Effects of Plate Position, Plate Type and Sealing Systems on Real-Time PCR Results
Open accessThe DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Abstract
Real-time PCR has become an important tool for quantitative nucleic acids analysis. By now, a wide rang of real-time PCR instruments, PCR plastic consumables and sealing systems are available. In this study both transparent and white plates were taken to test possible position and plate effects on quantitative PCR results on different real-time platforms: ep realplex (Eppendorf, Hamburg, Germany) and the iQ5 (Bio-Rad, Palo Alto, USA). Heat and adhesive sealing was used to compare sealing systems. Heterogeneity in Ct values was calculated to show possible effects of plate type and sealing system. Heterogeneity in amplification efficiency should show possible positional effects of 96-well plates.White plates showed higher amplification efficiency because of higher fluorescence reflection. This had no significant effect on the PCR efficiency but on the sensitivity of the quantification assay. Constant positional effects concerning wells, columns or rows could not be detected.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“different plastics exhibit substantial differences in fluorescence reflection and sensitivity (60 ).”
From The MIQE guidelines: minimum information for publication of quantitative real-time PCR experiments (2009) · cites this paper as [60]
Citations
Cites
RNA integrity and the effect on the real-time qRT-PCR performance
Fleige, S., & Pfaffl, M. W. (2006) · Molecular Aspects of Medicine · doi:10.1016/j.mam.2005.12.003 · Cited by 1,487
Self-citationDorak, M. T. (2009) · Medical Entomology and Zoology · Cited by 466
Properties of the Reverse Transcription Reaction in mRNA Quantification
Ståhlberg, A., Håkansson, J., Xian, X., Semb, H., & Kubista, M. (2004) · Clinical Chemistry · doi:10.1373/clinchem.2003.026161 · Cited by 409
Mobilization, E. (1989) · Cited by 299
Advances in Real‐Time PCR: Application to Clinical Laboratory Diagnostics
(2005) · Advances in Clinical Chemistry · doi:10.1016/s0065-2423(05)40006-2 · Cited by 164
Inhibition of real-time RT–PCR quantification due to tissue-specific contaminants
Tichopád, A., Didier, A., & Pfaffl, M. W. (2003) · Molecular and Cellular Probes · doi:10.1016/j.mcp.2003.09.001 · Cited by 147
Self-citationSundberg, R., Castensson, A., & Jazin, E. (2005) · Biostatistics · doi:10.1093/biostatistics/kxi045 · Cited by 14
Research works printed but not linked: 3
- Bio-Rad tech note 5266. Improving reliability and reproducibility of real-time PCR reactions sealed with clear films. Bio-Rad Laboratories, 2005, Bulletin 5266.
- Fleige S., 2006, Mol. A. Med. 2006, 27, 126
- 4titude, 2008, FRAMEstar®
Cited by
The MIQE guidelines: minimum information for publication of quantitative real-time PCR experiments
Bustin, S. A., Benes, V., Garson, J. A., Hellemans, J., Huggett, J., Kubista, M., Mueller, R., Nolan, T., Pfaffl, M. W., Shipley, G. L., et al. (2009) · Clinical Chemistry · doi:10.1373/clinchem.2008.112797 · Cited by 16,303
Self-citationShanks, O. C., Sivaganesan, M., Peed, L. A., Kelty, C. A., Blackwood, A. D., Greene, M. R., Noble, R. T., Bushon, R. N., Stelzer, E. A., Kinzelman, J. L., et al. (2011) · Environmental Science & Technology · doi:10.1021/es2031455 · Cited by 83
Quantification noise in single cell experiments
Reiter, M., Kirchner, B., Muller, H., Holzhauer, C., Mann, W., & Pfaffl, M. W. (2011) · Nucleic Acids Research · doi:10.1093/nar/gkr505 · Cited by 54
Self-citationQuantification noise in single cell experiments
Reiter, M., Kirchner, B., Müller, H., Holzhauer, C., Mann, W., & Pfaffl, M. W. (2011) · Nucleic Acids Research · doi:10.1093/nar/gkr1136 · Cited by 31
Self-citationRevealing thermodynamics of DNA origami folding via affine transformations
Majikes, J. M., Patrone, P. N., Schiffels, D., Zwolak, M., Kearsley, A. J., Forry, S. P., & Liddle, J. A. (2020) · Nucleic Acids Research · doi:10.1093/nar/gkaa283 · Cited by 20
Metadata
- Authors
- Reiter, M., & Pfaffl, M. W.
- Affiliations
- Technical University of Munich (DE)
- Corresponding author
- Reiter, M.
- ORCID
- Pfaffl, M.W.
- Venue
- Biotechnology & Biotechnological Equipment
- Publisher
- Informa UK Limited
- Published
- 2008-01
- Volume
- 22
- Issue
- 3
- Pages
- 824-828
- ISSN
- 1310-2818 (ISSN-L)
- 1314-3530
- OpenAlex
- W2163262673
- Cited by
- 14
- References
- 6
- Citations by year
- 2025: 1 · 2023: 2 · 2022: 1 · 2020: 2 · 2018: 1 · 2016: 1
- FWCI
- 0.82
- Type
- journal article
- Language
- en
- Open access
- green
- mediatum.ub.tum.de
- Licence
- other-oa
- Locations
- Biotechnology & Biotechnological Equipment (publishedVersion)
- mediaTUM – the media and publications repository of the Technical University Munich (Technical University Munich) (submittedVersion, other-oa)
- Topics
- Life Sciences › Biochemistry, Genetics and Molecular Biology › Molecular Biology › Molecular Biology Techniques and Applications
- Health Sciences › Health Professions › Medical Laboratory Technology › Clinical Laboratory Practices and Quality Control
- Physical Sciences › Engineering › Biomedical Engineering › Microfluidic and Capillary Electrophoresis Applications
- Keywords
- real-time PCR, plate type, sealing systems, heat sealing, adhesive sealing, amplification efficiency
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Effects of Plate Position, Plate Type and Sealing Systems on Real-Time PCR Results. https://app.cochat.ai/papers/10.1080/13102818.2008.10817561
- The paper
- Reiter, M., & Pfaffl, M. W. (2008). Effects of Plate Position, Plate Type and Sealing Systems on Real-Time PCR Results. Biotechnology & Biotechnological Equipment. https://doi.org/10.1080/13102818.2008.10817561
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.