Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 246

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Adaptive thermal comfort in Australian school classrooms

de Dear, Richard, Kim, Jungsoo, Candido, Christhina, Deuble, Max·2015·Building Research & Information

Abstract

This survey of thermal comfort in classrooms aimed to define empirically the preferred temperatures, neutral temperatures and acceptable temperature ranges for Australian school children, and to compare them with findings from adult populations. The survey was conducted in a mixture of air-conditioned, evaporative-cooled and naturally ventilated classrooms in nine schools located in three distinct subtropical climate zones during the summer of 2013. A total of 2850 questionnaires were collected from both primary (grade) and secondary (high) schools. An indoor operative temperature of about 22.5°C was found to be the students’ neutral and preferred temperature, which is generally cooler than expected for adults under the same thermal environmental conditions. Despite the lower-than-expected neutrality, the school children demonstrated considerable adaptability to indoor temperature variations, with one thermal sensation unit equating to approximately 4°C operative temperature. Working on the industry-accepted assumption that an acceptable range of indoor operative temperatures corresponds to group mean thermal sensations of −0.85 through to +0.85, the present analysis indicates an acceptable summertime range for Australian students from 19.5 to 26.6°C. The analyses also revealed between-school differences in thermal sensitivity, with students in locations exposed to wider weather variations showing greater thermal adaptability than those in more equable weather districts.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1080/09613218.2015.991627

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

  • Climatic Conditions in Classrooms

    Kevan, S. M., & Howes, J. D. (1980) · Educational Review · doi:10.1080/0013191800320305 · Cited by 10 · cited 1×

    “From their extensive review of the research literature, Mendell and Heath (2005) found that warmer temperatures (above 248C) tend to reduce performance, while colder temperatures (below 228C) reduce manual dexterity and speed (Kevan & Howes, 1980; Levin, 1995; Wyon et al., 1979).”
    Background

Show all 1 references

Cited by

See all 246

Metadata

Authors
de Dear, R., Kim, J., Candido, C., & Deuble, M.
Venue
Building Research & Information
Published
2015-01-08
Volume
43
Issue
3
Pages
383-398
ISSN
  • 0961-3218 (ISSN-L)
  • 1466-4321
OpenAlex
W2041650947
Cited by
246
References
1
FWCI
21.64
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Adaptive thermal comfort in Australian school classrooms. https://app.cochat.ai/papers/10.1080/09613218.2015.991627
The paper
de Dear, R., Kim, J., Candido, C., & Deuble, M. (2015). Adaptive thermal comfort in Australian school classrooms. Building Research & Information. https://doi.org/10.1080/09613218.2015.991627

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.