Biofiltration of Air: A Review
The DOI matches its Crossref record; 28 of the 28 references it cites were found in a registry or an index.
Abstract
In this paper we present a review of the existing air pollution control technologies (APCT), when used essentially for the elimination of volatile organic compounds (VOC). The biotechnologies referred to, bioscrubbers, biotrickling filters and biofilters, are also described. A more detailed review of biofiltration is proposed, presenting the most recent and latest developments achieved in the field of bioprocessing. In particular, the influence of the filter bed, the polluted air flowrates, the pollutants, the pressure drop, bed moisture content, temperature, nutrients, pH and the microorganisms are reviewed. Models of biofiltration are also presented.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Fluid Flow Through Packed Columns
Ergün, Ş. (1952) · Medical Entomology and Zoology · Cited by 6,992
(1988) · Applied Catalysis · doi:10.1016/0166-9834(88)80018-6 · Cited by 2,522
The chemical engineering journal
Kam, E. K. T., & Hughes, R. (1979) · The Chemical Engineering Journal · doi:10.1016/0300-9467(79)80049-0 · Cited by 1,438
Encyclopedia of environmental analysis and remediation
Meyers, R. A. (1998) · Wiley eBooks · Cited by 875
Biofiltration for air pollution control
(1999) · Choice Reviews Online · doi:10.5860/choice.36-4506 · Cited by 870
Biofiltration: An Innovative Air Pollution Control Technology For VOC Emissions
Leson, G., & Winer, A. M. (1991) · Journal of the Air & Waste Management Association · doi:10.1080/10473289.1991.10466898 · Cited by 662
Kinetics of organic compound removal from waste gases with a biological filter
Ottengraf, S. P. P., & Van Den Oever, A. H. C. (1983) · Biotechnology and Bioengineering · doi:10.1002/bit.260251222 · Cited by 433
Cohen, Y. (2001) · Bioresource Technology · doi:10.1016/s0960-8524(00)00074-2 · Cited by 299
Biofilm removal caused by chemical treatments
Chen, X., & Stewart, P. S. (2000) · Water Research · doi:10.1016/s0043-1354(00)00187-1 · Cited by 271
Biofiltration of mixtures of hydrophilic and hydrophobic volatile organic compounds
Mohseni, M., & Allen, D. G. (2000) · Chemical Engineering Science · doi:10.1016/s0009-2509(99)00420-0 · Cited by 233
Cited by
Technologies for the removal of phenol from fluid streams: A short review of recent developments
Busca, G., Berardinelli, S., Resini, C., & Arrighi, L. (2008) · Journal of Hazardous Materials · doi:10.1016/j.jhazmat.2008.03.045 · Cited by 1,292
Adsorptive remediation of environmental pollutants using novel graphene-based nanomaterials
Wang, S., Sun, H., Ang, H. M., & Tadé, M. O. (2013) · Chemical Engineering Journal · doi:10.1016/j.cej.2013.04.070 · Cited by 729
Bioreactors for treatment of VOCs and odours – A review
Mudliar, S., Giri, B., Padoley, K., Satpute, D., Dixit, R., Bhatt, P., Pandey, R., Juwarkar, A., & Vaidya, A. (2010) · Journal of Environmental Management · doi:10.1016/j.jenvman.2010.01.006 · Cited by 532
Challenges and solutions for biofiltration of hydrophobic volatile organic compounds
Cheng, Y., He, H., Yang, C., Zeng, G., Li, X., Chen, H., & Yu, G. (2016) · Biotechnology Advances · doi:10.1016/j.biotechadv.2016.06.007 · Cited by 406
Biological treatment of indoor air for VOC removal: Potential and challenges
Guieysse, B., Hort, C., Platel, V., Munoz, R., Ondarts, M., & Revah, S. (2008) · Biotechnology Advances · doi:10.1016/j.biotechadv.2008.03.005 · Cited by 308
Biomass accumulation and control strategies in gas biofiltration
Yang, C., Chen, H., Zeng, G., Yu, G., & Luo, S. (2010) · Biotechnology Advances · doi:10.1016/j.biotechadv.2010.04.002 · Cited by 266
Pudi, A., Rezaei, M., Signorini, V., Andersson, M. P., Baschetti, M. G., & Mansouri, S. S. (2022) · Separation and Purification Technology · doi:10.1016/j.seppur.2022.121448 · Cited by 258
Experimental and DFT study on the adsorption of VOCs on activated carbon/metal oxides composites
Zhou, K., Ma, W., Zeng, Z., Ma, X., Xu, X., Guo, Y., Li, H., & Li, L. (2019) · Chemical Engineering Journal · doi:10.1016/j.cej.2019.04.218 · Cited by 248
A Comparative Analysis of Odour Treatment Technologies in Wastewater Treatment Plants
Estrada, J. M., Kraakman, N. J. R. B., Muñoz, R., & Lebrero, R. (2011) · Environmental Science & Technology · doi:10.1021/es103478j · Cited by 209
A review on activated carbon adsorption for volatile organic compounds (VOCs)
Pui, W. K., Yusoff, R., & Aroua, M. K. (2019) · Reviews in Chemical Engineering · doi:10.1515/revce-2017-0057 · Cited by 191
Botanical biofiltration of indoor gaseous pollutants – A mini-review
Soreanu, G., Dixon, M., & Darlington, A. (2013) · Chemical Engineering Journal · doi:10.1016/j.cej.2013.06.074 · Cited by 179
VOLATILE ORGANIC COMPOUNDS REMOVAL METHODS: A REVIEW
Bouchaala (2012) · American Journal of Biochemistry and Biotechnology · doi:10.3844/ajbbsp.2012.220.229 · Cited by 177
“…are less treatment efficiency at high concentrations of pollutants, extremely large size of bioreactor challenges space constraints to require close control of operating conditions and limited life of packing and clogging of the medium due to particulate medium (Delhomenie and Heitz, 2005).”
BackgroundInfluentialTwo-phase partitioning bioreactors for treatment of volatile organic compounds
Muñoz, R., Villaverde, S., Guieysse, B., & Revah, S. (2007) · Biotechnology Advances · doi:10.1016/j.biotechadv.2007.03.005 · Cited by 175
“Among the technologies available for air pollution control from stationary sources (Table 2), biological systems (e.g. biofilters, biotrickling filters) represent cost-effective solutions for treating low concentrations of pollutants (Delhoménie and Heitz, 2005; Moo-Young and Chisti, 1994).”
BackgroundInfluentialEmissions, measurement, and control of odor in livestock farms: A review
Wang, Y.-C., Han, M.-F., Jia, T.-P., Hu, X.-R., Zhu, H.-Q., Tong, Z., Lin, Y.-T., Wang, C., Liu, D.-Z., Peng, Y.-Z., et al. (2021) · Science of The Total Environment · doi:10.1016/j.scitotenv.2021.145735 · Cited by 174
Muñoz, R., Daugulis, A. J., Hernández, M., & Quijano, G. (2012) · Biotechnology Advances · doi:10.1016/j.biotechadv.2012.08.009 · Cited by 168
“this low emission share, VOC emissions represent a major environmental and human health problem sincemost VOCs can be toxic depending on the concentration and exposure time and they also contribute to substantial damage to natural ecosystems (Delhomenie and Heitz, 2005; Hernandez et al., 2010; Muñoz et al., 2007).”
BackgroundVan der Heyden, C., Demeyer, P., & Volcke, E. I. P. (2015) · Biosystems Engineering · doi:10.1016/j.biosystemseng.2015.04.002 · Cited by 167
“Reference: [1] EEA. (2014)* [2] Melse, Hol, et al.”
Pachaiappan, R., Cornejo-Ponce, L., Rajendran, R., Manavalan, K., Femilaa Rajan, V., & Awad, F. (2022) · Bioengineered · doi:10.1080/21655979.2022.2050538 · Cited by 161
“Whereas the peat holds a high specific area with less amount of intrinsic nutrients and microorganisms [15].”
BackgroundInfluentialA review of green systems within the indoor environment
Moya, T. A., van den Dobbelsteen, A., Ottelé, M., & Bluyssen, P. M. (2019) · Indoor and Built Environment · doi:10.1177/1420326x18783042 · Cited by 160
Biotechnology Progress for Removal of Indoor Gaseous Formaldehyde
Shao, Y., Wang, Y., Zhao, R., Chen, J., Zhang, F., Linhardt, R. J., & Zhong, W. (2020) · Applied Microbiology and Biotechnology · doi:10.1007/s00253-020-10514-1 · Cited by 76
Metadata
- Authors
- Delhoménie, M.-C., & Heitz, M.
- Venue
- Critical Reviews in Biotechnology
- Publisher
- Informa UK Limited
- Published
- 2005-01
- Volume
- 25
- Issue
- 1-2
- Pages
- 53-72
- ISSN
- 0738-8551 (ISSN-L)
- 1549-7801
- OpenAlex
- W2027028239
- Cited by
- 409
- References
- 28
- FWCI
- 9.86
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.