The DOI matches its Crossref record.
Low Flow Rate Sharp Cut Impactors for Indoor Air Sampling: Design and Calibration
Open accessAbstract
Two single round nozzle impactors have been developed for use in Harvard’s indoor air pollution health study. Both impactors operate at flow rates of 4 L/m and are nearly identical, differing only in their cut sizes of 2.5 μm and 10 μm aerodynamic diameters. Two identical cascaded stages of the same cut size are used to obtain sharp cut-off characteristics. The particles are deposited on impaction plates made of oil impregnated, porous material to reduce particle bounce and are discarded. Only the particles collected on the afterfilter are analyzed. Special care has been taken to collect the particles uniformly on the afterfilter to aid in particle analysis. The jmpactors were calibrated with a vibrating orifice monodisperse aerosol generator. However, due to the sharp cut of the impactors, doublets and triplets in the calibration aerosols, even in small quantities, gave erroneous calibration curves. Therefore, the number of doublets and triplets in the challenging aerosols were measured and appropriate corrections made to the calibration curves.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Characterization of Indoor Particle Sources Using Continuous Mass and Size Monitors
Long, C. M., Suh, H. H., & Koutrakis, P. (2000) · Journal of the Air & Waste Management Association · doi:10.1080/10473289.2000.10464154 · Cited by 364
Characterization of indoor particle sources: A study conducted in the metropolitan Boston area.
Abt, E., Suh, H. H., Allen, G., & Koutrakis, P. (2000) · Environmental Health Perspectives · doi:10.1289/ehp.0010835 · Cited by 332
Assessment of exposure to traffic related air pollution of children attending schools near motorways
Janssen, N. A. H., van Vliet, P. H. N., Aarts, F., Harssema, H., & Brunekreef, B. (2001) · Atmospheric Environment · doi:10.1016/s1352-2310(01)00144-3 · Cited by 326
Fischer, P. H., Hoek, G., van Reeuwijk, H., Briggs, D. J., Lebret, E., van Wijnen, J. H., Kingham, S., & Elliott, P. E. (2000) · Atmospheric Environment · doi:10.1016/s1352-2310(00)00067-4 · Cited by 277
Bateson, T. F., & Schwartz, J. (1999) · Epidemiology · doi:10.1097/00001648-199909000-00013 · Cited by 260
Metadata
- Authors
- Marple, V. A., Rubow, K. L., Turner, W., & Spengler, J. D.
- Venue
- JAPCA
- Publisher
- Informa UK Limited
- Published
- 1987-11
- Volume
- 37
- Issue
- 11
- Pages
- 1303-1307
- ISSN
- 0894-0630 (ISSN-L)
- OpenAlex
- W2092949470
- Cited by
- 241
- References
- 0
- FWCI
- 2.67
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Low Flow Rate Sharp Cut Impactors for Indoor Air Sampling: Design and Calibration. https://app.cochat.ai/papers/10.1080/08940630.1987.10466325
- The paper
- Marple, V. A., Rubow, K. L., Turner, W., & Spengler, J. D. (1987). Low Flow Rate Sharp Cut Impactors for Indoor Air Sampling: Design and Calibration. JAPCA. https://doi.org/10.1080/08940630.1987.10466325
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.