CoChat

Development of a novel immunoassay for the iron regulatory peptide hepcidin

Busbridge, M., Griffiths, C., Ashby, D., Gale, D., Jayantha, A., Sanwaiya, A., Chapman, R. S. · 2009 · British Journal of Biomedical Science
Cited by 64

The DOI matches its Crossref record; 15 of the 15 references it cites were found in a registry or an index.

Abstract

To date there have been few published immunoassays for the important iron regulator hepcidin. This study describes a novel competitive radioimmunoassay (RIA) for the bioactive hepcidin peptide. A rabbit anti-hepcidin polyclonal antibody was produced using synthetic hepcidin radiolabelled with 125I to produce a competitive RIA. Normal patient (n=47) samples were collected and assayed for hepcidin to determine a reference range. Other patient groups collected were ulcerative colitis (UC; n=40), iron deficiency anaemia (IDA; n=15), chronic kidney disease not requiring dialysis (CKD; n=45) and chronic kidney disease requiring dialysis (HCKD; n=94). Detection limit of the assay was determined as 0.6 ng/mL. Intra-assay precision was 5 ng/mL (7.2%) and 50 ng/mL (5.8%), interassay precision was 5 ng/mL (7.6%) and 50 ng/mL (6.7%). Analytical recovery was 98% (5 ng/mL), 94% (10 ng/mL) and 97% (50 ng/mL). The assay was linear up to 200 ng/mL. No demonstrable cross-reactivity with human insulin, glucagon I, angiotensinogen I, beta-defensin 1-4, alpha-defensin-1 and plectasin was observed. There was significant correlation (r=0.96, P < or = 0.0001) between the hepcidin RIA and an established hepcidin SELDI-TOF-MS method. Analysis of the normal human samples gave a reference range of 1.1-55 ng/mL for hepcidin. Further statistical evaluation revealed a significant difference between male and female hepcidin levels. There was significant correlation between hepcidin and ferritin in the control group (r=0.6, P < or = 0.0001). There was also a significant difference between the normal and disease groups (P < or = 0.0001). Healthy volunteers (n=10) showed a diurnal increase in plasma hepcidin at 4.00 pm compared to 8.00 am. A robust and optimised immunoassay for bioactive hepcidin has been produced and the patient sample results obtained further validates the important role of hepcidin in iron regulation, and will allow further investigation of this important peptide and its role in iron homeostasis.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1080/09674845.2009.11730263

Cites

15 of 15 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 15 references

Cited by

See all 64

Metadata

Authors
Busbridge, M., Griffiths, C., Ashby, D., Gale, D., Jayantha, A., Sanwaiya, A., & Chapman, R. S.
Venue
British Journal of Biomedical Science
Published
2009-01
Volume
66
Issue
3
Pages
150-157
ISSN
0967-4845 (ISSN-L)
OpenAlex
W135321922
Cited by
64
References
15
FWCI
5.55
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Development of a novel immunoassay for the iron regulatory peptide hepcidin. https://app.cochat.ai/papers/10.1080/09674845.2009.11730263
The paper
Busbridge, M., Griffiths, C., Ashby, D., Gale, D., Jayantha, A., Sanwaiya, A., & Chapman, R. S. (2009). Development of a novel immunoassay for the iron regulatory peptide hepcidin. British Journal of Biomedical Science. https://doi.org/10.1080/09674845.2009.11730263

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.