The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Clinometric properties of the six-minute walk test in individuals undergoing rehabilitation poststroke
Abstract
The 6-minute walk test (6MWT) is commonly used to measure walking ability. The purpose of this study was to determine the test-retest reliability and concurrent and construct validity of the 6MWT in patients who were actively undergoing inpatient rehabilitation poststroke. Thirty-seven patients undergoing inpatient rehabilitation after a stroke participated; mean age was 66.3 years and mean time since stroke was 33.7 days. Patients underwent two 6MWT trials with 1-3 days between trials. Additional outcome measures taken were gait speed and the Functional Independence Measure (FIM). The 6MWT exhibited high test-retest reliability; ICC(2,1) 0.973 (95% CI=0.925-0.988) and a minimal detectable change (MDC(90)) of 54.1 m. The 6MWT was strongly to moderately correlated with gait speed (r=0.89), locomotion (walk) FIM (r=0.69), and motor FIM (r=0.52). The 6MWT is a clinically useful measure of walking ability poststroke. It is reliable and is related to other measures of walking ability and function that are commonly used during rehabilitation after stroke.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Clinical Gait Assessment in the Neurologically Impaired
Holden, M. K., Gill, K. M., Magliozzi, M. R., Nathan, J., & Piehl-Baker, L. (1984) · Physical Therapy · doi:10.1093/ptj/64.1.35 · Cited by 1,499 · cited 1×
“Gait speed is reliable, with interrater reliability coefficients ranging from 0.95 (Collen, Wade, and Bradshaw, 1990) to 1.00 (Holden et al, 1984) and test-retest reliability coefficients ranging from 0.89 (Wade et al, 1987) to 0.98 (Cunha et al, 2002).”
Influential
Cited by
Body-Weight–Supported Treadmill Rehabilitation after Stroke
Duncan, P. W., Sullivan, K. J., Behrman, A. L., Azen, S. P., Wu, S. S., Nadeau, S. E., Dobkin, B. H., Rose, D. K., Tilson, J. K., Cen, S., et al. (2011) · New England Journal of Medicine · doi:10.1056/nejmoa1010790 · Cited by 652
Tyson, S., & Connell, L. (2009) · Clinical Rehabilitation · doi:10.1177/0269215509339004 · Cited by 364
Predicting Home and Community Walking Activity Poststroke
Fulk, G. D., He, Y., Boyne, P., & Dunning, K. (2017) · Stroke · doi:10.1161/strokeaha.116.015309 · Cited by 306
Self-citationEllis, T., Latham, N. K., DeAngelis, T. R., Thomas, C. A., Saint-Hilaire, M., & Bickmore, T. W. (2013) · American Journal of Physical Medicine & Rehabilitation · doi:10.1097/phm.0b013e31828cd466 · Cited by 91
Step count accuracy and reliability of two activity tracking devices in people after stroke
Schaffer, S. D., Holzapfel, S. D., Fulk, G., & Bosch, P. R. (2017) · Physiotherapy Theory and Practice · doi:10.1080/09593985.2017.1354412 · Cited by 54
Self-citation
Metadata
- Authors
- Fulk, G. D., Echternach, J. L., Nof, L., & O'Sullivan, S.
- Venue
- Physiotherapy Theory and Practice
- Publisher
- Informa UK Limited
- Published
- 2008-01
- Volume
- 24
- Issue
- 3
- Pages
- 195-204
- ISSN
- 0959-3985 (ISSN-L)
- 1532-5040
- OpenAlex
- W2095874049
- Cited by
- 244
- References
- 1
- FWCI
- 8.85
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Clinometric properties of the six-minute walk test in individuals undergoing rehabilitation poststroke. https://app.cochat.ai/papers/10.1080/09593980701588284
- The paper
- Fulk, G. D., Echternach, J. L., Nof, L., & O'Sullivan, S. (2008). Clinometric properties of the six-minute walk test in individuals undergoing rehabilitation poststroke. Physiotherapy Theory and Practice. https://doi.org/10.1080/09593980701588284
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.