Single-photon avalanche diodes for the near-infrared range: detector and circuit issues
The DOI matches its Crossref record.
Abstract
Recently developed InGaAs/InP devices suitable as single-photon avalanche diodes (SPADs) in the near-infrared range provide good detection efficiency and low time jitter, together with fairly low dark-count rate at moderately low temperature. However, the overall performance is still severely limited by the afterpulsing effect (due to carriers trapped in deep levels during the avalanche and later released). Experimental studies and speculations aiming to improve the overall performance are here presented. The photon detection efficiency is characterized and the primary dark-count rate is investigated, taking into account thermal generation in the InGaAs layer (absorption layer) and trap-assisted tunneling in the InP layer (multiplication layer). Experimental investigations on the afterpulsing are reported. Improvements obtainable with existing devices by selecting proper operating conditions and circuit solutions are presented and discussed. In order to gain a better insight in the design of new devices, the effectiveness of trapping levels as a function of their location and of the electric field distribution is studied by computer simulation. The fundamental role played by the front-end circuits is assessed and demonstrated, in particular as concerns picosecond photon timing for a SPAD operating in gated-mode with ultrafast gate-on and gate-off transitions.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Invited Review Article: Single-photon sources and detectors
Eisaman, M. D., Fan, J., Migdall, A., & Polyakov, S. V. (2011) · Review of Scientific Instruments · doi:10.1063/1.3610677 · Cited by 1,358
Advances in InGaAs/InP single-photon detector systems for quantum communication
Zhang, J., Itzler, M. A., Zbinden, H., & Pan, J.-W. (2015) · Light: Science & Applications · doi:10.1038/lsa.2015.59 · Cited by 436
Single-photon generation and detection
Buller, G. S., & Collins, R. J. (2010) · Measurement Science and Technology · doi:10.1088/0957-0233/21/1/012002 · Cited by 268
New frontiers in time-domain diffuse optics, a review
Pifferi, A., Contini, D., Mora, A. D., Farina, A., Spinelli, L., & Torricelli, A. (2016) · Journal of Biomedical Optics · doi:10.1117/1.jbo.21.9.091310 · Cited by 245
Self-citationHigh performance planar germanium-on-silicon single-photon avalanche diode detectors
Vines, P., Kuzmenko, K., Kirdoda, J., Dumas, D. C. S., Mirza, M. M., Millar, R. W., Paul, D. J., & Buller, G. S. (2019) · Nature Communications · doi:10.1038/s41467-019-08830-w · Cited by 195
Metadata
- Authors
- Tosi, A., Mora, A. D., Zappa, F., & Cova, S.
- Venue
- Journal of Modern Optics
- Publisher
- Informa UK Limited
- Published
- 2009-01-20
- Volume
- 56
- Issue
- 2-3
- Pages
- 299-308
- ISSN
- 0950-0340 (ISSN-L)
- 1362-3044
- OpenAlex
- W2032578512
- Cited by
- 69
- References
- 0
- FWCI
- 7.49
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Single-photon avalanche diodes for the near-infrared range: detector and circuit issues. https://app.cochat.ai/papers/10.1080/09500340802263075
- The paper
- Tosi, A., Mora, A. D., Zappa, F., & Cova, S. (2009). Single-photon avalanche diodes for the near-infrared range: detector and circuit issues. Journal of Modern Optics. https://doi.org/10.1080/09500340802263075
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.