CoChat

Reliability of using urinary and blood trichloroacetic acid as a biomarker of exposure to chlorinated drinking water disinfection byproducts

Zhang, Weiping, Gabos, Stephan, Schopflocher, Donald, Li, Xing-Fang, Gati, Wendy P., Hrudey, Steve E. · 2009 · Biomarkers
Cited by 26

The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.

Abstract

This study was designed to analyse the reliability of using urinary and blood trichloroacetic acid (TCAA) as a biomarker of exposure. A total of 46 healthy women consumed supplied TCAA-containing tap water for 15 days and provided urine and blood samples for TCAA measurements. The findings revealed that the reliability of measurements was excellent by using measures of TCAA ingestion, blood concentration and urinary excretion (intraclass correlation coefficients (ICC) > 0.75, p < 0.001). Volume of tap water consumption (ICC = 0.69) and creatinine-adjusted urinary concentration (ICC = 0.72) were less reliable. This indicated that the intraindividual variability was small and the interindividual reliability was high by using these measures in this cohort study. Laboratory variability did not significantly contribute to total variance (ICC > 0.95, p < 0.001). Other possible sources of variation such as bathing, showering, dishwashing and physical activities were unlikely to contribute significantly to total variance. For sampling strategies, 1-day blood sampling and 2-day urine sampling are sufficient to achieve reliability for an epidemiological study if a quasi-steady-state TCAA level in the body is reached. The results suggest that TCAA ingestion, TCAA loading in blood and urinary TCAA excretion are reliable measures for use as biomarkers in epidemiological studies.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1080/13547500903079186

Cites

6 of 6 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 6 references

Cited by

See all 26

Metadata

Authors
Zhang, W., Gabos, S., Schopflocher, D., Li, X.-F., Gati, W. P., & Hrudey, S. E.
Venue
Biomarkers
Published
2009-07-07
Volume
14
Issue
6
Pages
355-365
ISSN
  • 1354-750X (ISSN-L)
  • 1366-5804
OpenAlex
W2115798493
Cited by
26
References
6
FWCI
1.57
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Reliability of using urinary and blood trichloroacetic acid as a biomarker of exposure to chlorinated drinking water disinfection byproducts. https://app.cochat.ai/papers/10.1080/13547500903079186
The paper
Zhang, W., Gabos, S., Schopflocher, D., Li, X.-F., Gati, W. P., & Hrudey, S. E. (2009). Reliability of using urinary and blood trichloroacetic acid as a biomarker of exposure to chlorinated drinking water disinfection byproducts. Biomarkers. https://doi.org/10.1080/13547500903079186

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.