The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Regulation of Blood Flow in the Microcirculation
Abstract
The regulation of blood flow has rich history of investigation and is exemplified in exercising skeletal muscle by a concerted interaction between striated muscle fibers and their microvascular supply. This review considers blood flow control in light of the regulation of capillary perfusion by and among terminal arterioles, the distribution of blood flow in arteriolar networks according to metabolic and hemodynamic feedback from active muscle fibers, and the balance between peak muscle blood flow and arterial blood pressure by sympathetic nerve activity. As metabolic demand increases, the locus of regulating oxygen delivery to muscle fibers “ascends” from terminal arterioles, through intermediate distributing arterioles, and into the proximal arterioles and feed arteries, which govern total flow into a muscle. At multiple levels, venules are positioned to provide feedback to nearby arterioles regarding the metabolic state of the tissue through the convection and production of vasodilator stimuli. Electrical signals initiated on smooth muscle and endothelial cells can travel rapidly for millimeters through cell‐to‐cell conduction via gap junction channels, rapidly coordinating vasodilator responses that govern the distribution and magnitude of blood flow to active muscle fibers. Sympathetic constriction of proximal arterioles and feed arteries can restrict functional hyperemia while dilation prevails in distal arterioles to promote oxygen extraction. With vasomotor tone reflecting myogenic contraction of smooth muscle cells modulated by flow‐induced vasodilator production by endothelium, the initiation of functional vasodilation and its modulation by shear stress and sympathetic innervation dictate how and where blood flow is distributed in microvascular networks. A remarkable ensemble of signaling pathways underlie the integration of smooth muscle and endothelial cell function in microvascular networks. These pathways are being defined with new insight as novel approaches are applied to understanding the cellular and molecular mechanisms of blood flow control.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Maximal perfusion of skeletal muscle in man.
Andersen, P., & Saltin, B. (1985) · The Journal of Physiology · doi:10.1113/jphysiol.1985.sp015794 · Cited by 1,250
Impaired conduction of vasodilation along arterioles in connexin40-deficient mice
de Wit, C., Roos, F., Bolz, S.-S., Kirchhoff, S., Krüger, O., Willecke, K., & Pohl, U. (2000) · Circulation Research · doi:10.1161/01.res.86.6.649 · Cited by 338
Cited by
Glial regulation of the cerebral microvasculature
Iadecola, C., & Nedergaard, M. (2007) · Nature Neuroscience · doi:10.1038/nn2003 · Cited by 1,153
Hypoxic Modulation of Exogenous Nitrite-Induced Vasodilation in Humans
Maher, A. R., Milsom, A. B., Gunaruwan, P., Abozguia, K., Ahmed, I., Weaver, R. A., Thomas, P., Ashrafian, H., Born, G. V. R., James, P. E., et al. (2008) · Circulation · doi:10.1161/circulationaha.107.719591 · Cited by 210
Hemoglobin, nitric oxide and molecular mechanisms of hypoxic vasodilation
Allen, B. W., Stamler, J. S., & Piantadosi, C. A. (2009) · Trends in Molecular Medicine · doi:10.1016/j.molmed.2009.08.002 · Cited by 165
Hudlicka, O., & Brown, M. D. (2009) · Journal of Vascular Research · doi:10.1159/000226127 · Cited by 150
Sacharidou, A., Stratman, A. N., & Davis, G. E. (2012) · Cells Tissues Organs · doi:10.1159/000331410 · Cited by 90
Metadata
- Authors
- SEGAL, S. S.
- Venue
- Microcirculation
- Publisher
- Wiley
- Published
- 2005-01-02
- Volume
- 12
- Issue
- 1
- Pages
- 33-45
- ISSN
- 1073-9688 (ISSN-L)
- 1549-8719
- OpenAlex
- W2158917424
- Cited by
- 540
- References
- 2
- FWCI
- 56.13
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.