Continuous PM-10 Measurements Using the Tapered Element Oscillating Microbalance
Open accessThe DOI matches its Crossref record.
Abstract
The goal of continuous ambient participate monitoring has been realized through the use of tapered element oscillating microbalance technology. This technology measures particle mass inertially as the mass deposits on a filter. As such, it is a direct mass measurement and eliminates the mass uncertainties inherent in indirect methods represented by optical or beta adsorption instrumentation. A description of the tapered element oscillating microbalance PM-10 measurement technique is given. Tests have been conducted on tapered element oscillating microbalance PM-10 monitors both in the United States and Europe. Test results presented include comparisons to samplers designated as EPA reference methods.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Visibility: Science and Regulation
Watson, J. G. (2002) · Journal of the Air & Waste Management Association · doi:10.1080/10473289.2002.10470813 · Cited by 929
A review of atmospheric aerosol measurements
McMurry, P. (2000) · Atmospheric Environment · doi:10.1016/s1352-2310(99)00455-0 · Cited by 832
Wang, Y., Yao, L., Wang, L., Liu, Z., Ji, D., Tang, G., Zhang, J., Sun, Y., Hu, B., & Xin, J. (2014) · Science China Earth Sciences · doi:10.1007/s11430-013-4773-4 · Cited by 748
Chow, J. C. (1995) · Journal of the Air & Waste Management Association · doi:10.1080/10473289.1995.10467369 · Cited by 701
Particles, air quality, policy and health
Heal, M. R., Kumar, P., & Harrison, R. M. (2012) · Chemical Society Reviews · doi:10.1039/c2cs35076a · Cited by 693
Physical characterization of particulate emissions from diesel engines: a review
Burtscher, H. (2005) · Journal of Aerosol Science · doi:10.1016/j.jaerosci.2004.12.001 · Cited by 675
PETERS, J. M., AVOL, E., GAUDERMAN, W. J., LINN, W. S., NAVIDI, W., LONDON, S. J., MARGOLIS, H., RAPPAPORT, E., VORA, H., GONG, H., et al. (1999) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.159.3.9804144 · Cited by 518
Pope, C. A., Hansen, M. L., Long, R. W., Nielsen, K. R., Eatough, N. L., Wilson, W. E., & Eatough, D. J. (2004) · Environmental Health Perspectives · doi:10.1289/ehp.6588 · Cited by 505
PETERS, J. M., AVOL, E., NAVIDI, W., LONDON, S. J., GAUDERMAN, W. J., LURMANN, F., LINN, W. S., MARGOLIS, H., RAPPAPORT, E., GONG, H., et al. (1999) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.159.3.9804143 · Cited by 371
Characterization of Indoor Particle Sources Using Continuous Mass and Size Monitors
Long, C. M., Suh, H. H., & Koutrakis, P. (2000) · Journal of the Air & Waste Management Association · doi:10.1080/10473289.2000.10464154 · Cited by 364
Rissler, J., Vestin, A., Swietlicki, E., Fisch, G., Zhou, J., Artaxo, P., & Andreae, M. O. (2006) · Atmospheric Chemistry and Physics · doi:10.5194/acp-6-471-2006 · Cited by 325
Chemical and physical characterization of emissions from birch wood combustion in a wood stove
Hedberg, E., Kristensson, A., Ohlsson, M., Johansson, C., Johansson, P.-Å., Swietlicki, E., Vesely, V., Wideqvist, U., & Westerholm, R. (2002) · Atmospheric Environment · doi:10.1016/s1352-2310(02)00417-x · Cited by 325
Giechaskiel, B., Maricq, M., Ntziachristos, L., Dardiotis, C., Wang, X., Axmann, H., Bergmann, A., & Schindler, W. (2014) · Journal of Aerosol Science · doi:10.1016/j.jaerosci.2013.09.003 · Cited by 299
Oxygenated and water‐soluble organic aerosols in Tokyo
Kondo, Y., Miyazaki, Y., Takegawa, N., Miyakawa, T., Weber, R. J., Jimenez, J. L., Zhang, Q., & Worsnop, D. R. (2007) · Journal of Geophysical Research: Atmospheres · doi:10.1029/2006jd007056 · Cited by 297
Kristensson, A., Johansson, C., Westerholm, R., Swietlicki, E., Gidhagen, L., Wideqvist, U., & Vesely, V. (2004) · Atmospheric Environment · doi:10.1016/j.atmosenv.2003.10.030 · Cited by 285
Evaluation of the TEOM® Method for Measurement of Ambient Particulate Mass in Urban Areas
Allen, G., Sioutas, C., Koutrakis, P., Reiss, R., Lurmann, F. W., & Roberts, P. T. (1997) · Journal of the Air & Waste Management Association · doi:10.1080/10473289.1997.10463923 · Cited by 273
Gao, Y., Zhang, M., Liu, Z., Wang, L., Wang, P., Xia, X., Tao, M., & Zhu, L. (2015) · Atmospheric Chemistry and Physics · doi:10.5194/acp-15-4279-2015 · Cited by 233
“5 (ThermoScientific: http:// www.thermoscientific.com), which provide a continuous direct mass measurement of particulates by utilizing a tapered element oscillating microbalance (Patashnick and Rupprecht, 1991).”
Liu, Z., Gao, W., Yu, Y., Hu, B., Xin, J., Sun, Y., Wang, L., Wang, G., Bi, X., Zhang, G., et al. (2018) · Atmospheric Chemistry and Physics · doi:10.5194/acp-18-8849-2018 · Cited by 225
“This system was designated by the US Environmental Protection Agency (USEPA) as having a monitoring compliance equivalent to the National Ambient Air Quality standard for particulate matter (Patashnick and Rupprecht, 1991).”
MethodLow-cost sensors as an alternative for long-term air quality monitoring
Liu, X., Jayaratne, R., Thai, P., Kuhn, T., Zing, I., Christensen, B., Lamont, R., Dunbabin, M., Zhu, S., Gao, J., et al. (2020) · Environmental Research · doi:10.1016/j.envres.2020.109438 · Cited by 222
Charron, A., & Harrison, R. M. (2005) · Environmental Science & Technology · doi:10.1021/es050462i · Cited by 215
Delfino, R. J., Zeiger, R. S., Seltzer, J. M., Street, D. H., & McLaren, C. E. (2002) · Environmental Health Perspectives · doi:10.1289/ehp.021100607 · Cited by 208
The effect of outdoor fungal spore concentrations on daily asthma severity.
Delfino, R. J., Zeiger, R. S., Seltzer, J. M., Street, D. H., Matteucci, R. M., Anderson, P. R., & Koutrakis, P. (1997) · Environmental Health Perspectives · doi:10.1289/ehp.97105622 · Cited by 191
Panni, T., Mehta, A. J., Schwartz, J. D., Baccarelli, A. A., Just, A. C., Wolf, K., Wahl, S., Cyrys, J., Kunze, S., Strauch, K., et al. (2016) · Environmental Health Perspectives · doi:10.1289/ehp.1509966 · Cited by 184
A review of experimental techniques for aerosol hygroscopicity studies
Tang, M., Chan, C. K., Li, Y. J., Su, H., Ma, Q., Wu, Z., Zhang, G., Wang, Z., Ge, M., Hu, M., et al. (2019) · Atmospheric Chemistry and Physics · doi:10.5194/acp-19-12631-2019 · Cited by 171
Bressi, M., Sciare, J., Ghersi, V., Bonnaire, N., Nicolas, J. B., Petit, J.-E., Moukhtar, S., Rosso, A., Mihalopoulos, N., & Féron, A. (2013) · Atmospheric Chemistry and Physics · doi:10.5194/acp-13-7825-2013 · Cited by 159
Metadata
- Authors
- Patashnick, H., & Rupprecht, E. G.
- Venue
- Journal of the Air & Waste Management Association
- Publisher
- Informa UK Limited
- Published
- 1991-08
- Volume
- 41
- Issue
- 8
- Pages
- 1079-1083
- ISSN
- 1047-3289 (ISSN-L)
- OpenAlex
- W2034556684
- Cited by
- 398
- References
- 0
- FWCI
- 2.73
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.