Effect of cerium oxide nanoparticles on inflammation in vascular endothelial cells
Open accessThe DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
Because vascular endothelial cell inflammation is critical in the development of cardiovascular pathology, we hypothesized that direct exposure of human aortic endothelial cells (HAECs) to ultrafine particles induces an inflammatory response. To test the hypothesis, we incubated HAECs for 4 h with different concentrations (0.001-50 microg/ml) of CeO(2) nanoparticles and subsequently measured mRNA levels of the three inflammatory markers intercellular adhesion molecule 1 (ICAM-1), interleukin (IL)-8, and monocyte chemotactic protein (MCP-1) using real-time polymerase chain reaction (PCR). Ceria nanoparticles caused very little inflammatory response in HAECs, even at the highest dose. This material is apparently rather benign in comparison with Y(2)O(3) and ZnO nanoparticles that we have studied previously. These results suggest that inflammation in HAECs following acute exposure to metal oxide nanoparticles depends strongly on particle composition.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Cedervall, T., Lynch, I., Lindman, S., Berggård, T., Thulin, E., Nilsson, H., Dawson, K. A., & Linse, S. (2007) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0608582104 · Cited by 3,281
Passage of inhaled particles into the blood circulation in humans
Nemmar, A., Hoet, P. H. M., Vanquickenborne, B., Dinsdale, D., Thomeer, M., Hoylaerts, M. F., Vanbilloen, H., Mortelmans, L., & Nemery, B. (2002) · Circulation · doi:10.1161/hc0402.104118 · Cited by 1,719
Allen, L. T., Tosetto, M., Miller, I. S., O’Connor, D. P., Penney, S. C., Lynch, I., Keenan, A. K., Pennington, S. R., Dawson, K. A., & Gallagher, W. M. (2006) · Biomaterials · doi:10.1016/j.biomaterials.2006.01.019 · Cited by 245
Cited by
Synthesis, characterization, applications, and challenges of iron oxide nanoparticles
Ali, A., Zafar, H., Zia, M., ul Haq, I., Phull, A. R., Ali, J. S., & Hussain, A. (2016) · Nanotechnology, Science and Applications · doi:10.2147/nsa.s99986 · Cited by 1,591
Pharmacological potential of cerium oxide nanoparticles
Celardo, I., Pedersen, J. Z., Traversa, E., & Ghibelli, L. (2011) · Nanoscale · doi:10.1039/c0nr00875c · Cited by 1,151
A Comprehensive Review of Glucose Biosensors Based on Nanostructured Metal-Oxides
Rahman, M. M., Ahammad, A. J. S., Jin, J.-H., Ahn, S. J., & Lee, J.-J. (2010) · Sensors · doi:10.3390/s100504855 · Cited by 762
“It also shows large surface area like other nanostructured materials and good biocompatibility [165-173].”
BackgroundSelf-citationManne, N. D. P. K., Arvapalli, R., Graffeo, V. A., Bandarupalli, V. V. K., Shokuhfar, T., Patel, S., Rice, K. M., Ginjupalli, G. K., & Blough, E. R. (2017) · Cellular Physiology and Biochemistry · doi:10.1159/000479540 · Cited by 702
Cerium Oxide Nanoparticles: Applications and Prospects in Nanomedicine
Das, S., Dowding, J. M., Klump, K. E., McGinnis, J. F., Self, W., & Seal, S. (2013) · Nanomedicine · doi:10.2217/nnm.13.133 · Cited by 561
Metadata
- Authors
- Gojova, A., Lee, J.-T., Jung, H. S., Guo, B., Barakat, A. I., & Kennedy, I. M.
- Venue
- Inhalation Toxicology
- Publisher
- Informa UK Limited
- Published
- 2009-06-30
- Volume
- 21
- Issue
- sup1
- Pages
- 123-130
- ISSN
- 0895-8378 (ISSN-L)
- 1091-7691
- OpenAlex
- W2146359376
- Cited by
- 101
- References
- 3
- FWCI
- 4.15
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Effect of cerium oxide nanoparticles on inflammation in vascular endothelial cells. https://app.cochat.ai/papers/10.1080/08958370902942582
- The paper
- Gojova, A., Lee, J.-T., Jung, H. S., Guo, B., Barakat, A. I., & Kennedy, I. M. (2009). Effect of cerium oxide nanoparticles on inflammation in vascular endothelial cells. Inhalation Toxicology. https://doi.org/10.1080/08958370902942582
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.