The DOI matches its Crossref record; 22 of the 22 references it cites were found in a registry or an index.
Comparative Study of Active Thermography Techniques for the Nondestructive Evaluation of Honeycomb Structures
Open accessAbstract
In this article, the theoretical and experimental aspects of three active thermography approaches: pulsed thermography (PT), lock-in thermography (LT), and vibrothermography (VT), are discussed in relation to the nondestructive evaluation (NDE) of honeycomb sandwich structures. For this purpose, two standard specimens with simulated defects (delaminations, core unbonds, excessive adhesive, and crushed core) were tested, and results were processed, examined, and compared. As will be pointed out, the similarities and differences between these active approaches allow conclusions to be made about the most suitable approach for a particular application. In addition, results from NDE inspection by X-rays and c-scan ultrasounds are provided and discussed for reference.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Carslaw, H. S., & Jaeger, J. C. (1947) · International Linear Collider · Cited by 19,877
Tranter, C. J. (1959) · Journal of the Mechanics and Physics of Solids · doi:10.1016/0022-5096(59)90029-8 · Cited by 18,388
An algorithm for the machine calculation of complex Fourier series
Cooley, J. W., & Tukey, J. W. (1965) · Mathematics of Computation · doi:10.1090/s0025-5718-1965-0178586-1 · Cited by 13,154
The Fourier Transform and Its Applications
Bracewell, R., & Kahn, P. B. (1966) · American Journal of Physics · doi:10.1119/1.1973431 · Cited by 5,737
Theory and Practice of Infrared Technology for Nondestructive Testing
Maldague, X. (2001) · Cited by 1,657
Self-citationPulse phase infrared thermography
Maldague, X., & Marinetti, S. (1996) · Journal of Applied Physics · doi:10.1063/1.362662 · Cited by 1,019
Self-citationRajic, N. (2002) · Composite Structures · doi:10.1016/s0263-8223(02)00161-7 · Cited by 701
Recent advances in the use of infrared thermography
Meola, C., & Carlomagno, G. M. (2004) · Measurement Science and Technology · doi:10.1088/0957-0233/15/9/r01 · Cited by 525
Proceedings of IEEE Sensors 2004
(2004) · Proceedings of IEEE Sensors, 2004. · doi:10.1109/icsens.2004.1426074 · Cited by 430
Lock-in thermography for nondestructive evaluation of materials
Wu, D., & Busse, G. (1998) · Revue Générale de Thermique · doi:10.1016/s0035-3159(98)80047-0 · Cited by 350
Cited by
Pulsed thermographic inspection of CFRP structures: experimental results and image analysis tools
Theodorakeas, P., Avdelidis, N. P., Ibarra-Castanedo, C., Koui, M., & Maldague, X. (2014) · SPIE Proceedings · doi:10.1117/12.2044687 · Cited by 17
Self-citation
Metadata
- Authors
- Ibarra-Castanedo, C., Piau, J.-M., Guilbert, S., Avdelidis, N. P., Genest, M., Bendada, A., & Maldague, X. P. V.
- Venue
- Research in Nondestructive Evaluation
- Publisher
- Informa UK Limited
- Published
- 2009-01-28
- Volume
- 20
- Issue
- 1
- Pages
- 1-31
- ISSN
- 0934-9847 (ISSN-L)
- 1432-2110
- OpenAlex
- W1970360506
- Cited by
- 296
- References
- 22
- FWCI
- 11.63
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Comparative Study of Active Thermography Techniques for the Nondestructive Evaluation of Honeycomb Structures. https://app.cochat.ai/papers/10.1080/09349840802366617
- The paper
- Ibarra-Castanedo, C., Piau, J.-M., Guilbert, S., Avdelidis, N. P., Genest, M., Bendada, A., & Maldague, X. P. V. (2009). Comparative Study of Active Thermography Techniques for the Nondestructive Evaluation of Honeycomb Structures. Research in Nondestructive Evaluation. https://doi.org/10.1080/09349840802366617
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.