Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 196

The DOI matches its Crossref record.

Experimental Analysis of Model-Based Predictive Optimal Control for Active and Passive Building Thermal Storage Inventory

Henze, Gregor P., Kalz, Doreen E., Liu, Simeng, Felsmann, Clemens·2005·HVAC&R Research

Abstract

This paper demonstrates model-based predictive optimal control of active and passive building thermal storage inventory in a test facility in real time using time-of-use differentiated electricity prices without demand charges. A novel supervisory controller successfully executed a three-step procedure consisting of (1) short-term weather prediction, (2) optimization of control strategy over the next planning horizon using a calibrated building model, and (3) post-processing of the optimal strategy to yield a control command for the current time step that can be executed in the test facility. All primary and secondary building mechanical systems were effectively orchestrated by the model-based predictive optimal controller in real time while observing comfort and operational constraints. It was determined that even when the optimal controller is given imperfect weather forecasts and when the building model used for planning control strategies does not match the actual building perfectly, measured utility cost savings relative to conventional building operation can be substantial. Central requirements are a facility that lends itself to passive storage utilization and a building model that includes a realistic plant representation. Savings associated with passive building thermal storage inventory proved to be small in this case because the test facility is not an ideal candidate for the investigated control technology. Moreover, the facility's central plant revealed the idiosyncratic behavior that the chiller operation in the ice-making mode was more energy efficient than in the chilled-water mode. Field experimentation is now required in a suitable commercial building with sufficient thermal mass, an active TES system, and a climate conducive to passive storage utilization over a longer testing period to support the laboratory findings presented in this study.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1080/10789669.2005.10391134

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 196

Metadata

Authors
Henze, G. P., Kalz, D. E., Liu, S., & Felsmann, C.
Venue
HVAC&R Research
Published
2005-04
Volume
11
Issue
2
Pages
189-213
ISSN
  • 1078-9669 (ISSN-L)
  • 1938-5587
OpenAlex
W2082104542
Cited by
196
References
0
FWCI
18.98
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Experimental Analysis of Model-Based Predictive Optimal Control for Active and Passive Building Thermal Storage Inventory. https://app.cochat.ai/papers/10.1080/10789669.2005.10391134
The paper
Henze, G. P., Kalz, D. E., Liu, S., & Felsmann, C. (2005). Experimental Analysis of Model-Based Predictive Optimal Control for Active and Passive Building Thermal Storage Inventory. HVAC&R Research. https://doi.org/10.1080/10789669.2005.10391134

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.