CoChat

A P300-Based Brain–Computer Interface: Effects of Interface Type and Screen Size

Li, Yueqing, Nam, Chang S., Shadden, Barbara B., Johnson, Steven L. · 2010 · International Journal of Human-Computer Interaction
Cited by 73

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Abstract

As a nonmuscular communication and control system for people with severe motor disabilities, brain–computer interface (BCI) has found several applications. Although a few empirical studies of BCI user performance do exist, little to no research has specifically evaluated the impact of contributing factors on user performance in the BCI applications. To that end, our within-subjects design compared the impact of two different types of interface (ABC interface vs. frequency-based interface) and three levels of screen size (computer monitor, global positioning system, and cell phone screen) of a P300-based BCI application, P300 Speller, on user performance (accuracy, information transfer rate, amplitude, and latency) and usage preference. Ten participants with neuromuscular disabilities such as amyotrophic lateral sclerosis and cerebral palsy and 10 nondisabled participants were asked to type six, 10-character phrases in the P300 Speller. The overall accuracy was 79.7% for the nondisabled participants and 28.7% for participants with motor disabilities. The results showed that interface type and screen size have significant effects on user performance and usage preference, with varying degree of impact to participants with and without motor disabilities. Specifically, participants typed significantly more accurately in frequency-based interface and computer monitor screen. The results of this study should provide invaluable insights to the future research of P300-based BCI applications.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1080/10447318.2011.535753

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

  • Talking off the top of your head: toward a mental prosthesis utilizing event-related brain potentials.

    Farwell, L. A., & Donchin, E. (1988) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(88)90149-6 · Cited by 3,228 · cited 1×

    “Several BCI applications currently exist, allowing users to perform tasks such as writing sentences by selecting letters ( Birbaumer et al, 2000 ; Farewell & Donchin, 1988 ), moving a cursor on a computer screen ( Wolpaw et al, 2000 ), playing an electronic ping-pong game ( Babiloni et al, 2007 ), and controlling an o…”
    Method
  • The thought translation device (TTD) for completely paralyzed patients

    Birbaumer, N., Kubler, A., Ghanayim, N., Hinterberger, T., Perelmouter, J., Kaiser, J., Iversen, I., Kotchoubey, B., Neumann, N., & Flor, H. (2000) · IEEE Transactions on Rehabilitation Engineering · doi:10.1109/86.847812 · Cited by 493 · cited 1×

    “Several BCI applications currently exist, allowing users to perform tasks such as writing sentences by selecting letters (Birbaumer et al., 2000; Farewell & Donchin, 1988), moving a cursor on a computer screen (Wolpaw et al., 2000), playing an electronic ping-pong game (Babiloni et al., 2007), and…”
    Method

Show all 2 references

Cited by

See all 73

Metadata

Authors
Li, Y., Nam, C. S., Shadden, B. B., & Johnson, S. L.
Venue
International Journal of Human-Computer Interaction
Published
2010-12-30
Volume
27
Issue
1
Pages
52-68
ISSN
  • 1044-7318 (ISSN-L)
  • 1532-7590
OpenAlex
W1979323406
Cited by
73
References
2
FWCI
3.26
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: A P300-Based Brain–Computer Interface: Effects of Interface Type and Screen Size. https://app.cochat.ai/papers/10.1080/10447318.2011.535753
The paper
Li, Y., Nam, C. S., Shadden, B. B., & Johnson, S. L. (2010). A P300-Based Brain–Computer Interface: Effects of Interface Type and Screen Size. International Journal of Human-Computer Interaction. https://doi.org/10.1080/10447318.2011.535753

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.