Cited by 63Metallurgical Processes and ThermodynamicsIron and Steelmaking ProcessesChemical Looping and Thermochemical Processes

Vacuum Carbothermic Reduction of Al2O3, BeO, MgO-CaO, TiO2, ZrO2, HfO2 + ZrO2, SiO2, SiO2 + Fe2O3, and GeO2to the Metals. A Thermodynamic Study

Halmann, M., Frei, A., Steinfeld, A.·2011·Mineral Processing and Extractive Metallurgy Review

Abstract

Thermochemical equilibrium calculations are carried out to elucidate improved conditions for the production of Al, Si, FeSi, Ti, Mg, Hf, Zr, Be, and Ge by the high-temperature carbothermic reduction of their oxides, and for the production of Mg by the silicothermic reduction of MgO–CaO. The onset temperature for the formation of free Al, Be, Si, Ti, Mg, Hf, and Zr in the gas phase is considerably lowered by decreasing the total pressure, enabling their vacuum distillation. An important prediction of vacuum operation is the suppression of undesired by-products, such as Al-carbide, Al4C3, and the Al-oxycarbides Al2OC and Al4O4C. These species considerably interfere in the carbothermic Al production at an ambient pressure, as shown in preliminary experiments using induction furnace irradiation. CO coproduced in these reactions may be water-gas shifted to syngas and further processed to hydrogen and liquid fuels.

Integrity signals

Registry

Crossref · 10.1080/08827508.2010.530723

Cites

17 of 17 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • Halmann et al. found that vacuum condition facilitates the decline of reaction temperature from 1600°C to 900°C with pressure decreasing from 1 bar to 10^-5 bar.

    “Halmann et al. also investigated the thermodynamics for the reactants of Fe2O3, SiO 2 , and C, and found that vacuum condition also facilitates the decline of reaction temperature (from 1600°C to 900°C with pressure decreasing from 1 bar to 10 -5 bar). 126”

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Authors
Halmann, M., Frei, A., & Steinfeld, A.
Affiliations
  • Weizmann Institute of Science (IL)
  • Paul Scherrer Institute (CH)
Corresponding author
Halmann, M.
Venue
Mineral Processing and Extractive Metallurgy Review
Published
2011-10
Volume
32
Issue
4
Pages
247-266
ISSN
  • 0882-7508 (ISSN-L)
  • 1547-7401
OpenAlex
W1947343779
Cited by
63
References
17
Citations by year
2026: 1 · 2025: 3 · 2024: 4 · 2023: 6 · 2022: 3 · 2021: 2 · 2020: 4 · 2019: 6 · 2018: 5 · 2017: 4 · 2016: 10 · 2015: 3 · 2014: 6 · 2013: 5 · 2012: 1
FWCI
6.80
Type
journal article
Language
en
Open access
closed
Locations
  • Mineral Processing and Extractive Metallurgy Review (publishedVersion)
  • DORA PSI (Paul Scherrer Institute) (submittedVersion)
Topics
  • Physical Sciences › Engineering › Mechanical Engineering › Metallurgical Processes and Thermodynamics
  • Physical Sciences › Engineering › Mechanical Engineering › Iron and Steelmaking Processes
  • Physical Sciences › Engineering › Biomedical Engineering › Chemical Looping and Thermochemical Processes
Keywords
carbothermal reduction, vacuum distillation, metal oxide reduction, thermodynamic equilibrium, aluminum production, silicon production, titanium production, magnesium production, zirconium production, beryllium production, silicothermic reduction, Al4C3, high-temperature reduction

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review