Adaptive thermal comfort in Australian school classrooms
The DOI matches its Crossref record; 33 of the 33 references it cites were found in a registry or an index.
Abstract
This survey of thermal comfort in classrooms aimed to define empirically the preferred temperatures, neutral temperatures and acceptable temperature ranges for Australian school children, and to compare them with findings from adult populations. The survey was conducted in a mixture of air-conditioned, evaporative-cooled and naturally ventilated classrooms in nine schools located in three distinct subtropical climate zones during the summer of 2013. A total of 2850 questionnaires were collected from both primary (grade) and secondary (high) schools. An indoor operative temperature of about 22.5°C was found to be the students’ neutral and preferred temperature, which is generally cooler than expected for adults under the same thermal environmental conditions. Despite the lower-than-expected neutrality, the school children demonstrated considerable adaptability to indoor temperature variations, with one thermal sensation unit equating to approximately 4°C operative temperature. Working on the industry-accepted assumption that an acceptable range of indoor operative temperatures corresponds to group mean thermal sensations of −0.85 through to +0.85, the present analysis indicates an acceptable summertime range for Australian students from 19.5 to 26.6°C. The analyses also revealed between-school differences in thermal sensitivity, with students in locations exposed to wider weather variations showing greater thermal adaptability than those in more equable weather districts.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
(1998) · eScholarship (California Digital Library) · Cited by 1,934
Mendell, M. J., & Heath, G. A. (2005) · Indoor Air · doi:10.1111/j.1600-0668.2004.00320.x · Cited by 1,034 · cited 4×
“Although Mendell and Heath (2005) provide a comprehensive review of the effects of temperature on student’s classroom performance, several studies, such as those covered by Wyon (1970), were not included.”
BackgroundInfluentialExtension of the PMV model to non-air-conditioned buildings in warm climates
Ole Fanger, P., & Toftum, J. (2002) · Energy and Buildings · doi:10.1016/s0378-7788(02)00003-8 · Cited by 853 · cited 1×
“This stands in stark contrast to the usual pattern observed when adult building occupants’ TSVs are compared with PMV predictions in warm climate zones (Fanger & Toftum, 2002).”
ResultVentilation rates in schools and pupils’ performance
Bakó-Biró, Z., Clements-Croome, D. J., Kochhar, N., Awbi, H. B., & Williams, M. J. (2012) · Building and Environment · doi:10.1016/j.buildenv.2011.08.018 · Cited by 580
Occupational Medicine: State of the Art Reviews
AW, C. (1988) · Occupational Medicine · doi:10.1093/occmed/38.3.90-b · Cited by 537
Indoor environmental quality and pupil perception in Italian primary schools
Giuli, V. D., Pos, O. D., & Carli, M. D. (2012) · Building and Environment · doi:10.1016/j.buildenv.2012.03.024 · Cited by 408 · cited 1×
“…warmer than average, such as those observed in Japan (Kwok & Chun, 2003), Singapore (Wong & Khoo, 2003), and Taiwan (Hwang et al., 2009; Liang et al., 2012), or cooler (Corgnati et al., 2007; De Giuli et al., 2012), the students’ mean thermal sensations were still within the ‘neutral’ category.”
BackgroundOutdoor temperatures and comfort indoors
Humphreys, M. (1978) · Batiment International, Building Research and Practice · doi:10.1080/09613217808550656 · Cited by 377 · cited 4×
“…hypothesis (e.g. de Dear & Brager, 1998; Humphreys, 1978) and previous field studies involving adults in both air-conditioned (AC) or naturally ventilated (NV) environments in similar climates (e.g. Busch, 1992; de Dear, Leow, & Foo, 1991; Humphreys, 1978; Nicol, Raja, Allaudin, & Jamy, 1999).”
BackgroundInfluentialWargocki, P., & Wyon, D. P. (2007) · HVAC&R Research · doi:10.1080/10789669.2007.10390951 · Cited by 364 · cited 4×
“The influence of moderately elevated temperatures on student performance was investigated in a recent series of field experiments conducted in Danish classrooms (Wargocki & Wyon, 2006, 2007).”
BackgroundResultInfluentialThermal comfort in classrooms in the tropics
Wong, N. H., & Khoo, S. S. (2003) · Energy and Buildings · doi:10.1016/s0378-7788(02)00109-3 · Cited by 356 · cited 5×
“Even when the outdoor climatic conditions were considerably warmer than average, such as those observed in Japan (Kwok & Chun, 2003), Singapore (Wong & Khoo, 2003), and Taiwan (Hwang et al., 2009; Liang et al., 2012), or cooler (Corgnati et al., 2007; De Giuli et al., 2012), the students’ mean thermal sensations were…”
BackgroundResultInfluentialOperable windows, personal control and occupant comfort.
Brager, G. S., Paliaga, G., & de Dear, R. (2004) · eScholarship (California Digital Library) · Cited by 347
Teli, D., Jentsch, M. F., & James, P. A. B. (2012) · Energy and Buildings · doi:10.1016/j.enbuild.2012.06.022 · Cited by 284 · cited 4×
“Some ranged from as low as 16–208C in the cooler climates of England (Auliciems, 1969, 1973; Teli et al., 2012), to 248C and 26–278C in subtropical Australia (Auliciems, 1975) and Hawaii (Kwok, 1998) respectively.”
BackgroundInfluentialBusch, J. F. (1992) · Energy and Buildings · doi:10.1016/0378-7788(92)90016-a · Cited by 263 · cited 1×
“…hypothesis (e.g. de Dear & Brager, 1998; Humphreys, 1978) and previous field studies involving adults in both air-conditioned (AC) or naturally ventilated (NV) environments in similar climates (e.g. Busch, 1992; de Dear, Leow, & Foo, 1991; Humphreys, 1978; Nicol, Raja, Allaudin, & Jamy, 1999).”
Corgnati, S. P., Filippi, M., & Viazzo, S. (2005) · Building and Environment · doi:10.1016/j.buildenv.2005.10.027 · Cited by 262 · cited 2×
“, 2012), or cooler (Corgnati et al., 2007; De Giuli et al., 2012), the students’ mean thermal sensations were still within the ‘neutral’ category.”
BackgroundClimatic variations in comfortable temperatures: the Pakistan projects
Nicol, J. F., Raja, I. A., Allaudin, A., & Jamy, G. N. (1999) · Energy and Buildings · doi:10.1016/s0378-7788(99)00011-0 · Cited by 242
Mors, S. T., Hensen, J. L. M., Loomans, M. G. L. C., & Boerstra, A. C. (2011) · Building and Environment · doi:10.1016/j.buildenv.2011.05.025 · Cited by 240 · cited 2×
“…percentage dissatisfied) model underestimate the actual thermal sensation of children, i.e. children have previously been noted to express warmer sensations than predicted by the PMVPPD model (Kwok, 1998; Kwok & Chun, 2003; ter Mors et al., 2011; Wong & Khoo, 2003; Zeiler & Boxem, 2009).”
BackgroundResultde Dear, R. J., Leow, K. G., & Foo, S. C. (1991) · International Journal of Biometeorology · doi:10.1007/bf01041840 · Cited by 229
Self-citationLiang, H.-H., Lin, T., & Hwang, R. (2012) · Applied Energy · doi:10.1016/j.apenergy.2012.02.004 · Cited by 173 · cited 4×
“Even when the outdoor climatic conditions were considerably warmer than average, such as those observed in Japan (Kwok & Chun, 2003), Singapore (Wong & Khoo, 2003), and Taiwan (Hwang et al., 2009; Liang et al., 2012), or cooler (Corgnati et al.”
BackgroundInfluentialThermal comfort in Japanese schools
Kwok, A. G., & Chun, C. (2003) · Solar Energy · doi:10.1016/s0038-092x(03)00147-6 · Cited by 159 · cited 3×
“…percentage dissatisfied) model underestimate the actual thermal sensation of children, i.e. children have previously been noted to express warmer sensations than predicted by the PMVPPD model (Kwok, 1998; Kwok & Chun, 2003; ter Mors et al., 2011; Wong & Khoo, 2003; Zeiler & Boxem, 2009).”
BackgroundResultEffects of thermal activated building systems in schools on thermal comfort in winter
Zeiler, W., & Boxem, G. (2009) · Building and Environment · doi:10.1016/j.buildenv.2009.05.005 · Cited by 153 · cited 2×
“…percentage dissatisfied) model underestimate the actual thermal sensation of children, i.e. children have previously been noted to express warmer sensations than predicted by the PMVPPD model (Kwok, 1998; Kwok & Chun, 2003; ter Mors et al., 2011; Wong & Khoo, 2003; Zeiler & Boxem, 2009).”
BackgroundResultThe effects of moderate heat stress on mental performance.
Wyon, D. P., Andersen, I., & Lundqvist, G. R. (1979) · Scandinavian Journal of Work, Environment & Health · doi:10.5271/sjweh.2646 · Cited by 139 · cited 2×
“From their extensive review of the research literature, Mendell and Heath (2005) found that warmer temperatures (above 248C) tend to reduce performance, while colder temperatures (below 228C) reduce manual dexterity and speed (Kevan & Howes, 1980; Levin, 1995; Wyon et al., 1979).”
BackgroundResultHwang, R., Lin, T., Chen, C., & Kuo, N.-J. (2009) · International Journal of Biometeorology · doi:10.1007/s00484-008-0203-2 · Cited by 127 · cited 4×
“Even when the outdoor climatic conditions were considerably warmer than average, such as those observed in Japan (Kwok & Chun, 2003), Singapore (Wong & Khoo, 2003), and Taiwan (Hwang et al., 2009; Liang et al., 2012), or cooler (Corgnati et al.”
BackgroundInfluentialTemperature and learning: An experimental study.
PEPLER, R. D., & Warner, R. (1968) · ASHRAE winter conference papers · Cited by 109
Havenith, G. (2007) · Ergonomics · doi:10.1080/00140130701587574 · Cited by 109 · cited 2×
“Differences in metabolic rates of children and adults for typical indoor activities may possibly explain the differences in their thermal sensations when exposed to the same temperatures (Havenith, 2007).”
BackgroundA study of the thermal comfort of primary school children in summer
Humphreys, M. (1977) · Building and Environment · doi:10.1016/0360-1323(77)90025-7 · Cited by 84 · cited 1×
“In comparison with adults, children are generally less sensitive to temperature changes (Humphreys, 1977); have a faster rate of heat loss (McCullough, Eckels, & Harms, 2009); and have a greater sensitivity to changes in their core temperature (Anderson & Mekjavic, 1996).”
Research Report on Effects of HVAC on Student Performance
Wyon, D. P., & Wargocki, P. L. (2006) · ASHRAE journal · Cited by 77
Cooling exposure in hot humid climates: are occupants ‘addicted’?
Cândido, C., de Dear, R., Lamberts, R., & Bittencourt, L. (2010) · Architectural Science Review · doi:10.3763/asre.2009.0100 · Cited by 69
Studies of Children under Imposed Noise and Heat Stress
Wyon, D. P. (1970) · Ergonomics · doi:10.1080/00140137008931185 · Cited by 68 · cited 7×
“…concentration, such as coding tests, multiplication problems, short-term memory retention, reading speed and comprehension (Pepler & Warner, 1968; Wyon, 1970; Wyon, Anderson, & Lundqvist, 1979), and the impacts can be both positive and negative, e.g. the speed of multiplication problems was…”
BackgroundResultInfluentialProviding Better Indoor Environmental Quality Brings Economic Benefits
Fisk, W. J., & Seppänen, O. (2007) · University of North Texas Digital Library (University of North Texas) · Cited by 63
Physical factors in the indoor environment.
Levin, H. (1995) · PubMed · Cited by 42
Thermal requirements of secondary schoolchildren in winter
Auliciems, A. (1969) · Journal of Hygiene · doi:10.1017/s0022172400041425 · Cited by 41 · cited 3×
“Some ranged from as low as 16–208C in the cooler climates of England (Auliciems, 1969, 1973; Teli et al., 2012), to 248C and 26–278C in subtropical Australia (Auliciems, 1975) and Hawaii (Kwok, 1998) respectively.”
BackgroundSchoer, L., & Shaffran, J. (1973) · Cited by 30
Climatic Conditions in Classrooms
Kevan, S. M., & Howes, J. D. (1980) · Educational Review · doi:10.1080/0013191800320305 · Cited by 10 · cited 1×
“From their extensive review of the research literature, Mendell and Heath (2005) found that warmer temperatures (above 248C) tend to reduce performance, while colder temperatures (below 228C) reduce manual dexterity and speed (Kevan & Howes, 1980; Levin, 1995; Wyon et al., 1979).”
Background
Cited by
Thermal comfort in educational buildings: A review article
Zomorodian, Z. S., Tahsildoost, M., & Hafezi, M. (2016) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2016.01.033 · Cited by 460
Progress in thermal comfort studies in classrooms over last 50 years and way forward
Singh, M. K., Ooka, R., Rijal, H. B., Kumar, S., Kumar, A., & Mahapatra, S. (2019) · Energy and Buildings · doi:10.1016/j.enbuild.2019.01.051 · Cited by 202
Children's well-being at schools: Impact of climatic conditions and air pollution
Salthammer, T., Uhde, E., Schripp, T., Schieweck, A., Morawska, L., Mazaheri, M., Clifford, S., He, C., Buonanno, G., Querol, X., et al. (2016) · Environment International · doi:10.1016/j.envint.2016.05.009 · Cited by 198
The relationship between classroom temperature and children’s performance in school
Wargocki, P., Porras-Salazar, J. A., & Contreras-Espinoza, S. (2019) · Building and Environment · doi:10.1016/j.buildenv.2019.04.046 · Cited by 189
“…as indicated by this analysis, it can be inferred that the temperature for optimal performance of children in schools might be lower than it is for adults,. TE A plausible explanation is that only a few studies reported any data on learning outcomes around 30°C. Porras-Salazar et al. [6,58].”
BackgroundThe influence of relative humidity on adaptive thermal comfort
Vellei, M., Herrera, M., Fosas, D., & Natarajan, S. (2017) · Building and Environment · doi:10.1016/j.buildenv.2017.08.005 · Cited by 188
“Lower gradients can be associated with more effectively adapted and less sensitive occupants [26].”
Background
Metadata
- Authors
- de Dear, R., Kim, J., Candido, C., & Deuble, M.
- Venue
- Building Research & Information
- Publisher
- Informa UK Limited
- Published
- 2015-01-08
- Volume
- 43
- Issue
- 3
- Pages
- 383-398
- ISSN
- 0961-3218 (ISSN-L)
- 1466-4321
- OpenAlex
- W2041650947
- Cited by
- 246
- References
- 33
- FWCI
- 21.64
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.