Cited by 254Arsenic contamination and mitigationEnvironmental remediation with nanomaterialsAdsorption and biosorption for pollutant removal

A simple and effective arsenic filter based on composite iron matrix: Development and deployment studies for groundwater of Bangladesh

Hussam, Abul, Munir, Abul K. M.·2007·Journal of Environmental Science and Health, Part A

Abstract

Drinking groundwater contaminated with naturally occurring arsenic is a worldwide public health issue. This work describes the research, development and distribution of a filter used by thousands of people in Bangladesh to obtain arsenic-free safe water. The filter removes arsenic species primarily by surface complexation reactions: =FeOH + H(2)AsO(4)(-) --> =FeHAsO(4)(-) + H(2)O (K=10(24)) and =FeOH + HAsO(4)(2-) --> =FeAsO(4)(2-) + H(2)O (K=10(29)) on a specially manufactured composite iron matrix (CIM). The filter water meets WHO and Bangladesh standards, has no breakthrough, works without any chemical treatment (pre- or post-), without regeneration, and without producing toxic wastes. It costs about $40/5 years and produce 20-30 L/hour for daily drinking and cooking need of 1-2 families. The spent material is completely non toxic-solid self contained iron-arsenate cement that does not leach in rainwater. Approved by the Bangladesh Government, about 30,000 SONO filters were deployed all over Bangladesh and continue to provide more than a billion liters of safe drinking water. This innovative filter was also recognized by the National Academy of Engineering-Grainger Challenge Prize for sustainability with the highest award for its affordability, reliability, ease of maintenance, social acceptability, and environmental friendliness, which met or exceeded the local government's guidelines for arsenic removal.

Integrity signals

Registry

Crossref · 10.1080/10934520701567122

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

We couldn’t retrieve this paper’s full text, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • Ferrihydrite, granular ferric hydroxide, and hydrous ferric oxide are the most widely explored iron oxides and hydroxides for removal of arsenic, yielding promising results for both AsIII and AsV removals.

    “Ferrihydrite, granular ferric hydroxide, and hydrous ferric oxide are the most widely explored iron oxides and hydroxides for the removal of As yielding promising results for both AsIII and AsV removals [174, 180–184].”

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Authors
Hussam, A., & Munir, A. K. M.
Affiliations
  • George Mason University (US)
  • b Manob Sakti Unnayan Kendro (MSUK) , Kushtia , Bangladesh
Venue
Journal of Environmental Science and Health, Part A
Published
2007-10-16
Volume
42
Issue
12
Pages
1869-1878
ISSN
  • 1093-4529 (ISSN-L)
  • 1532-4117
OpenAlex
W2163686034
Cited by
254
References
1
Citations by year
2026: 3 · 2025: 8 · 2024: 9 · 2023: 10 · 2022: 11 · 2021: 21 · 2020: 12 · 2019: 8 · 2018: 11 · 2017: 12 · 2016: 17 · 2015: 14 · 2014: 20 · 2013: 25 · 2012: 11
FWCI
10.53
Type
journal article
Language
en
Open access
closed
Locations
  • Journal of Environmental Science and Health Part A (publishedVersion)
  • PubMed (publishedVersion)
Topics
  • Physical Sciences › Environmental Science › Environmental Chemistry › Arsenic contamination and mitigation
  • Physical Sciences › Engineering › Biomedical Engineering › Environmental remediation with nanomaterials
  • Physical Sciences › Environmental Science › Water Science and Technology › Adsorption and biosorption for pollutant removal
Keywords
arsenic removal, drinking water filtration, surface complexation, groundwater contamination, low-cost water filter, Bangladesh
MeSH terms
Arsenic, Bangladesh, Filtration, Iron, Water Pollutants, Chemical, Water Supply, Water Purification

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›