CoChat

Pulsed thermographic inspection of CFRP structures: experimental results and image analysis tools

Theodorakeas, P., Avdelidis, N. P., Ibarra-Castanedo, C., Koui, M., Maldague, X. · 2014 · SPIE Proceedings

The DOI matches its Crossref record; 15 of the 18 references it cites were found in a registry or an index.

Abstract

In this study, three different CFRP specimens with internal artificial delaminations of various sizes and located at different depths were investigated by means of Pulsed Thermography (PT) under laboratory conditions. The three CFRP panels, having the same thickness and defects characteristics but with a different shape (planar, trapezoid and curved), were assessed after applying various signal processing tools on the acquired thermal data (i.e. Thermographic Signal Reconstruction, Pulsed Phase Thermography and Principal Component Thermography). The effectiveness of the above processing tools was initially evaluated in a qualitative manner, comparing the imaging outputs and the information retrieval in terms of defect detectability enhancement and noise reduction. Simultaneously, the produced defect detectability was evaluated through Signal-to-Noise Ratio (SNR) computations, quantifying the image quality and the intensity contrast produced between the defected area and the adjacent background area of the test panel. From the results of this study, it can be concluded that the implementation of PT along with the application of advanced signal processing algorithms can be a useful technique for NDT assessment, providing enhanced qualitative information. Nevertheless, SNR analysis showed that despite the enhanced visibility resulting from these algorithms, these can be properly applied in order to retrieve the best possible information according to the user’s demands.

Overview

Integrity signals

Registry

Crossref · 10.1117/12.2044687

Cites

15 of 15 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

Show all 15 references

Cited by

See all 17

Metadata

Authors
Theodorakeas, P., Avdelidis, N. P., Ibarra-Castanedo, C., Koui, M., & Maldague, X.
Affiliations
  • National Technical University of Athens (GR)
  • Université Laval (CA)
Venue
SPIE Proceedings
Publisher
SPIE
Published
2014-03-08
Volume
9062
Pages
90620F
ISSN
0277-786X (ISSN-L)
OpenAlex
W2009767316
Cited by
17
References
18
Citations by year
2025: 1 · 2023: 2 · 2021: 2 · 2020: 1 · 2019: 1 · 2018: 4 · 2017: 1 · 2016: 2 · 2015: 3
FWCI
6.59
Type
conference paper
Language
en
Open access
closed
Locations
Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE (publishedVersion)
Topics
  • Physical Sciences › Engineering › Mechanics of Materials › Thermography and Photoacoustic Techniques
  • Physical Sciences › Engineering › Mechanical Engineering › Non-Destructive Testing Techniques
  • Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Infrared Thermography in Medicine
Keywords
pulsed thermography, carbon fiber reinforced polymer, delamination detection, non-destructive testing, thermographic signal reconstruction, pulsed phase thermography, principal component thermography, signal-to-noise ratio, defect detectability, image analysis

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Pulsed thermographic inspection of CFRP structures: experimental results and image analysis tools. https://app.cochat.ai/papers/10.1117/12.2044687
The paper
Theodorakeas, P., Avdelidis, N. P., Ibarra-Castanedo, C., Koui, M., & Maldague, X. (2014). Pulsed thermographic inspection of CFRP structures: experimental results and image analysis tools. SPIE Proceedings. https://doi.org/10.1117/12.2044687

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.