Common Faults and Their Impacts for Rooftop Air Conditioners
The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Abstract
This paper identifies important faults and their performance impacts for rooftop air conditioners. The frequencies of occurrence and the relative costs of service for different faults were estimated through analysis of service records. Several of the important and difficult to diagnose refrigeration cycle faults were simulated in the laboratory. Also, the impacts on several performance indices were quantified through transient testing for a range of conditions and fault levels. The transient test results indicated that fault detection and diagnostics could be performed using methods that incorporate steady-state assumptions and models. Furthermore, the fault testing led to a set of generic rules for the impacts of faults on measurements that could be used for fault diagnoses. The average impacts of the faults on cooling capacity and coefficient of performance (COP) were also evaluated. Based upon the results, all of the faults are significant at the levels introduced, and should be detected and diagnosed by an FDD system. The data set obtained during this work was very comprehensive, and was used to design and evaluate the performance of an FDD method (Breuker 1997a) that will be reported in a future paper.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
ASHRAE Handbook—1981 Fundamentals
(1981) · Building Services Engineering Research and Technology · doi:10.1177/014362448100200409 · Cited by 3,403
Rossi, T. M., & Braun, J. E. (1997) · Science and Technology for the Built Environment · doi:10.1080/10789669.1997.10391359 · Cited by 230
Self-citation1989 ASHRAE handbook : Fundamentals
Refrigerating (1977) · Medical Entomology and Zoology · Cited by 170
Failure Detection Diagnostics for Thermofluid Systems
Wagner, J. R., & Shoureshi, R. A. (1992) · Journal of Dynamic Systems Measurement and Control · doi:10.1115/1.2897743 · Cited by 48
Minimizing Operating Costs of Vapor Compression Equipment with Optimal Service Scheduling
Rossi, T. M., & Braun, J. E. (1996) · Science and Technology for the Built Environment · doi:10.1080/10789669.1996.10391330 · Cited by 33
Self-citationEffective diagnosis methods for air-conditioning equipment in telecommunications buildings
Yoshimura, M., & Ito, N. (2003) · International Telecommunications Energy Conference (INTELEC) · doi:10.1109/intlec.1989.88347 · Cited by 21
A fault diagnosis system for district heating and cooling facilities
Kumamaru, T., Utsunomiya, T., Yamada, Y., Iwasaki, Y., Shoda, I., & Obayashi, M. (2002) · Annual Conference of the IEEE Industrial Electronics Society (IECON) · doi:10.1109/iecon.1991.239316 · Cited by 18
Cited by
Katipamula, S., & Brambley, M. R. (2005) · HVAC&R Research · doi:10.1080/10789669.2005.10391123 · Cited by 936
Katipamula, S., & Brambley, M. R. (2005) · HVAC&R Research · doi:10.1080/10789669.2005.10391133 · Cited by 306
Evaluation of the impacts of refrigerant charge on air conditioner and heat pump performance
Kim, W., & Braun, J. E. (2012) · International Journal of Refrigeration · doi:10.1016/j.ijrefrig.2012.06.007 · Cited by 134
Self-citationBell, I. H., & Groll, E. A. (2011) · Applied Thermal Engineering · doi:10.1016/j.applthermaleng.2010.10.019 · Cited by 100
Bellanco, I., Fuentes, E., Vallès, M., & Salom, J. (2021) · Journal of Building Engineering · doi:10.1016/j.jobe.2021.102254 · Cited by 84
Chiller: Performance Deterioration and Maintenance
Firdaus, N., Prasetyo, B. T., & Luciana, T. (2016) · Energy Engineering · doi:10.1080/01998595.2016.11728657 · Cited by 16
Metadata
- Authors
- Breuker, M. S., & Braun, J. E.
- Venue
- HVAC&R Research
- Publisher
- Informa UK Limited
- Published
- 1998-07
- Volume
- 4
- Issue
- 3
- Pages
- 303-318
- ISSN
- 1078-9669 (ISSN-L)
- 1938-5587
- OpenAlex
- W2020237557
- Cited by
- 195
- References
- 7
- FWCI
- 6.85
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.