Foreign Body Reaction to Meshes Used for the Repair of Abdominal Wall Hernias
The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Abstract
OBJECTIVE: To investigate the local tissue reactions to meshes that had been removed from humans. DESIGN: Open study SETTING: Surgical department of the technical University, Aachen, Germany. MATERIAL: Samples of 17 non-absorbable meshes (1 polyester, 10 polypropylene, 2 reduced polypropylene, and 4 polytetrafluorethylene, PTFE) and 1 absorbable mesh (polyglactin 910) that had been implanted for repair of abdominal wall defects. INTERVENTIONS: Light and transmission electron microscopy, immunohistochemistry, and histological examination. MAIN OUTCOME MEASURES: Signs of inflammatory response. RESULTS: Light microscopy showed chronic inflammatory tissue reaction, even after years, with pronounced differences among materials. Partial volume of inflammatory cells (%) varied from 32 in polypropylene, to 12 in expanded PTFE, 8 in polyester, and 7 in reduced polypropylene. Formation of connective tissue correlated significantly with the extent of the inflammatory reaction (p<0.01). In meshes implanted for long periods there were still numerous macrophages at the interface between tissue and polypropylene (45%), polyester (45%), expanded PTFE (25%), and reduced polypropylene (22%). There was no difference in time dependent tissue reactions (p = 0.19). CONCLUSION: Inflammation around alloplastic materials used to repair defects in the abdominal wall persists for many years. There was evidence of long term wound complications as a result of persistent foreign body reactions. Further studies are required to evaluate the long term tissue response to these materials.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Classification of biomaterials and their related complications in abdominal wall hernia surgery
Amid, P. K. (1997) · Hernia · doi:10.1007/bf02426382 · Cited by 751
Shrinking of polypropylene mesh in vivo: an experimental study in dogs
Klinge, U., Klosterhalfen, B., Müller, M., Öttinger, A. P., & Schumpelick, V. (2003) · The European Journal of Surgery · doi:10.1080/110241598750005156 · Cited by 308
Modified mesh for hernia repair that is adapted to the physiology of the abdominal wall
Klinge, U., Klosterhalfen, B., Conze, J., Limberg, W., Obolenski, B., Öttinger, A. P., & Schumpelick, V. (2003) · European Journal of Surgery · doi:10.1080/110241598750005138 · Cited by 269
Bellón, J. M., Buján, J., Contreras, L. A., Martín, A. C.-S., & Jurado, F. (1996) · PubMed · Cited by 137
Absorbable versus permanent mesh in abdominal operations.
Tyrell, J., SILBERMAN, H. R., Chandrasoma, P. T., Niland, J., & Shull, J. R. (1989) · PubMed · Cited by 131
[Pathophysiology of the abdominal wall].
Klinge, U., Conze, J., Limberg, W., Brücker, C., Öttinger, A. P., & Schumpelick, V. (1996) · PubMed · Cited by 111
Klinge, U., Conze, J., Klosterhalfen, B., Limberg, W., Obolenski, B., �ttinger, A. P., & Schumpelick, V. (1996) · Langenbeck s Archives of Surgery · doi:10.1007/bf00191312 · Cited by 73
Cited by
Klinge, U., Park, J.-K., & Klosterhalfen, B. (2013) · Pathobiology · doi:10.1159/000348446 · Cited by 1,783
Extracellular matrix-based materials for regenerative medicine
Hussey, G. S., Dziki, J. L., & Badylak, S. F. (2018) · Nature Reviews Materials · doi:10.1038/s41578-018-0023-x · Cited by 844
Bottino, M. C., Thomas, V., Schmidt, G., Vohra, Y. K., Chu, T.-M. G., Kowolik, M. J., & Janowski, G. M. (2012) · Dental Materials · doi:10.1016/j.dental.2012.04.022 · Cited by 753
The Argument for Lightweight Polypropylene Mesh in Hernia Repair
Cobb, W. S., Kercher, K. W., & Heniford, B. T. (2005) · Surgical Innovation · doi:10.1177/155335060501200109 · Cited by 364
Past, Present and Future of Surgical Meshes: A Review
Baylón, K., Rodríguez-Camarillo, P., Elías-Zúñiga, A., Díaz-Elizondo, J., Gilkerson, R., & Lozano, K. (2017) · Membranes · doi:10.3390/membranes7030047 · Cited by 292
Metadata
- Authors
- Klinge, B. K.
- Venue
- The European Journal of Surgery
- Publisher
- Oxford University Press (OUP)
- Published
- 1999-07-21
- Volume
- 165
- Issue
- 7
- Pages
- 665-673
- ISSN
- 1102-4151 (ISSN-L)
- OpenAlex
- W2114315030
- Cited by
- 400
- References
- 7
- FWCI
- 5.19
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.