CoChat

A Finger Volume-Oscillometric Device for Monitoring Ambulatory Blood Pressure: Laboratory and Clinical Evaluations

Imai, Y., Nihei, M., Abe, K., Sasaki, S., Minami, N., Munakata, M., Yumita, S., Onoda, Y., Sekino, H., Yamakoshi, K., Yoshinaga, K. · 1987 · Clinical and Experimental Hypertension. Part A: Theory and Practice
Cited by 50

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

A new portable device for the indirect measurement of ambulatory blood pressure in the finger was successfully applied to normotensive and hypertensive subjects in and outside a ward setting. The device uses the volume-oscillometric technique and, equipped with a microprocessor, permits long-term ambulatory monitoring of indirect systolic and mean blood pressure at desired intervals (once every 1-10 min). Systolic and mean blood pressures obtained by this method were well correlated with those measured by the direct (Oxford) and arm-cuff methods. Systolic and diastolic blood pressure obtained by the volume-oscillometric device were almost identical with those recorded by an arm-cuff. Systolic blood pressure obtained by the volume oscillometric method was, however, significantly lower than that measured by the direct method. The new device has also been used to measure blood pressure during treadmill exercise and ice-water immersion. Mean values of blood pressure and the SD of these averaged for 24 hours, or for every hour, were reproducible when the measurements were repeated under the same condition. The present device is portable, causes minimal noise, can detect rapid change in blood pressure and causes less discomfort when compared to the conventional arm-cuff method. Regular measurements can be made with minimal sleep disturbance. This fully automatic volume-oscillometric device allows reliable 24-hour monitoring of ambulatory blood pressure not only in but also outside a ward setting, and as such is useful for studies of hypertension.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1080/07300077.1987.11978712

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 50

Metadata

Authors
Imai, Y., Nihei, M., Abe, K., Sasaki, S., Minami, N., Munakata, M., Yumita, S., Onoda, Y., Sekino, H., Yamakoshi, K., & Yoshinaga, K.
Venue
Clinical and Experimental Hypertension. Part A: Theory and Practice
Published
1987-01
Volume
9
Issue
12
Pages
2001-2025
ISSN
  • 0148-3927 (ISSN-L)
  • 0730-0077
OpenAlex
W2039354007
Cited by
50
References
1
FWCI
2.31
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: A Finger Volume-Oscillometric Device for Monitoring Ambulatory Blood Pressure: Laboratory and Clinical Evaluations. https://app.cochat.ai/papers/10.1080/07300077.1987.11978712
The paper
Imai, Y., Nihei, M., Abe, K., Sasaki, S., Minami, N., Munakata, M., Yumita, S., Onoda, Y., Sekino, H., Yamakoshi, K., & Yoshinaga, K. (1987). A Finger Volume-Oscillometric Device for Monitoring Ambulatory Blood Pressure: Laboratory and Clinical Evaluations. Clinical and Experimental Hypertension. Part A: Theory and Practice. https://doi.org/10.1080/07300077.1987.11978712

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.