The DOI matches its Crossref record.
Reliability of inclinometer and goniometric measurements of hip extension flexibility using the modified Thomas test
Abstract
Phyllis A Clapis PT, DHSc, OCSa, Susan Mercik Davis DPT, PT, MSb* & Ross Otto Davis MSPTca Associate Professor, Department of Physical Therapy, American International College, Springfield, MA, USAb Assistant Professor, Department of Physical Therapy, American International College, Springfield, MA, USAc Senior Physical Therapist, Gentiva Home Care, Farmington, CT, USA† Correspondence: Susan Mercik Davis, Department of Physical Therapy, American International College, 1000 State Street, Springfield, MA 01109 smdrod99@cox.netOur objectives were to examine interrater reliability for inclinometer and goniometric measurements of hip extension flexibility and the intra- and interrater reliability between instruments when measuring hip extension flexibility with the modified Thomas test. The modified Thomas test is frequently used by clinicians to assess hip extension flexibility. Studies examining the reliability of measures of the modified Thomas test are limited. This study included 42 healthy subjects. The modified Thomas test was performed on each subject to quantify hip extension flexibility by using an inclinometer and a goniometer. High interrater reliability was determined for each instrument (r=0.91–0.93; ICC=0.89–0.92). High intrarater parallel-forms reliability was found for each examiner between the instruments (r=0.089–0.92; ICC=0.91–0.93). High interrater parallel-forms reliability also was found between instruments (r=0.86–0.93; ICC=0.86–0.92). The high correlations obtained in this study suggest that the inclinometer and the goniometer are reliable instruments for measuring hip extension flexibility. The results also indicate that the two instruments can be used interchangeably for measuring hip extension flexibility.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Clinical Reliability and Usability of Smartphone Goniometers for Hip Range of Motion Measurement
Takeda, Y., & Furukawa, K. (2022) · Journal of Physical Therapy Science · doi:10.1589/jpts.34.433 · Cited by 10
Metadata
- Authors
- Clapis, P. A., Davis, S. M., & Davis, R. O.
- Venue
- Physiotherapy Theory and Practice
- Publisher
- Informa UK Limited
- Published
- 2008-01
- Volume
- 24
- Issue
- 2
- Pages
- 135-141
- ISSN
- 0959-3985 (ISSN-L)
- 1532-5040
- OpenAlex
- W2000374806
- Cited by
- 166
- References
- 0
- FWCI
- 2.26
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Reliability of inclinometer and goniometric measurements of hip extension flexibility using the modified Thomas test. https://app.cochat.ai/papers/10.1080/09593980701378256
- The paper
- Clapis, P. A., Davis, S. M., & Davis, R. O. (2008). Reliability of inclinometer and goniometric measurements of hip extension flexibility using the modified Thomas test. Physiotherapy Theory and Practice. https://doi.org/10.1080/09593980701378256
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.