New oscillometric method for indirect measurement of systolic and mean arterial pressure in the human finger. Part 1: Model experiment
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
When the transmural pressure reaches zero, the AC amplitude reaches its maximum.
“When the transmural pressure reaches zero, the AC amplitude reaches its maximum [204,205].”
From Sources of inaccuracy in photoplethysmography for continuous cardiovascular monitoring (2021) · cites this paper as [204]
Cites
Mechanical properties of arteries
Dobrin, P. B. (1978) · Physiological Reviews · doi:10.1152/physrev.1978.58.2.397 · Cited by 746 · see citing works
Noninvasive automatic determination of mean arterial pressure
Ramsey, M. (1979) · Medical and Biological Engineering and Computing · doi:10.1007/bf02440948 · Cited by 287 · see citing works
Mauck, G. W., Smith, C. R., Geddes, L. A., & BOURLAND, J. D. (1980) · Journal of Biomechanical Engineering · doi:10.1115/1.3138195 · Cited by 222 · see citing works
The Direct and Indirect Measurement of Blood Pressure.
(1970) · Annals of Internal Medicine · doi:10.7326/0003-4819-73-1-152_1 · Cited by 191 · see citing works
Mechanics of Distension of Dog Veins and Other Very Thin-Walled Tubular Structures
Moreno, A. H., Katz, A. I., Gold, L. D., et al. (1970) · Circulation Research · doi:10.1161/01.res.27.6.1069 · Cited by 170 · see citing works
Indirect Measurement of Mean Blood Pressure in the Anesthetized Patient
Yelderman, M., & Ream, A. K. (1979) · Anesthesiology · doi:10.1097/00000542-197903000-00022 · Cited by 151 · see citing works
Yamakoshi, K.-I., Shimazu, H., & Togawa, T. (1980) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1980.326616 · Cited by 140 · see citing works
Self-citationYamakoshi, K., Shimazu, H., Shibata, M., & Kamiya, A. (1982) · Medical & Biological Engineering & Computing · doi:10.1007/bf02442798 · Cited by 104 · see citing works
Self-citationArterial wall mechanics and composition and the effects of smooth muscle activation
Cox, R. H. (1975) · American Journal of Physiology-Legacy Content · doi:10.1152/ajplegacy.1975.229.3.807 · Cited by 78 · see citing works
Comparison of carotid artery mechanics in the rat, rabbit, and dog
Cox, R. H. (1978) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.1978.234.3.h280 · Cited by 62 · see citing works
Indirect mean arterial pressure in the anesthetized dog
Geddes, L. A., Combs, W., Denton, W., Whistler, S. J., & BOURLAND, J. D. (1980) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.1980.238.5.h664 · Cited by 59 · see citing works
The direct and indirect measurement of blood pressure
Hill, D. W. (1970) · Medical & Biological Engineering & Computing · doi:10.1007/bf02478236 · Cited by 53 · see citing works
Indirect measurement of instantaneous arterial blood pressure in the rat
Yamakoshi, K., Shimazu, H., & Togawa, T. (1979) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.1979.237.5.h632 · Cited by 50 · see citing works
Self-citationIndirect Mean Blood Pressure in the Anesthetized Pony
Geddes, L. A., Chaffee, V., Whistler, S. J., BOURLAND, J. D., & Tacker, W. A. (1977) · American Journal of Veterinary Research · doi:10.2460/ajvr.1977.38.12.2055 · Cited by 45 · see citing works
Indirect Measurement of Mean Blood Pressure in the Normotensive and Hypotensive Horse
Latshaw, H. S., FESSLER, J. F., Whistler, S. J., & Geddes, L. A. (1979) · Equine Veterinary Journal · doi:10.1111/j.2042-3306.1979.tb01340.x · Cited by 44 · see citing works
MEASUREMENT OF BLOOD CONTENT AND ARTERIAL PRESSURE IN THE HUMAN EAR
Wood, E. H., KNUTSON, J., & Taylor, B. E. (1950) · Mayo Clinic Proceedings · doi:10.1016/s0025-6196(26)04465-4 · Cited by 5 · see citing works
Flagged first, then by citations
Cited by
Sorted by citations
Mobile monitoring with wearable photoplethysmographic biosensors
Asada, H. H., Shaltis, P., Reisner, A., Rhee, S., & Hutchinson, R. C. (2003) · IEEE Engineering in Medicine and Biology Magazine · doi:10.1109/memb.2003.1213624 · Cited by 466 · see citing works
Sources of inaccuracy in photoplethysmography for continuous cardiovascular monitoring
Fine, J., Branan, K. L., Rodriguez, A. J., Boonya-ananta, T., Ajmal, Ramella-Roman, J. C., McShane, M. J., & Coté, G. L. (2021) · Biosensors · doi:10.3390/bios11040126 · Cited by 348 · see citing works
Ursino, M., & Cristalli, C. (1996) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.508540 · Cited by 179 · see citing works
Theoretical study on the effect of sensor contact force on pulse transit time
Teng, X.-F., & Zhang, Y.-T. (2007) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2007.900815 · Cited by 94 · see citing works
- Authors
- Yamakoshi, K., Shimazu, H., Shibata, M., & Kamiya, A.
- Affiliations
- Hokkaido University (JP)
- Venue
- Medical & Biological Engineering & Computing
- Published
- 1982-05
- Volume
- 20
- Issue
- 3
- Pages
- 307-313
- ISSN
- 0140-0118 (ISSN-L)
- 1741-0444
- OpenAlex
- W2003429825
- Cited by
- 129
- References
- 17
- Citations by year
- 2026: 1 · 2025: 1 · 2024: 1 · 2023: 3 · 2022: 2 · 2021: 5 · 2020: 2 · 2019: 3 · 2018: 1 · 2017: 1 · 2016: 2 · 2015: 1 · 2014: 1 · 2013: 4 · 2012: 1
- FWCI
- 4.43
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.springer.com/tdm (tdm)
- Locations
- Medical & Biological Engineering & Computing (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiovascular Health and Disease Prevention
- Health Sciences › Medicine › Surgery › Hemodynamic Monitoring and Therapy
- Keywords
- oscillometric blood pressure measurement, finger arterial pressure, systolic blood pressure, mean arterial pressure, pressure-volume relationship, counterpressure, transmural pressure, plethysmography
- MeSH terms
- Blood Pressure, Blood Volume, Fingers, Humans, Models, Cardiovascular, Oscillometry, Plethysmography, In Vitro Techniques
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review