Dermal Measurement and Wipe Sampling Methods: A Review
The DOI matches its Crossref record.
Abstract
Measurement of dermal exposure resulting from contaminants being deposited directly on the skin or a worker physically contacting a contaminated surface is important in the overall assessment of a worker's exposure. Methods developed to measure the quantity of chemical contaminants deposited directly on the skin include the use of exposure patches, clothing, skin swabs, liquid rinses, and tracers. In addition to these direct measures of skin contamination, biological monitoring has been used to indirectly measure dermal exposure. While these methods provide information on the mass of a chemical contaminant that has been deposited on the skin, they fail to provide information about the mass of chemical on a contaminated surface. Currently the most common method used to assess potential exposure from a contaminated surface is wipe sampling. While wipe sampling provides information about the mass of contaminant on a surface, the method suffers from a lack of standardization and fails to relate the mass of contaminant on a surface to the mass transferred to a worker's skin. A review of the methods currently being used for dermal exposure measurement and wipe sampling is presented.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Cohen Hubal, E. A., Sheldon, L. S., Burke, J. M., McCurdy, T. R., Berry, M. R., Rigas, M. L., Zartarian, V. G., & Freeman, N. C. (2000) · Environmental Health Perspectives · doi:10.1289/ehp.108-1638158 · Cited by 392
THE PRACTICE OF EXPOSURE ASSESSMENT: A STATE-OF-THE-ART REVIEW
Paustenbach, D. J. (2000) · Journal of Toxicology and Environmental Health, Part B · doi:10.1080/10937400050045264 · Cited by 296
Dust: a metric for use in residential and building exposure assessment and source characterization.
Lioy, P. J., Freeman, N. C. G., & Millette, J. R. (2002) · Environmental Health Perspectives · doi:10.1289/ehp.02110969 · Cited by 287
Cockroach allergen biology and mitigation in the indoor environment
Gore, J. C., & Schal, C. (2007) · Annual Review of Entomology · doi:10.1146/annurev.ento.52.110405.091313 · Cited by 142
Skin absorption and human risk assessment
Poet, T. S., & McDougal, J. N. (2002) · Chemico-Biological Interactions · doi:10.1016/s0009-2797(02)00013-3 · Cited by 104
Metadata
- Authors
- McArthur, B.
- Venue
- Applied Occupational and Environmental Hygiene
- Publisher
- Informa UK Limited
- Published
- 1992-09
- Volume
- 7
- Issue
- 9
- Pages
- 599-606
- ISSN
- 1047-322X (ISSN-L)
- 1521-0898
- OpenAlex
- W2082306729
- Cited by
- 58
- References
- 0
- FWCI
- 11.70
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Dermal Measurement and Wipe Sampling Methods: A Review. https://app.cochat.ai/papers/10.1080/1047322x.1992.10388051
- The paper
- McArthur, B. (1992). Dermal Measurement and Wipe Sampling Methods: A Review. Applied Occupational and Environmental Hygiene. https://doi.org/10.1080/1047322x.1992.10388051
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.