The DOI matches its Crossref record.
Variables influencing Multiplate™ whole blood impedance platelet aggregometry and turbidimetric platelet aggregation in healthy individuals
Abstract
We investigated the relationship between impedance platelet aggregometry (IPA) as measured by the Multiplate system and turbidimetric platelet aggregation (TPA) induced by ADP, arachidonic acid (AA), and collagen; blood cell counts; platelet function analyzer (PFA-100) closure times (CT), and von Willebrand factor (VWF) in 120 well-characterized healthy individuals. Pre-analytical and analytical conditions were standardized comprehensively. Analytical reliability of IPA and TPA and the influence of pre-analytical variables on assay results were also examined. IPA and TPA did not change significantly between 0.5 and 5 hours after blood collection when samples were stored at room temperature. TPA and IPA showed significantly greater intra-assay imprecision than respective TPA induced by the same agonists. Intra-individual variation did not differ significantly between IPA and TPA. The lower limits of reference range (2.5th percentiles) of AAIPA, ADPIPA and collagen IPA determined AM were 37, 20 and 40 AU, respectively. ADPIPA showed significantly lower maximum aggregation values than AAIPA and collagen IPA (P < 0.0001). There were no significant differences in any parameter between males and females. No significant differences between blood group 0 and non-0 individuals were noted with respect to IPA and TPA. IPA did not change significantly during the day. In contrast, TPA measured PM was significantly lower than corresponding values determined a.m. (p < 0.0001). CEPI-CT, CADP-CT and leukocyte counts increased significantly from a.m. to p.m. (P = 0.008 and P > 0.0001, respectively). Donors had significantly greater IPA induced by any agonist than non-donors (P-values < 0.0001, 0.0001 and 0.001, respectively), whereas TPA was not significantly different between donors and non-donors. IPA did not correlate significantly with TPA nor with PFA-100 CT. ADPIPA and collagen IPA correlated significantly with platelet count. TPA was not associated with platelet count. An inverse significant correlation was observed between TPA induced by any agonist and leukocyte count, whereas leukocyte count did not influence IPA. CEPI-CT and CADP-CT correlated significantly with VWF:CBA and with each other but not with TPA. We concluded that IPA and TPA measure different aspects of platelet function. IPA results reflect interactions between platelets, red and white cells, while TPA does not. This explains discrepancies in associations of IPA and TPA with cell counts, time of day and blood donation. The clinical significance of IPA determined using the Multiplate device remains to be determined in studies on patients with platelet dysfunction and under treatment with antiplatelet agents.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Effects of pantoprazole and esomeprazole on platelet inhibition by clopidogrel
Siller-Matula, J. M., Spiel, A. O., Lang, I. M., Kreiner, G., Christ, G., & Jilma, B. (2009) · American Heart Journal · doi:10.1016/j.ahj.2008.09.017 · Cited by 397
RAHE‐MEYER, N., WINTERHALTER, M., BODEN, A., FROEMKE, C., PIEPENBROCK, S., CALATZIS, A., & SOLOMON, C. (2009) · Acta Anaesthesiologica Scandinavica · doi:10.1111/j.1399-6576.2008.01845.x · Cited by 147
Metadata
- Authors
- Seyfert, U. T., Haubelt, H., Vogt, A., & Hellstern, P.
- Venue
- Platelets
- Publisher
- Informa UK Limited
- Published
- 2007-01
- Volume
- 18
- Issue
- 3
- Pages
- 199-206
- ISSN
- 0953-7104 (ISSN-L)
- 1369-1635
- OpenAlex
- W2109695444
- Cited by
- 162
- References
- 0
- FWCI
- 7.95
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Variables influencing Multiplate™ whole blood impedance platelet aggregometry and turbidimetric platelet aggregation in healthy individuals. https://app.cochat.ai/papers/10.1080/09537100600944277
- The paper
- Seyfert, U. T., Haubelt, H., Vogt, A., & Hellstern, P. (2007). Variables influencing Multiplate™ whole blood impedance platelet aggregometry and turbidimetric platelet aggregation in healthy individuals. Platelets. https://doi.org/10.1080/09537100600944277
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.