The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Evaluation of Mesoporous TCPSi, MCM-41, SBA-15, and TUD-1 Materials as API Carriers for Oral Drug Delivery
Open accessAbstract
The feasibility of four mesoporous materials composed of biocompatible Si (TCPSi) or SiO(2) (MCM-41, SBA-15, and TUD-1) were evaluated for oral drug delivery applications. The main focus was to study the effect of the materials different pore systems (unidirectional/2D/3D) and their pore diameters, pore size distributions, pore volumes on the maximal drug load capacity, and release profiles of a loaded active pharmaceutical ingredient. Ibuprofen was used as the model drug. The total pore volume of the mesoporous solid was the main factor limiting the maximum drug load capacity, with SBA-15 reaching a very high drug load of 1:1 in weight due to its high pore volume. Dissolution experiments were performed in HBSS buffers of pH 5.5, 6.8, and 7.4 to mimic the conditions in the small intestine. At pH 5.5 the dissolution rate of ibuprofen released from the mesoporous carriers was significantly faster compared with the standard bulk ibuprofen (86-63% versus 25% released at 45 min), with the fastest release observed from the 3D pore network of TUD-1 carrier. The utilization of mesoporous carriers diminished the pH dependency of ibuprofen dissolution (pK(a) = 4.42), providing an interesting prospect for the formulation of poorly soluble drug compounds.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Modeling and comparison of dissolution profiles
Costa, P., & Sousa Lobo, J. M. (2001) · European Journal of Pharmaceutical Sciences · doi:10.1016/s0928-0987(01)00095-1 · Cited by 5,509
Cited by
Porous silicon in drug delivery devices and materials☆
ANGLIN, E., CHENG, L., FREEMAN, W., & SAILOR, M. (2008) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2008.03.017 · Cited by 889
Speybroeck, M. V., Barillaro, V., Thi, T. D., Mellaerts, R., Martens, J., Humbeeck, J. V., Vermant, J., Annaert, P., Den Mooter, G. V., & Augustijns, P. (2009) · Journal of Pharmaceutical Sciences · doi:10.1002/jps.21638 · Cited by 270
Mellaerts, R., Jammaer, J. A. G., Van Speybroeck, M., Chen, H., Humbeeck, J. V., Augustijns, P., Van den Mooter, G., & Martens, J. A. (2008) · Langmuir · doi:10.1021/la801161g · Cited by 259
Metadata
- Authors
- Heikkilä, T., Salonen, J., Tuura, J., Kumar, N., Salmi, T., Murzin, D. Y., Hamdy, M. S., Mul, G., Laitinen, L., Kaukonen, A. M., Hirvonen, J., & Lehto, V.-P.
- Venue
- Drug Delivery
- Publisher
- Informa UK Limited
- Published
- 2007-01
- Volume
- 14
- Issue
- 6
- Pages
- 337-347
- ISSN
- 1071-7544 (ISSN-L)
- 1521-0464
- OpenAlex
- W2111718136
- Cited by
- 194
- References
- 1
- FWCI
- 4.57
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Evaluation of Mesoporous TCPSi, MCM-41, SBA-15, and TUD-1 Materials as API Carriers for Oral Drug Delivery. https://app.cochat.ai/papers/10.1080/10717540601098823
- The paper
- Heikkilä, T., Salonen, J., Tuura, J., Kumar, N., Salmi, T., Murzin, D. Y., Hamdy, M. S., Mul, G., Laitinen, L., Kaukonen, A. M., Hirvonen, J., & Lehto, V.-P. (2007). Evaluation of Mesoporous TCPSi, MCM-41, SBA-15, and TUD-1 Materials as API Carriers for Oral Drug Delivery. Drug Delivery. https://doi.org/10.1080/10717540601098823
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.