The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Development of a Predictive Optimal Controller for Thermal Energy Storage Systems
Abstract
This paper describes the development and simulation of a predictive optimal controller for thermal energy storage systems. The “optimal” strategy minimizes the cost of operating the cooling plant over the simulation horizon. The particular case of a popular ice storage system (ice-on-coil with internal melt) was investigated in a simulation environment. Various predictor models were analyzed with respect to their performance in forecasting cooling load data and information on ambient conditions (dry-bulb and wet-bulb temperatures). The predictor model provides load and weather information to the optimal controller in discrete time steps. An optimal storage charging and discharging strategy was planned at every time step over a fixed look-ahead time window utilizing newly available information. The first action of the optimal sequence of actions was executed over the next time step and the planning process was repeated at every following time step. The effect of the length of the planning horizon was investigated. It was found that short horizons of one day were only marginally suboptimal relative to one that is optimal over the entire simulation horizon of one week. Various utility rate structures were analyzed to cover a range of potential real-time pricing scenarios. The predictive optimal controller was then compared to conventional control heuristics. In summary, it was found that in the presence of complex rate structures the proposed controller had a significant performance benefit over the conventional controls, while requiring only a simple predictor.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Building Energy Use Prediction and System Identification Using Recurrent Neural Networks
Kreider, J. F., Claridge, D. E., Curtiss, P., Dodier, R., Haberl, J. S., & Krarti, M. (1995) · Journal of Solar Energy Engineering · doi:10.1115/1.2847757 · Cited by 97
Self-citation
Cited by
Theory and applications of HVAC control systems – A review of model predictive control (MPC)
Afram, A., & Janabi-Sharifi, F. (2014) · Building and Environment · doi:10.1016/j.buildenv.2013.11.016 · Cited by 1,310
Shaikh, P. H., Nor, N. B. M., Nallagownden, P., Elamvazuthi, I., & Ibrahim, T. (2014) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2014.03.027 · Cited by 866
Review of building energy modeling for control and operation
Li, X., & Wen, J. (2014) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2014.05.056 · Cited by 629
Supervisory and Optimal Control of Building HVAC Systems: A Review
Wang, S., & Ma, Z. (2008) · HVAC&R Research · doi:10.1080/10789669.2008.10390991 · Cited by 496
Modeling techniques used in building HVAC control systems: A review
Afroz, Z., Shafiullah, G., Urmee, T., & Higgins, G. (2018) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2017.10.044 · Cited by 411
Metadata
- Authors
- Henze, G. P., Dodier, R. H., & Krarti, M.
- Venue
- HVAC&R Research
- Publisher
- Informa UK Limited
- Published
- 1997-07
- Volume
- 3
- Issue
- 3
- Pages
- 233-264
- ISSN
- 1078-9669 (ISSN-L)
- 1938-5587
- OpenAlex
- W1994507273
- Cited by
- 175
- References
- 1
- FWCI
- 7.14
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Development of a Predictive Optimal Controller for Thermal Energy Storage Systems. https://app.cochat.ai/papers/10.1080/10789669.1997.10391376
- The paper
- Henze, G. P., Dodier, R. H., & Krarti, M. (1997). Development of a Predictive Optimal Controller for Thermal Energy Storage Systems. HVAC&R Research. https://doi.org/10.1080/10789669.1997.10391376
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.