LAS techniques have stimulated numerous applications and been proved to be robust for in situ combustion diagnosis in uniform and non-uniform combustion fields, respectively. This review highlights the breakthroughs in the evolution of LAS techniques from the viewpoints of key principles, sensors and instrumentations developed for combustion diagnosis, with particular emphasis on a series of spatially-resolved LAS techniques with their recent applications on obtaining high-fidelity measurement results with minimal intrusion to the practical combustors. Along the way, we note some challenges and requirements for further development of the LAS-based combustion diagnosis.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Solutions of Ill-Posed Problems.
Bell, J. B., Tikhonov, A. N., & Arsenin, V. Y. (1978) · Mathematics of Computation · doi:10.2307/2006360 · Cited by 8,101 · cited 2×
“These problems can be suppressed by using regularization methods (154, 155), such as Truncated Singular Value Decomposition (TSVD) and standard Tikhonov regularization.”
BackgroundMethodEncyclopedia of Analytical Chemistry: Applications, Theory and Instrumentation
(2006) · Wiley eBooks · doi:10.1002/9780470027318 · Cited by 7,403
Principles of Computerized Tomographic Imaging
Kak, A. C., & Slaney, M. (2001) · doi:10.1137/1.9780898719277 · Cited by 5,809
The HITRAN2012 molecular spectroscopic database
Rothman, L. S., Gordon, I. E., Babikov, Y., Barbe, A., Chris Benner, D., Bernath, P. F., Birk, M., Bizzocchi, L., Boudon, V., Brown, L. R., et al. (2013) · Journal of Quantitative Spectroscopy and Radiative Transfer · doi:10.1016/j.jqsrt.2013.07.002 · Cited by 3,255 · cited 1×
“As shown in Figure 1, gas molecules can be fingerprinted in the near- and mid-infrared bands using their absorption characteristics arising from rovibrational transitions and combination bands (32, 33).”
BackgroundThe Use of the L-Curve in the Regularization of Discrete Ill-Posed Problems
Hansen, P. C., & O’Leary, D. P. (1993) · SIAM Journal on Scientific Computing · doi:10.1137/0914086 · Cited by 3,137 · cited 1×
“It should be noted that the traditional λ selection method such as the L-curve criterion presumes the least-square solution is the correct with noise-free data (159), that is, x D x, which is not satisfied by the rank-deficient problem.”
MethodGordon, R., Bender, R., & Herman, G. T. (1970) · Journal of Theoretical Biology · doi:10.1016/0022-5193(70)90109-8 · Cited by 2,791 · cited 1×
“In contrast, algebraic reconstruction technique (ART) is more suitable for dealing with incomplete and irregular sampling (140 – 142), since ART uses multiple repetitions in which the current solution converges toward a better solution.”
BackgroundHITEMP, the high-temperature molecular spectroscopic database
Rothman, L. S., Gordon, I. E., Barber, R. J., Dothe, H., Gamache, R. R., Goldman, A., Perevalov, V. I., Tashkun, S. A., & Tennyson, J. (2010) · Journal of Quantitative Spectroscopy and Radiative Transfer · doi:10.1016/j.jqsrt.2010.05.001 · Cited by 2,285 · cited 1×
“As shown in Figure 1, gas molecules can be fi ngerprinted in the near-and mid-infrared bands using their absorption characteristics arising from rovibrational transitions and combination bands (32, 33).”
BackgroundAndersen, A. (1984) · Ultrasonic Imaging · doi:10.1016/0161-7346(84)90008-7 · Cited by 1,812
Computed Tomography: Principles, Design, Artifacts, and Recent Advances
Hsieh, J. (2015) · doi:10.1117/3.2197756 · Cited by 1,400 · cited 2×
“In principle, the mathematical formulation for linear LAS tomography is similar to the computer tomography that has been extensively employed in clinical diagnosis (131, 135).”
MethodOxy-fuel combustion of solid fuels
Toftegaard, M. B., Brix, J., Jensen, P. A., Glarborg, P., & Jensen, A. D. (2010) · Progress in Energy and Combustion Science · doi:10.1016/j.pecs.2010.02.001 · Cited by 1,146 · cited 2×
“(4) The laser penetrates the target species and the transmitted laser intensity It(t) is measured.”
Background
Cited by
Laser sensors for energy systems and process industries: Perspectives and directions
Farooq, A., Alquaity, A. B. S., Raza, M., Nasir, E. F., Yao, S., & Ren, W. (2022) · Progress in Energy and Combustion Science · doi:10.1016/j.pecs.2022.100997 · Cited by 164
Bioanalytical Applications of Microextraction Techniques: A Review of Reviews
Jalili, V., Barkhordari, A., & Ghiasvand, A. (2020) · Chromatographia · doi:10.1007/s10337-020-03884-1 · Cited by 40
The Application of Spectroscopy Technology in the Monitoring of Microalgae Cells Concentration
Liu, J.-Y., Zeng, L.-H., & Ren, Z.-H. (2021) · Applied Spectroscopy Reviews · doi:10.1080/05704928.2020.1763380 · Cited by 33
Metadata
- Authors
- Liu, C., & Xu, L.
- Venue
- Applied Spectroscopy Reviews
- Publisher
- Informa UK Limited
- Published
- 2018-04-13
- Volume
- 54
- Issue
- 1
- Pages
- 1-44
- ISSN
- 0570-4928 (ISSN-L)
- 1520-569X
- OpenAlex
- W2796705419
- Cited by
- 230
- References
- 73
- FWCI
- 7.71
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.