Prediction of severe illness due to COVID-19 based on an analysis of initial Fibrinogen to Albumin Ratio and Platelet count

Open access
Bi, Xiaojie, SU, Zhengxian, Yan, Haixi, Du, Juping, Wang, Jing, Chen, Linping, Peng, Minfei, Chen, Shiyong, Shen, Bo, Li, Jun · 2020 · Platelets
Cited by 166

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

Concomitant coagulation disorder can occur in severe patients withCOVID-19, but in-depth studies are limited. This study aimed to describe the parameters of coagulation function of patients with COVID-19 and reveal the risk factors of developing severe disease. This study retrospectively analyzed 113patients with SARS-CoV-2 infection in Taizhou Public Health Center. Clinical characteristics and indexes of coagulation function were collected. A multivariate Cox analysis was performed to identify potential biomarkers for predicting disease progression. Based on the results of multivariate Cox analysis, a Nomogram was built and the predictive accuracy was evaluated through the calibration curve, decision curve, clinical impact curve, and Kaplan–Meier analysis. Sensitivity, specificity, predictive values were calculated to assess the clinical value. The data showed that Fibrinogen, FAR, and D-dimer were higher in the severe patients, while PLTcount, Alb were much lower. Multivariate Cox analysis revealed that FAR and PLT count were independent risk factors for disease progression. The optimal cutoff values for FAR and PLT count were 0.0883 and 135*109/L, respectively. The C-index [0.712 (95% CI = 0.610–0.814)], decision curve, clinical impact curve showed that Nomogram could be used to predict the disease progression. In addition, the Kaplan–Meier analysis revealed that potential risk decreased in patients with FAR<0.0883 and PLT count>135*109/L.The model showed a good negative predictive value [(0.9474 (95%CI = 0.845–0.986)].This study revealed that FAR and PLT count were independent risk factors for severe illness and the severity of COVID-19 might be excluded when FAR<0.0883 and PLT count>135*109/L.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1080/09537104.2020.1760230

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

Metadata

Authors
Bi, X., SU, Z., Yan, H., Du, J., Wang, J., Chen, L., Peng, M., Chen, S., Shen, B., & Li, J.
Venue
Platelets
Published
2020-05-05
Volume
31
Issue
5
Pages
674-679
ISSN
  • 0953-7104 (ISSN-L)
  • 1369-1635
OpenAlex
W3022324734
Cited by
166
References
1
FWCI
4.56
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.